    CE01ISSM-RID16-05-PCO2WB000
    Deployment: 5
    5/18/16, 3:44 PM 10/2/16, 8:15 PM

    Suspect data - 53% of the values for pco2_seawater are outside of global ranges.

    By Lori Garzio, on 7/24/19

    CE01ISSM-RID16-05-PCO2WB000
    Deployment: 3
    6/3/15, 5:15 PM 10/7/15, 12:00 AM

    Suspect data - 80% of the values for pco2_seawater are outside of global ranges.

    By Lori Garzio, on 7/24/19

    CE01ISSM-RID16-05-PCO2WB000
    Deployment: 1
    4/17/14, 8:45 PM 8/16/14, 10:30 PM

    Suspect data - 92% of the values for pco2_seawater are nans or outside of global ranges.

    By Lori Garzio, on 7/24/19

    CE01ISSM-RID16-05-PCO2WB000

    There is no pressure variable in the .nc files. This should be a coordinate.

    By Lori Garzio, on 7/24/19

    CE01ISSM-RID16-05-PCO2WB000

    There are no recovered_inst data available for download for any deployment. According to the ingest csvs, the recovered_inst raw data files are available for deployments 1-5 and 9. These files should be ingested or the datasets should be annotated to explain why the recovered_inst data aren't available.

    By Lori Garzio, on 7/24/19

    CE01ISSM-RID16-05-PCO2WB000
    Deployment: 6

    There are no data available for download for this deployment. According to the ingest csv, the instrument failed at deployment. This should be annotated in the system.

    By Lori Garzio, on 7/24/19

    GS01SUMO-RID16-07-NUTNRB000
    Deployment: 2

    Suspect data - 99% of the values for nitrate_concentration are outside of global ranges (too high).

    By Lori Garzio, on 7/23/19

    GS01SUMO-RID16-07-NUTNRB000
    Deployment: 1

    Suspect data - 100% of the values for nitrate_concentration are outside of global ranges (too high).

    By Lori Garzio, on 7/23/19

    GS01SUMO-RID16-07-NUTNRB000

    There is no pressure variable in the .nc files. This should be a coordinate.

    By Lori Garzio, on 7/23/19

    GS01SUMO-SBD11-08-NUTNRB000
    Deployment: 2

    There are several unreasonable values and outliers throughout this deployment.

    By Lori Garzio, on 7/23/19

    GS01SUMO-SBD11-08-NUTNRB000
    Deployment: 1

    Suspect data - 100% of the values for nitrate_concentration are outside of global ranges (too high).

    By Lori Garzio, on 7/23/19

    GS01SUMO-SBD11-08-NUTNRB000

    salinity_corrected_nitrate is all fill values for both deployments. According to the provenance.json file, the temperature and salinity data from the collocated CTD is missing.

    By Lori Garzio, on 7/23/19

    GI01SUMO-RID16-07-NUTNRB000

    There is no pressure variable in the .nc files. This should be a coordinate.

    By Lori Garzio, on 7/23/19

    GI01SUMO-RID16-07-NUTNRB000
    Deployment: 3

    78% of salinity_corrected_nitrate data are fill values or nans for this deployment.

    By Lori Garzio, on 7/23/19

    GI01SUMO-RID16-07-NUTNRB000
    Deployment: 2

    salinity_corrected_nitrate is mostly fill values for this deployment.

    By Lori Garzio, on 7/23/19

    GI01SUMO-SBD11-08-NUTNRB000

    Data generally look suspect for all deployments of this instrument (the ISUS model) because of the prevalence of negative values. The dataset should be annotated if there is a known issue with this instrument to inform users if all or some data should be considered suspect.

    By Lori Garzio, on 7/23/19

    GI01SUMO-SBD11-08-NUTNRB000
    Deployment: 2

    salinity_corrected_nitrate is all fill values for this deployment. According to the provenance.json file, the temperature and salinity data from the collocated CTD is missing.

    By Lori Garzio, on 7/23/19

    GI01SUMO-SBD11-08-NUTNRB000

    There are a lot of unreasonable values and outliers throughout this deployment.

    By Lori Garzio, on 7/23/19

    GI01SUMO-SBD11-08-NUTNRB000
    Deployment: 4

    No data are available for download from deployment 4. According to the ingest csv, telemetered files are available and need to be ingested.

    By Lori Garzio, on 7/23/19

    GA01SUMO-SBD11-08-NUTNRB000

    Data generally look suspect for all deployments of this instrument (the ISUS model) because of the prevalence of negative values. The dataset should be annotated if there is a known issue with this instrument to inform users if all or some data should be considered suspect.

    By Lori Garzio, on 7/23/19