Parameter: bt_pings_per_ensemble

Id
PD1160
Display Name
BT Pings Per Ensemble
Standard Name
Unit
1
Fill Value
0
Precision
Parameter Function
Data Product Identifier
Data Product Type
Data Level
Parameter Function Map
Description

Stores the number of bottom-track pings to average together in each ensemble (BP-command). If BP = 0, the ADCP does not collect bottom-track data. The ADCP automatically ex-tends the ensemble interval (TE) if BP x TP > TE. Scaling: LSD = 1 ping; Range = 0 to 999 pings

Parameter Type
quantity
Value Encoding
uint16