Asset: ATAPL-58322-00004

Type
Sensor
Mobile
0
Description of Equipment
2-Wavelength Fluorometer: FLORD Series D
Manufacturer
WET Labs
Model
ECO Triplet-w
Manufacturer Serial No
1131
Firmware Version
Acquisition Date
10/29/13
Original Cost
$13,013.52
Comments
Deployment Cruise Reference Designator Deployment Number Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
TN-313 RS03AXPS-PC03A-4C-FLORDD303 1 09/27/2014 07/09/2015 ATAPL-69839-001-0103 ATAPL-58322-00004 45.8305 -129.753 190 2609
SKQ201610S RS03AXPS-PC03A-4C-FLORDD303 3 07/14/2016 07/30/2017 ATAPL-69839-001-0103 ATAPL-58322-00004 45.8305 -129.753 190 2609
RR1809 RS01SBPS-PC01A-4C-FLORDD103 5 06/24/2018 06/14/2019 ATAPL-69839-001-0101 ATAPL-58322-00004 44.529 -125.39 195 2906

No notes yet.

Class Asset UID Start Date Serial Name Value Notes
FLORDD ATAPL-58322-00004 10/25/2013 1131 CC_angular_resolution 1.076
FLORDD ATAPL-58322-00004 10/25/2013 1131 CC_dark_counts_cdom 48
FLORDD ATAPL-58322-00004 10/25/2013 1131 CC_dark_counts_chlorophyll_a 54
FLORDD ATAPL-58322-00004 10/25/2013 1131 CC_dark_counts_volume_scatter 54
FLORDD ATAPL-58322-00004 10/25/2013 1131 CC_depolarization_ratio 0.039
FLORDD ATAPL-58322-00004 10/25/2013 1131 CC_measurement_wavelength 700
FLORDD ATAPL-58322-00004 10/25/2013 1131 CC_scale_factor_cdom 0.0903
FLORDD ATAPL-58322-00004 10/25/2013 1131 CC_scale_factor_chlorophyll_a 0.0122
FLORDD ATAPL-58322-00004 10/25/2013 1131 CC_scale_factor_volume_scatter 1.807E-06
FLORDD ATAPL-58322-00004 10/25/2013 1131 CC_scattering_angle 124
FLORDD ATAPL-58322-00004 01/14/2016 1131 CC_angular_resolution 1.076
FLORDD ATAPL-58322-00004 01/14/2016 1131 CC_dark_counts_cdom 40
FLORDD ATAPL-58322-00004 01/14/2016 1131 CC_dark_counts_chlorophyll_a 49
FLORDD ATAPL-58322-00004 01/14/2016 1131 CC_dark_counts_volume_scatter 48
FLORDD ATAPL-58322-00004 01/14/2016 1131 CC_depolarization_ratio 0.039
FLORDD ATAPL-58322-00004 01/14/2016 1131 CC_measurement_wavelength 700
FLORDD ATAPL-58322-00004 01/14/2016 1131 CC_scale_factor_cdom 0.0711
FLORDD ATAPL-58322-00004 01/14/2016 1131 CC_scale_factor_chlorophyll_a 0.0123
FLORDD ATAPL-58322-00004 01/14/2016 1131 CC_scale_factor_volume_scatter 2.059E-06
FLORDD ATAPL-58322-00004 01/14/2016 1131 CC_scattering_angle 124
FLORDD ATAPL-58322-00004 11/08/2017 1131 CC_angular_resolution 1.076
FLORDD ATAPL-58322-00004 11/08/2017 1131 CC_dark_counts_cdom 44
FLORDD ATAPL-58322-00004 11/08/2017 1131 CC_dark_counts_chlorophyll_a 51
FLORDD ATAPL-58322-00004 11/08/2017 1131 CC_dark_counts_volume_scatter 50
FLORDD ATAPL-58322-00004 11/08/2017 1131 CC_depolarization_ratio 0.039
FLORDD ATAPL-58322-00004 11/08/2017 1131 CC_measurement_wavelength 700
FLORDD ATAPL-58322-00004 11/08/2017 1131 CC_scale_factor_cdom 0.0653
FLORDD ATAPL-58322-00004 11/08/2017 1131 CC_scale_factor_chlorophyll_a 0.0129
FLORDD ATAPL-58322-00004 11/08/2017 1131 CC_scale_factor_volume_scatter 2.381E-06
FLORDD ATAPL-58322-00004 11/08/2017 1131 CC_scattering_angle 124
FLORDD ATAPL-58322-00004 09/11/2019 1131 CC_angular_resolution 1.076
FLORDD ATAPL-58322-00004 09/11/2019 1131 CC_dark_counts_cdom 44
FLORDD ATAPL-58322-00004 09/11/2019 1131 CC_dark_counts_chlorophyll_a 53
FLORDD ATAPL-58322-00004 09/11/2019 1131 CC_dark_counts_volume_scatter 47
FLORDD ATAPL-58322-00004 09/11/2019 1131 CC_depolarization_ratio 0.039
FLORDD ATAPL-58322-00004 09/11/2019 1131 CC_measurement_wavelength 700
FLORDD ATAPL-58322-00004 09/11/2019 1131 CC_scale_factor_cdom 0.0648
FLORDD ATAPL-58322-00004 09/11/2019 1131 CC_scale_factor_chlorophyll_a 0.0124
FLORDD ATAPL-58322-00004 09/11/2019 1131 CC_scale_factor_volume_scatter 1.872E-06
FLORDD ATAPL-58322-00004 09/11/2019 1131 CC_scattering_angle 124