Asset: CGINS-FLORTJ-01207

Type
Sensor
Mobile
0
Description of Equipment
3-Wavelength Fluorometer: FLORT Series J
Manufacturer
WET Labs
Model
ECO Triplet-w
Manufacturer Serial No
BBFL2W-1207
Firmware Version
Acquisition Date
6/16/14
Original Cost
$13,013.52
Comments
Deployment Cruise Reference Designator Deployment Number Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
OC1503D CE06ISSP-SP001-08-FLORTJ000 1 04/10/2015 07/08/2015 CGMCE-06ISSP-00001 CGVEH-CSPPCE-00003 CGINS-FLORTJ-01207 47.1348 -124.273 29 29
EK-1507 CE01ISSP-SP001-08-FLORTJ000 3 07/17/2015 08/13/2015 CGMCE-01ISSP-00003 CGVEH-CSPPCE-00003 CGINS-FLORTJ-01207 44.6483 -124.098 25 25
OC1404B CE01ISSP-SP001-08-FLORTJ000 4 08/14/2015 10/15/2015 CGMCE-01ISSP-00004 CGVEH-CSPPCE-00003 CGINS-FLORTJ-01207 44.656 -124.095 25 25
SKQ201704S CE07SHSP-SP001-07-FLORTJ000 3 04/16/2017 05/18/2017 CGMCE-07SHSP-00003 CGVEH-CSPPCE-00002 CGINS-FLORTJ-01207 46.9861 -124.566 87 87
PS201804A CE01ISSP-SP001-08-FLORTJ000 9 04/20/2018 05/03/2018 CGMCE-01ISSP-00009 CGVEH-CSPPCE-00002 CGINS-FLORTJ-01207 44.654 -124.095 25 25
ML201805B CE01ISSP-SP001-08-FLORTJ000 10 05/10/2018 07/16/2018 CGMCE-01ISSP-00010 CGVEH-CSPPCE-00002 CGINS-FLORTJ-01207 44.6557 -124.093 25 25
OC1905C CE06ISSP-SP001-08-FLORTJ000 10 05/06/2019 08/27/2019 CGMCE-06ISSP-00010 CGVEH-CSPPCE-00002 CGINS-FLORTJ-01207 47.1334 -124.27 29 29
SKQ201921S CE02SHSP-SP001-07-FLORTJ000 16 10/22/2019 11/01/2019 CGMCE-02SHSP-00016 CGVEH-CSPPCE-00002 CGINS-FLORTJ-01207 44.638 -124.303 80 80

No notes yet.

Class Asset UID Start Date Serial Name Value Notes
FLORTJ CGINS-FLORTJ-01207 05/30/2014 BBFL2W-1207 CC_angular_resolution 1.076 X (Chi) factor for high angular resolution.
FLORTJ CGINS-FLORTJ-01207 05/30/2014 BBFL2W-1207 CC_dark_counts_cdom 41 Measured signal output of fluormeter in clean water with black tape over the detector [counts]
FLORTJ CGINS-FLORTJ-01207 05/30/2014 BBFL2W-1207 CC_dark_counts_chlorophyll_a 50 Measured signal output of fluormeter in clean water with black tape over the detector [counts]
FLORTJ CGINS-FLORTJ-01207 05/30/2014 BBFL2W-1207 CC_dark_counts_volume_scatter 46 Measured signal output of fluormeter in clean water with black tape over the detector [counts]
FLORTJ CGINS-FLORTJ-01207 05/30/2014 BBFL2W-1207 CC_depolarization_ratio 0.039 Depolarization ratio [unitless].
FLORTJ CGINS-FLORTJ-01207 05/30/2014 BBFL2W-1207 CC_measurement_wavelength 700 Optical backscatter measurement wavelength [nm].
FLORTJ CGINS-FLORTJ-01207 05/30/2014 BBFL2W-1207 CC_scale_factor_cdom 0.0904 Multiplier [ppb counts^-1]
FLORTJ CGINS-FLORTJ-01207 05/30/2014 BBFL2W-1207 CC_scale_factor_chlorophyll_a 0.0121 Multiplier [ug L^-1 counts^-1]
FLORTJ CGINS-FLORTJ-01207 05/30/2014 BBFL2W-1207 CC_scale_factor_volume_scatter 3.016E-06 Multiplier [m^-1 sr^-1 counts^-1]
FLORTJ CGINS-FLORTJ-01207 05/30/2014 BBFL2W-1207 CC_scattering_angle 124 Optical backscatter scattering angle [degrees].
FLORTJ CGINS-FLORTJ-01207 07/14/2016 BBFL2W-1207 CC_angular_resolution 1.076 Erroneously named constant; this coefficient scales the particulate scattering at 124 degrees to total backscatter from particles
FLORTJ CGINS-FLORTJ-01207 07/14/2016 BBFL2W-1207 CC_dark_counts_cdom 46 date in filename comes from factory characterization sheet
FLORTJ CGINS-FLORTJ-01207 07/14/2016 BBFL2W-1207 CC_dark_counts_chlorophyll_a 54
FLORTJ CGINS-FLORTJ-01207 07/14/2016 BBFL2W-1207 CC_dark_counts_volume_scatter 51 not 61 as in devfile
FLORTJ CGINS-FLORTJ-01207 07/14/2016 BBFL2W-1207 CC_depolarization_ratio 0.039 Constant
FLORTJ CGINS-FLORTJ-01207 07/14/2016 BBFL2W-1207 CC_measurement_wavelength 700 [nm]; Constant
FLORTJ CGINS-FLORTJ-01207 07/14/2016 BBFL2W-1207 CC_scale_factor_cdom 0.0874
FLORTJ CGINS-FLORTJ-01207 07/14/2016 BBFL2W-1207 CC_scale_factor_chlorophyll_a .0122
FLORTJ CGINS-FLORTJ-01207 07/14/2016 BBFL2W-1207 CC_scale_factor_volume_scatter 2.995e-06
FLORTJ CGINS-FLORTJ-01207 07/14/2016 BBFL2W-1207 CC_scattering_angle 124 [degrees]; Constant
FLORTJ CGINS-FLORTJ-01207 01/26/2018 BBFL2W-1207 CC_angular_resolution 1.076 Erroneously named constant; this coefficient scales the particulate scattering at 124 degrees to total backscatter from particles
FLORTJ CGINS-FLORTJ-01207 01/26/2018 BBFL2W-1207 CC_dark_counts_cdom 45 date in filename comes from dev file
FLORTJ CGINS-FLORTJ-01207 01/26/2018 BBFL2W-1207 CC_dark_counts_chlorophyll_a 49
FLORTJ CGINS-FLORTJ-01207 01/26/2018 BBFL2W-1207 CC_dark_counts_volume_scatter 52
FLORTJ CGINS-FLORTJ-01207 01/26/2018 BBFL2W-1207 CC_depolarization_ratio 0.039 Constant
FLORTJ CGINS-FLORTJ-01207 01/26/2018 BBFL2W-1207 CC_measurement_wavelength 700 [nm]; Constant
FLORTJ CGINS-FLORTJ-01207 01/26/2018 BBFL2W-1207 CC_scale_factor_cdom 0.0877
FLORTJ CGINS-FLORTJ-01207 01/26/2018 BBFL2W-1207 CC_scale_factor_chlorophyll_a .0128
FLORTJ CGINS-FLORTJ-01207 01/26/2018 BBFL2W-1207 CC_scale_factor_volume_scatter 3.153e-06
FLORTJ CGINS-FLORTJ-01207 01/26/2018 BBFL2W-1207 CC_scattering_angle 124 [degrees]; Constant