Asset: CGINS-FLORTK-01030

Type
Sensor
Mobile
0
Description of Equipment
3-Wavelength Fluorometer: FLORT Series K
Manufacturer
WET Labs
Model
ECO Triplet
Manufacturer Serial No
1030
Firmware Version
Acquisition Date
4/26/13
Original Cost
$0.00
Comments
Deployment Cruise Reference Designator Deployment Number Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
OC1404B CE09OSPM-WFP01-04-FLORTK000 1 04/19/2014 08/15/2014 CGMCE-09OSPM-00001 CGVEH-CWFPCE-99103 CGINS-FLORTK-01030 46.8517 -124.971 536 536
OC1503D CE09OSPM-WFP01-04-FLORTK000 3 04/06/2015 10/16/2015 CGMCE-09OSPM-00003 CGVEH-CWFPCE-99103 CGINS-FLORTK-01030 46.8517 -124.967 542 542
TN-342 CE09OSPM-WFP01-04-FLORTK000 5 05/12/2016 09/21/2016 CGMCE-09OSPM-00005 CGVEH-CWFPCE-99103 CGINS-FLORTK-01030 46.8513 -124.982 542 542
SKQ201704S CE09OSPM-WFP01-04-FLORTK000 7 04/12/2017 10/03/2017 CGMCE-09OSPM-00007 CGVEH-CWFPCE-99103 CGINS-FLORTK-01030 46.8526 -124.977 533 533

No notes yet.

Class Asset UID Start Date Serial Name Value Notes
FLORTK CGINS-FLORTK-01030 12/11/2012 1030 CC_angular_resolution 1.076
FLORTK CGINS-FLORTK-01030 12/11/2012 1030 CC_dark_counts_cdom 49.0
FLORTK CGINS-FLORTK-01030 12/11/2012 1030 CC_dark_counts_chlorophyll_a 51.0
FLORTK CGINS-FLORTK-01030 12/11/2012 1030 CC_dark_counts_volume_scatter 50.0
FLORTK CGINS-FLORTK-01030 12/11/2012 1030 CC_depolarization_ratio 0.039
FLORTK CGINS-FLORTK-01030 12/11/2012 1030 CC_measurement_wavelength 700.0
FLORTK CGINS-FLORTK-01030 12/11/2012 1030 CC_scale_factor_cdom 0.0904
FLORTK CGINS-FLORTK-01030 12/11/2012 1030 CC_scale_factor_chlorophyll_a 0.0121
FLORTK CGINS-FLORTK-01030 12/11/2012 1030 CC_scale_factor_volume_scatter 3.481e-06
FLORTK CGINS-FLORTK-01030 12/11/2012 1030 CC_scattering_angle 124.0
FLORTK CGINS-FLORTK-01030 10/05/2014 1030 CC_angular_resolution 1.076
FLORTK CGINS-FLORTK-01030 10/05/2014 1030 CC_dark_counts_cdom 49.0
FLORTK CGINS-FLORTK-01030 10/05/2014 1030 CC_dark_counts_chlorophyll_a 51.0
FLORTK CGINS-FLORTK-01030 10/05/2014 1030 CC_dark_counts_volume_scatter 50.0
FLORTK CGINS-FLORTK-01030 10/05/2014 1030 CC_depolarization_ratio 0.039
FLORTK CGINS-FLORTK-01030 10/05/2014 1030 CC_measurement_wavelength 700.0
FLORTK CGINS-FLORTK-01030 10/05/2014 1030 CC_scale_factor_cdom 0.0904
FLORTK CGINS-FLORTK-01030 10/05/2014 1030 CC_scale_factor_chlorophyll_a 0.0121
FLORTK CGINS-FLORTK-01030 10/05/2014 1030 CC_scale_factor_volume_scatter 3.62e-06
FLORTK CGINS-FLORTK-01030 10/05/2014 1030 CC_scattering_angle 124.0
FLORTK CGINS-FLORTK-01030 12/04/2014 1030 CC_angular_resolution 1.076 chi factor
FLORTK CGINS-FLORTK-01030 12/04/2014 1030 CC_dark_counts_cdom 48.0
FLORTK CGINS-FLORTK-01030 12/04/2014 1030 CC_dark_counts_chlorophyll_a 49.0
FLORTK CGINS-FLORTK-01030 12/04/2014 1030 CC_dark_counts_volume_scatter 48.0
FLORTK CGINS-FLORTK-01030 12/04/2014 1030 CC_depolarization_ratio 0.039
FLORTK CGINS-FLORTK-01030 12/04/2014 1030 CC_measurement_wavelength 700.0
FLORTK CGINS-FLORTK-01030 12/04/2014 1030 CC_scale_factor_cdom 0.0831
FLORTK CGINS-FLORTK-01030 12/04/2014 1030 CC_scale_factor_chlorophyll_a 0.0119
FLORTK CGINS-FLORTK-01030 12/04/2014 1030 CC_scale_factor_volume_scatter 3.233e-06
FLORTK CGINS-FLORTK-01030 12/04/2014 1030 CC_scattering_angle 124.0
FLORTK CGINS-FLORTK-01030 12/16/2015 1030 CC_angular_resolution 1.076 chi factor
FLORTK CGINS-FLORTK-01030 12/16/2015 1030 CC_dark_counts_cdom 48.0
FLORTK CGINS-FLORTK-01030 12/16/2015 1030 CC_dark_counts_chlorophyll_a 48.0
FLORTK CGINS-FLORTK-01030 12/16/2015 1030 CC_dark_counts_volume_scatter 48.0
FLORTK CGINS-FLORTK-01030 12/16/2015 1030 CC_depolarization_ratio 0.039
FLORTK CGINS-FLORTK-01030 12/16/2015 1030 CC_measurement_wavelength 700.0
FLORTK CGINS-FLORTK-01030 12/16/2015 1030 CC_scale_factor_cdom 0.0699
FLORTK CGINS-FLORTK-01030 12/16/2015 1030 CC_scale_factor_chlorophyll_a 0.0121
FLORTK CGINS-FLORTK-01030 12/16/2015 1030 CC_scale_factor_volume_scatter 3.308e-06
FLORTK CGINS-FLORTK-01030 12/16/2015 1030 CC_scattering_angle 124.0
FLORTK CGINS-FLORTK-01030 12/06/2016 1030 CC_angular_resolution 1.076 Erroneously named constant; this coefficient scales the particulate scattering at 124 degrees to total backscatter from particles
FLORTK CGINS-FLORTK-01030 12/06/2016 1030 CC_dark_counts_cdom 47 date in filename comes from factory characterization sheet
FLORTK CGINS-FLORTK-01030 12/06/2016 1030 CC_dark_counts_chlorophyll_a 47
FLORTK CGINS-FLORTK-01030 12/06/2016 1030 CC_dark_counts_volume_scatter 48
FLORTK CGINS-FLORTK-01030 12/06/2016 1030 CC_depolarization_ratio 0.039 Constant
FLORTK CGINS-FLORTK-01030 12/06/2016 1030 CC_measurement_wavelength 700 [nm]; Constant
FLORTK CGINS-FLORTK-01030 12/06/2016 1030 CC_scale_factor_cdom 0.0650
FLORTK CGINS-FLORTK-01030 12/06/2016 1030 CC_scale_factor_chlorophyll_a 0.0116
FLORTK CGINS-FLORTK-01030 12/06/2016 1030 CC_scale_factor_volume_scatter 3.437E-06
FLORTK CGINS-FLORTK-01030 12/06/2016 1030 CC_scattering_angle 124 [degrees]; Constant