Data Stream Report

Instrument Name
Single Point Velocity Meter
Reference Designator
CE06ISSM-RID16-04-VELPTA000
Method
recovered_host
Stream
velpt_ab_instrument_metadata_recovered
Stream Type
Engineering
Stream Content
Metadata
Uframe Route
Driver
Parser

Annotations

No annotations yet.

Parameters

Id Parameter Display Name Standard Name Unit Fill Value Precision Identifier Type Level
PD7 time Time, UTC time seconds since 1900-01-01 -9999999
PD10 port_timestamp Port Timestamp, UTC seconds since 1900-01-01 -9999999
PD11 driver_timestamp Driver Timestamp, UTC seconds since 1900-01-01 -9999999
PD12 internal_timestamp Internal Timestamp, UTC seconds since 1900-01-01 -9999999
PD16 preferred_timestamp Preferred Timestamp 1 empty
PD93 date_time_string Date and Time String 1 empty
PD113 firmware_version Firmware Version 1 empty
PD461 instrmt_type_serial_number Instrument Type and Serial Number 1 empty
PD465 pic_version PIC Code Version Number 1 -9999
PD466 hardware_revision Hardware Revision 1 -9999
PD467 recorder_size Recorder Size (*65536 Bytes) bytes -9999
PD468 velocity_range Velocity Range 1 -99
PD470 pressure_sensor Pressure Sensor 1 -99
PD471 magnetometer_sensor Magnetometer Sensor 1 -99
PD472 tilt_sensor Tilt Sensor 1 -99
PD473 tilt_sensor_mounting Tilt Sensor Mounting 1 -99
PD474 head_frequency Head Frequency kHz -9999
PD475 head_type Head Type 1 -9999
PD476 head_serial_number Head Serial Number 1 empty
PD478 number_beams Number Beams 1 -9999
PD479 transmit_pulse_length Transmit Pulse Length counts 0
PD480 blanking_distance Blanking Distance counts 0
PD481 receive_length Receive Length counts 0
PD482 time_between_pings Time Between Pings counts 0
PD483 time_between_bursts Time Between Bursts counts 0
PD485 average_interval Average Interval s -9999
PD496 compass_update_rate Compass Update Rate Hz -9999
PD497 coordinate_system Coordinate System 1 -99
PD498 number_cells Number Cells 1 -9999
PD500 measurement_interval Measurement Interval s -9999
PD501 deployment_name Deployment Name 1 empty
PD504 diagnostics_interval Diagnostics Interval s -9999
PD505 use_specified_sound_speed Use Specified Sound Speed 1 -99
PD506 diagnostics_mode_enable Diagnostics Mode Enable 1 -99
PD507 analog_output_enable Analog Output Enable 1 -99
PD508 output_format_nortek Output Format Nortek 1 -99
PD509 scaling Scaling 1 -99
PD510 serial_output_enable Serial Output Enable 1 -99
PD511 stage_enable Stage Enable 1 -99
PD512 analog_power_output Analog Power Output 1 -99
PD513 sound_speed_adjust_factor Sound Speed Adjust Factor m s-1 -9999
PD514 number_diagnostics_samples Number Diagnostics Samples 1 -9999
PD516 number_pings_diagnostic Number Pings Diagnostic 1 -9999
PD520 software_version Software Version 1 -9999
PD533 correlation_threshold Correlation Threshold 1 -9999
PD863 ingestion_timestamp Ingestion Timestamp, UTC seconds since 1900-01-01 -9999
PD2931 number_of_beam_sequences Number of Beam Sequences Per Burst counts -9999
PD2932 number_of_beams_in_diagnostics_mode Number of Beams in Diagnostics Mode counts -9999
PD2933 reserved_bit_easyq Reserved Bit - EasyQ 1 -99