Data Stream Report

Instrument Name
3-D Single Point Velocity Meter
Reference Designator
CE07SHSM-MFD35-01-VEL3DD000
Method
recovered_inst
Stream
vel3d_cd_dcl_user_configuration_recovered
Stream Type
Engineering
Stream Content
Configuration Data
Uframe Route
Ingest.vel3d-cd-dcl_recovered
Driver
vel3d_cd_dcl
Parser

Annotations

No annotations yet.

Parameters

Id Parameter Display Name Standard Name Unit Fill Value Precision Identifier Type Level
PD7 time Time, UTC time seconds since 1900-01-01 -9999999
PD10 port_timestamp Port Timestamp, UTC seconds since 1900-01-01 -9999999
PD11 driver_timestamp Driver Timestamp, UTC seconds since 1900-01-01 -9999999
PD12 internal_timestamp Internal Timestamp, UTC seconds since 1900-01-01 -9999999
PD16 preferred_timestamp Preferred Timestamp 1 empty
PD478 number_beams Number Beams 1 -9999
PD479 transmit_pulse_length Transmit Pulse Length counts 0
PD480 blanking_distance Blanking Distance counts 0
PD481 receive_length Receive Length counts 0
PD482 time_between_pings Time Between Pings counts 0
PD483 time_between_bursts Time Between Bursts counts 0
PD484 number_pings Number of Pings 1 -9999
PD485 average_interval Average Interval s -9999
PD487 profile_type Profile Type 1 -99
PD488 mode_type Mode Type 1 -99
PD489 power_level_tcm1 Power Level Tcm1 1 -99
PD490 power_level_tcm2 Power Level Tcm2 1 -99
PD491 sync_out_position Sync Out Position 1 -99
PD492 sample_on_sync Sample on Sync 1 -99
PD493 start_on_sync Start on Sync 1 -99
PD494 power_level_pcr1 Power Level Pcr1 1 -99
PD495 power_level_pcr2 Power Level Pcr2 1 -99
PD496 compass_update_rate Compass Update Rate Hz -9999
PD497 coordinate_system Coordinate System 1 -99
PD498 number_cells Number Cells 1 -9999
PD499 cell_size Cell Size m -9999
PD500 measurement_interval Measurement Interval s -9999
PD501 deployment_name Deployment Name 1 empty
PD502 wrap_mode Wrap Mode 1 -9999
PD503 deployment_start_time Deployment Start Time 1 -99
PD504 diagnostics_interval Diagnostics Interval s -9999
PD505 use_specified_sound_speed Use Specified Sound Speed 1 -99
PD506 diagnostics_mode_enable Diagnostics Mode Enable 1 -99
PD507 analog_output_enable Analog Output Enable 1 -99
PD508 output_format_nortek Output Format Nortek 1 -99
PD509 scaling Scaling 1 -99
PD510 serial_output_enable Serial Output Enable 1 -99
PD511 stage_enable Stage Enable 1 -99
PD512 analog_power_output Analog Power Output 1 -99
PD513 sound_speed_adjust_factor Sound Speed Adjust Factor m s-1 -9999
PD514 number_diagnostics_samples Number Diagnostics Samples 1 -9999
PD515 number_beams_per_cell Number Beams Per Cell 1 -9999
PD516 number_pings_diagnostic Number Pings Diagnostic 1 -9999
PD517 use_dsp_filter Use Dsp Filter 1 -99
PD518 filter_data_output Filter Data Output 1 -99
PD519 analog_input_address Analog Input Address 1 -9999
PD520 software_version Software Version 1 -9999
PD521 velocity_adjustment_factor Velocity Adjustment Factor 1 -9999
PD522 file_comments File Comments 1 empty
PD523 wave_data_rate Wave Data Rate Hz -99
PD524 wave_cell_position Wave Cell Position 1 -99
PD525 dynamic_position_type Dynamic Position Type 1 -99
PD526 percent_wave_cell_position Percent Wave Cell Position 1 -999999999
PD527 wave_transmit_pulse Wave Transmit Pulse 1 -9999
PD528 fixed_wave_blanking_distance Fixed Wave Blanking Distance counts 0
PD529 wave_measurement_cell_size Wave Measurement Cell Size m 0
PD530 number_diagnostics_per_wave Number Diagnostics Per Wave 1 0
PD531 number_samples_per_burst Number Samples Per Burst 1 0
PD532 analog_scale_factor Analog Scale Factor 1 0
PD533 correlation_threshold Correlation Threshold 1 -9999
PD534 filter_constants Filter Constants 1 empty
PD863 ingestion_timestamp Ingestion Timestamp, UTC seconds since 1900-01-01 -9999
PD1088 transmit_pulse_length_2nd Transmit Pulse Length counts 0