Metadata | Start Date | End Date | Comment |
---|---|---|---|
CE01ISSM-RID16-08-SPKIRB000 Method: telemetered Stream: spkir_abj_dcl_instrument |
4/16/18, 4:45 PM | 9/29/18, 4:30 PM |
The bio-shutter appears to be stuck in the closed position, with no downwelling irradiance being measured during daylight hours. Sensor is marked as Not Operational for the remainder of this deployment.
Id: 1549
By: wingardc
|
Id | Parameter | Display Name | Standard Name | Unit | Fill Value | Precision | Identifier | Type | Level |
---|---|---|---|---|---|---|---|---|---|
PD7 | time | Time, UTC | time | seconds since 1900-01-01 | -9999999 | ||||
PD10 | port_timestamp | Port Timestamp, UTC | seconds since 1900-01-01 | -9999999 | |||||
PD11 | driver_timestamp | Driver Timestamp, UTC | seconds since 1900-01-01 | -9999999 | |||||
PD12 | internal_timestamp | Internal Timestamp, UTC | seconds since 1900-01-01 | -9999999 | |||||
PD16 | preferred_timestamp | Preferred Timestamp | 1 | empty | |||||
PD312 | serial_number | Serial Number | 1 | empty | |||||
PD863 | ingestion_timestamp | Ingestion Timestamp, UTC | seconds since 1900-01-01 | -9999 | |||||
PD1089 | instrument_id | Instrument ID | 1 | empty | |||||
PD1091 | timer | Elapsed Time Since Initialization | s | -9999999 | |||||
PD1092 | sample_delay | Sample Delay | ms | -9999 | |||||
PD1100 | vin_sense | Regulated Supply Voltage | counts | 0 | |||||
PD1101 | va_sense | Analog Rail Voltage | counts | 0 | |||||
PD1102 | internal_temperature | Internal Instrument Temperature | counts | 0 | |||||
PD1103 | frame_counter | Frame Counter | counts | 0 | |||||
PD2228 | passed_checksum | Checksum Result | 1 | -99 | |||||
PD2319 | channel_array | Downwelling Spectral Irradiance Measurement | counts | 0 | SPECTIR_L0 | Unprocessed Data | L0 | ||
PD2605 | dcl_controller_timestamp | DCL Controller Timestamp | 1 | empty | |||||
PD2766 | spkir_abj_cspp_downwelling_vector | Downwelling Spectral Irradiance | µW cm-2 nm-1 | -9999999 | SPECTIR_L1 | Science Data | L1 |