Spectrophotometer

Reference Designator
CE02SHBP-LJ01D-08-OPTAAD106
Review Status
Review Complete
Note
The OPTAA data were run through the automated QC tests, but were not reviewed visually. Plots are provided in the “Review Images” section only for wavelengths on/near 676nm (if the wavelengths are defined in the .nc files).
Depth
80m
Class
OPTAA (Absorption Spectrophotometer)
Make / Model
WET Labs / AC-S

Dataset Reviews Last processed: 9/4/19, 7:14 PM

QC Check Info
Dep. Preferred Method Stream DD FD SG EG Gaps GD TS Rate (s) Pressure Comp. Time Order Valid Data Missing Data Data Comp. Missing Coords. Review
1 streamed optaa_sample 326 310 15 0 0 0 7,768,581 1 80 / 1 2 2 3 Complete
2 streamed optaa_sample 355 167 0 187 0 0 7,782,881 80 / 1 2 2 3 Complete
3 streamed optaa_sample 415 91 2 320 0 0 26,636,145 80 / 1 2 2 3 Complete
4 streamed optaa_sample 293 271 0 0 4 24 4,840,705 80 / 1 2 2 3 Complete
Data Ranges Review Images

Test Notes

  1. unique and ascending not tested
  2. no other streams for comparison
  3. missing: ['pressure']

Data Coverage

Deployment: 1234
optaa_sample 95%47%22%92%

Lat/Lon Differences (km)

Deployment: 1234
1 0.00
2 0.010.00
3 0.010.000.00
4 0.010.000.000.00

System Annotations

Metadata Start Date End Date Comment
CE02SHBP
12/7/14, 2:45 PM 12/15/14, 7:00 PM

Note: PFE down. HVPS1 MOV explosion, 800A breaker tripped, investigation and restoration

Id: 956 By: friedrich.knuth

CE02SHBP
1/7/15, 2:32 AM 1/7/15, 3:06 AM

Note: PNWGP Portland <-> Seattle outage

Id: 955 By: friedrich.knuth

CE02SHBP
1/30/15, 7:00 PM 2/3/15, 7:00 PM

Note: Intermittent partial data loss due to storage drive problems at OTB

Id: 954 By: friedrich.knuth

CE02SHBP
3/21/15, 10:10 AM 3/22/15, 12:20 AM

Note: PNWGP outage due to City of Seattle fiber cable work

Id: 953 By: friedrich.knuth

CE02SHBP
6/12/15, 8:00 PM 6/15/15, 12:30 PM

Note: Network issues due to fire that damaged fibers between Portland and Seattle

Id: 952 By: friedrich.knuth

CE02SHBP
8/28/15, 8:00 PM 8/28/15, 8:30 PM

Note: Outage during major utility power failure in Seattle

Id: 951 By: friedrich.knuth

CE02SHBP
1/7/16, 1:10 AM 1/7/16, 1:52 AM

Note: Four 1-minute outages between Portland and Seattle due to maintenance

Id: 950 By: friedrich.knuth

CE02SHBP
3/10/16, 6:06 PM 3/11/16, 4:30 AM

Note: Fiber break between Portland and Seattle

Id: 949 By: friedrich.knuth

CE02SHBP
5/20/16, 12:33 PM 5/20/16, 2:04 PM

Note: Fiber break between Portland and Pacific City

Id: 948 By: friedrich.knuth

CE02SHBP
7/11/16, 10:53 PM 7/11/16, 11:51 PM

Note: Unexplained loss of power at Pittock Building in Portland

Id: 947 By: friedrich.knuth

CE02SHBP
12/17/16, 1:00 PM 12/17/16, 2:00 PM

Note: Corvalis data center lost power

Id: 946 By: friedrich.knuth

CE02SHBP
12/21/16, 8:50 PM 12/23/16, 7:44 AM

Note: Fiber break in Portland due to train crash

Id: 945 By: friedrich.knuth

CE02SHBP
1/8/17, 2:58 PM 1/8/17, 4:41 PM

Note: Network outage during major Seattle utility power failure

Id: 944 By: friedrich.knuth

CE02SHBP
1/9/17, 1:32 PM 1/9/17, 4:30 PM

Note: Lightning strike in Pacific City led to data interruption through isolation of both cable lines from shore station equipment.

Id: 942 By: friedrich.knuth

CE02SHBP
2/7/17, 8:00 AM 2/7/17, 10:00 AM

Note: Outage during PNWGP 1-hour router-maintenance

Id: 943 By: friedrich.knuth

CE02SHBP
2/15/17, 9:43 AM 2/15/17, 12:16 PM

Note: On Wednesday, February 15, power to the North and South cable lines of the Cabled Array was interrupted and all deployed infrastructure went offline. Power was restored on February 16. No hardware issue subsea was identified.

Id: 941 By: friedrich.knuth

CE02SHBP
1/18/18, 10:00 PM 1/19/18, 2:00 PM

Note: A brief violent storm caused loss of power to both the North and South cable lines and the deployed infrastructure during this time. For more information please contact help@oceanobservatories.org. (Redmine # 13109)

Id: 330 By: friedrich.knuth

CE02SHBP
8/22/18, 1:00 PM 8/24/18, 4:00 PM

On Wednesday Aug 22 2018, an automatic protective shutdown of primary power to the OOI Cabled Array occurred during installation of a new chiller system. Power was restored on Aug 24. Due to loss of power to the Cabled Array marine infrastructure, data were not collected by the instruments.

Id: 1482 By: lgarzio
Flag: not_operational Exclude: No

Review Notes

Metadata Start Date End Date Comment
CE02SHBP-LJ01D-08-OPTAAD106

There is no pressure variable in any of the .nc files. This should be a coordinate.

By Lori Garzio, on 10/3/19

CE02SHBP-LJ01D-08-OPTAAD106

Missing data at the end of deployments 2 and 3 should be annotated.

By Lori Garzio, on 10/3/19

CE02SHBP-LJ01D-08-OPTAAD106

According to Roesler and Barnard (Optical proxy for phytoplankton biomass in the absence of photophysiology: Rethinking the absorption line height, Methods in Oceanography, 2013), “absorption meters are highly prone to biofouling, particularly biofilms which not only attenuate the collimated beam but also impact the scattering properties of the optical surfaces and tubes. In productive coastal waters biofouling can have significant impacts (i.e. 10% of the signal) within one to two weeks”.

By Lori Garzio, on 10/3/19

CE02SHBP-LJ01D-08-OPTAAD106
Deployment: 1

optical_absorption, beam_attenutation, wavelength_a and wavelength_c are all arrays of fill values for this deployment. This should be investigated and annotated.

By Lori Garzio, on 10/3/19

CE02SHBP-LJ01D-08-OPTAAD106
Deployment: 2

Suspect data: 16% of beam_attenuation and 59% of optical_absorption values are NaNs, fill values, or outside of global ranges for this deployment.

By Lori Garzio, on 10/3/19

CE02SHBP-LJ01D-08-OPTAAD106
Deployment: 4

Suspect optical_absorption

By Lori Garzio, on 10/3/19

New Note