Dep. | Preferred Method | Stream | DD | FD | SG | EG | Gaps | GD | TS | Rate (s) | Pressure Comp. | Time Order | Valid Data | Missing Data | Data Comp. | Missing Coords. | Review |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | recovered_host | 162 | 162 | 0 | 0 | 0 | 0 | 34,758 | 1 / | 1 | 1 | Complete | |||||
1 | recovered_host | 162 | 162 | 0 | 0 | 0 | 0 | 34,758 | 1 | 1 / | 1 | 1 | Complete | ||||
2 | recovered_host | 214 | 214 | 0 | 0 | 0 | 0 | 46,053 | 1 / | 1 | 1 | Complete | |||||
2 | recovered_host | 214 | 214 | 0 | 0 | 0 | 0 | 46,053 | 1 | 1 / | 1 | 1 | Complete | ||||
3 | recovered_host | 146 | 146 | 0 | 0 | 0 | 0 | 31,320 | 1 / | 1 | 1 | Complete | |||||
3 | recovered_host | 146 | 146 | 0 | 0 | 0 | 0 | 31,319 | 1 | 1 / | 1 | 1 | Complete | ||||
4 | recovered_host | 206 | 28 | 54 | 123 | 0 | 0 | 6,048 | 1 / | 2 | 1 | 1 | Complete | ||||
4 | recovered_host | 206 | 28 | 54 | 123 | 0 | 0 | 6,048 | 1 | 1 / | 2 | 1 | 1 | Complete | |||
5 | telemetered | 179 | 95 | 0 | 16 | 7 | 72 | 18,198 | 1 / | 1 | 1 | Complete | |||||
5 | telemetered | 179 | 95 | 0 | 16 | 7 | 72 | 18,197 | 1 | 1 / | 1 | 1 | Complete | ||||
6 | recovered_host | 178 | 28 | 68 | 80 | 0 | 0 | 6,048 | 1 / | 2 | 1 | 1 | Complete | ||||
6 | recovered_host | 178 | 28 | 68 | 80 | 0 | 0 | 6,048 | 1 | 1 / | 2 | 1 | 1 | Complete | |||
7 | recovered_host | 180 | 128 | 0 | 43 | 1 | 8 | 25,965 | 1 / | 1 | 1 | Complete | |||||
7 | recovered_host | 180 | 128 | 0 | 43 | 1 | 8 | 25,960 | 1 | 1 / | 1 | 1 | Complete |
Deployment: | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|
53% | |||||||
100% | 100% | 100% | 14% | 16% | 71% | ||
53% | |||||||
100% | 100% | 100% | 14% | 16% | 71% |
Deployment: | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|
1 | 0.00 | ||||||
2 | 0.28 | 0.00 | |||||
3 | 0.44 | 0.22 | 0.00 | ||||
4 | 0.02 | 0.29 | 0.46 | 0.00 | |||
5 | 0.25 | 0.17 | 0.21 | 0.27 | 0.00 | ||
6 | 0.18 | 0.46 | 0.61 | 0.17 | 0.40 | 0.00 | |
7 | 0.27 | 0.10 | 0.17 | 0.29 | 0.08 | 0.44 | 0.00 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered Stream: pco2a_a_dcl_instrument_air |
4/5/15, 1:30 PM | 9/23/15, 11:30 AM |
PCO2A air measurement for the Spring 2015 deployment is considered suspect. Recent investigations have indicated a vendor error in assembly may have pinched closed an internal tube carrying the surface air stream into the sample volume resulting in an erroneous measurement.
Id: 1968
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered Stream: pco2a_a_dcl_instrument_air |
5/5/16, 3:30 PM | 9/27/16, 3:30 PM |
A vendor error in assembly pinched closed an internal tube carrying the surface air stream into the sample volume, resulting in an erroneous measurement. Users should not use the PCO2A air measurement for the Spring 2016 deployment (deployment 03), nor the associated sea-air pCO2 flux estimate.
Id: 1969
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: recovered_host Stream: pco2a_a_dcl_instrument_air_recovered |
5/5/16, 3:30 PM | 9/27/16, 3:30 PM |
A vendor error in assembly pinched closed an internal tube carrying the surface air stream into the sample volume, resulting in an erroneous measurement. Users should not use the PCO2A air measurement for the Spring 2016 deployment (deployment 03), nor the associated sea-air pCO2 flux estimate.
Id: 1974
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered Stream: pco2a_a_dcl_instrument_water |
5/5/16, 3:30 PM | 9/27/16, 3:30 PM |
A vendor error in assembly pinched closed an internal tube carrying the surface air stream into the sample volume, resulting in an erroneous measurement. Users should not use the PCO2A air measurement for the Spring 2016 deployment (deployment 03), nor the associated sea-air pCO2 flux estimate.
Id: 1992
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: recovered_host Stream: pco2a_a_dcl_instrument_water_recovered |
5/5/16, 3:30 PM | 9/27/16, 3:30 PM |
A vendor error in assembly pinched closed an internal tube carrying the surface air stream into the sample volume, resulting in an erroneous measurement. Users should not use the PCO2A air measurement for the Spring 2016 deployment (deployment 03), nor the associated sea-air pCO2 flux estimate.
Id: 1994
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered Stream: pco2a_a_dcl_instrument_air |
4/11/17, 1:30 PM | 10/6/17, 10:30 AM |
A vendor error in assembly pinched closed an internal tube carrying the surface air stream into the sample volume, resulting in an erroneous measurement. Users should not use the PCO2A air measurement for the Spring 2017 deployment (deployment 05), nor the associated sea-air pCO2 flux estimate.
Id: 1970
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: recovered_host Stream: pco2a_a_dcl_instrument_air_recovered |
4/11/17, 1:30 PM | 10/6/17, 10:30 AM |
A vendor error in assembly pinched closed an internal tube carrying the surface air stream into the sample volume, resulting in an erroneous measurement. Users should not use the PCO2A air measurement for the Spring 2017 deployment (deployment 05), nor the associated sea-air pCO2 flux estimate.
Id: 1975
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered Stream: pco2a_a_dcl_instrument_water |
4/11/17, 1:30 PM | 10/6/17, 10:30 AM |
A vendor error in assembly pinched closed an internal tube carrying the surface air stream into the sample volume, resulting in an erroneous measurement. Users should not use the PCO2A air measurement for the Spring 2017 deployment (deployment 05), nor the associated sea-air pCO2 flux estimate.
Id: 1993
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: recovered_host Stream: pco2a_a_dcl_instrument_water_recovered |
4/11/17, 1:30 PM | 10/6/17, 10:30 AM |
A vendor error in assembly pinched closed an internal tube carrying the surface air stream into the sample volume, resulting in an erroneous measurement. Users should not use the PCO2A air measurement for the Spring 2017 deployment (deployment 05), nor the associated sea-air pCO2 flux estimate.
Id: 1995
By: wingardc
|
CE07SHSM |
12/1/17, 9:35 AM | 3/25/18, 3:09 PM |
Data loss due to a power system failure. The mooring stopped receiving power from photo voltaic panel 1 of 4 on Nov-2. By Nov-20, the mooring stopped receiving power from two more solar panels (PV2 & PV4) and one of two wind turbines (WT2). This indicates the Power System Controller (PSC) they connect to is failing. Mooring components will be shut down as the mooring loses the ability to recharge its batteries.
Id: 1237
By: crisien
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered Stream: pco2a_a_dcl_instrument_air |
2/24/19, 3:30 AM | 2/24/19, 6:30 PM |
A HITL review of the data has found unusual, nonrealistic data during this time range. The data during this time range is marked as failed and users should avoid using this data in their analysis.
Id: 1971
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: recovered_host Stream: pco2a_a_dcl_instrument_air_recovered |
2/24/19, 3:30 AM | 2/24/19, 6:30 PM |
A HITL review of the data has found unusual, nonrealistic data during this time range. The data during this time range is marked as failed and users should avoid using this data in their analysis.
Id: 1976
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered Stream: pco2a_a_dcl_instrument_air |
3/4/19, 12:30 PM | 3/5/19, 3:30 AM |
A HITL review of the data has found unusual, nonrealistic data during this time range. The data during this time range is marked as failed and users should avoid using this data in their analysis.
Id: 1972
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: recovered_host Stream: pco2a_a_dcl_instrument_air_recovered |
3/4/19, 12:30 PM | 3/5/19, 3:30 AM |
A HITL review of the data has found unusual, nonrealistic data during this time range. The data during this time range is marked as failed and users should avoid using this data in their analysis.
Id: 1977
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered |
4/24/19, 11:12 AM | 10/12/19, 7:51 PM |
Due to a firmware bug, the sensor zeroing function for correcting the baseline drift over time is not currently saving the updated reference value used to compute the raw CO2 value outputs during the measurements. The sensors are zeroing at the end of the sample cycle when scheduled, but the firmware is not storing the new value. This results in the original zero reference value being used for all measurements and an observable and consistent negative drift in both the air and water CO2 values. The vendor has indicated that the data may be correctable post-recovery, however at this time no such correction algorithm has been provided.
Id: 1687
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered Stream: pco2a_a_dcl_instrument_air |
11/4/19, 11:30 AM | 11/5/19, 8:30 AM |
A HITL review of the data has found unusual, suspect data during this time range. The data during this time range is marked as suspect, and users should exercise caution using this data in their analysis.
Id: 1973
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: recovered_host Stream: pco2a_a_dcl_instrument_air_recovered |
11/4/19, 11:30 AM | 11/5/19, 8:30 AM |
A HITL review of the data has found unusual, suspect data during this time range. The data during this time range is marked as suspect, and users should exercise caution using this data in their analysis.
Id: 1978
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered Stream: pco2a_a_dcl_instrument_water |
11/4/19, 11:30 AM | 11/5/19, 8:30 AM |
A HITL review of the data has found unusual, suspect data during this time range. The data during this time range is marked as suspect, and users should exercise caution using this data in their analysis.
Id: 1979
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: recovered_host Stream: pco2a_a_dcl_instrument_water_recovered |
11/4/19, 11:30 AM | 11/5/19, 8:30 AM |
A HITL review of the data has found unusual, suspect data during this time range. The data during this time range is marked as suspect, and users should exercise caution using this data in their analysis.
Id: 1980
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered |
11/10/19, 2:30 PM | 11/12/19, 3:30 PM |
The data logger port providing power to the instrument showed an over-current error and disabled the instrument. The port had to be power cycled in order to clear the error and restore operations.
Id: 2054
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered |
3/7/20, 2:30 PM | 3/10/20, 4:30 PM |
The instrument suffered a firmware crash and had to be power cycled in order to restore operations. We are in consultation with the vendor to determine the cause of this failure.
Id: 2057
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered |
3/30/20, 8:30 PM | 3/31/20, 7:30 PM |
The instrument suffered a firmware crash and had to be power cycled in order to restore operations. We are in consultation with the vendor to determine the cause of this failure.
Id: 2058
By: wingardc
|
CE07SHSM-SBD12-04-PCO2AA000 Method: telemetered |
4/5/20, 6:30 PM | 4/8/20, 7:30 PM |
The instrument suffered a firmware crash and had to be power cycled in order to restore operations. We are in consultation with the vendor to determine the cause of this failure.
Id: 2059
By: wingardc
|
CE07SHSM Method: telemetered |
5/13/20, 6:40 PM |
Due to a bug in the mooring telemetry system, data during this time range was not telemetered to shore. It was recorded on the mooring and instruments and will be available in the recovered data streams.
Id: 2185
By: wingardc
|
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CE07SHSM-SBD12-04-PCO2AA000 Deployment: 1 |
4/15/15, 5:15 PM | 9/23/15, 3:08 PM | |
CE07SHSM-SBD12-04-PCO2AA000 Deployment: 2 |
3/15/16, 12:00 AM | 5/13/16, 10:15 PM | |
CE07SHSM-SBD12-04-PCO2AA000 Deployment: 3 |
5/5/16, 7:08 PM | 9/27/16, 7:47 PM | |
CE07SHSM-SBD12-04-PCO2AA000 Deployment: 4 |
pco2_co2flux is all fill values for deployments 4 and 6. By Lori Garzio, on 7/31/19 |
||
CE07SHSM-SBD12-04-PCO2AA000 Deployment: 4 |
Missing data for deployment 4 should be annotated. By Lori Garzio, on 7/31/19 |
||
CE07SHSM-SBD12-04-PCO2AA000 Deployment: 5 |
recovered_host data are not available for download for this deployment. According to the ingest csv, the recovered_host raw data files are missing. These files should be provided and ingested. By Lori Garzio, on 7/31/19 |
||
CE07SHSM-SBD12-04-PCO2AA000 Deployment: 5 |
4/11/17, 5:51 PM | 10/6/17, 2:26 PM |