Dep. | Preferred Method | Stream | DD | FD | SG | EG | Gaps | GD | TS | Rate (s) | Pressure Comp. | Time Order | Valid Data | Missing Data | Data Comp. | Missing Coords. | Review |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | recovered_inst | 150 | 149 | 0 | 0 | 0 | 0 | 14,217 | 900 | 455 / 165 | 1 | Complete | |||||
2 | recovered_inst | 168 | 167 | 0 | 0 | 0 | 0 | 16,028 | 900 | 442 / 446 | 1 | Complete | |||||
3 | recovered_inst | 205 | 205 | 0 | 0 | 0 | 0 | 19,575 | 900 | 454 / 465 | 1 | Complete | |||||
4 | recovered_inst | 139 | 96 | 0 | 42 | 0 | 0 | 8,477 | 900 | 446 / 449 | 1 | Complete | |||||
5 | recovered_inst | 240 | 240 | 0 | 0 | 0 | 0 | 22,935 | 900 | 450 / 453 | 1 | Complete | |||||
6 | recovered_inst | 150 | 150 | 0 | 0 | 0 | 0 | 14,301 | 900 | 443 / 465 | 1 | Complete | |||||
7 | recovered_inst | 153 | 153 | 0 | 0 | 0 | 0 | 14,585 | 900 | 452 / 451 | 1 | Complete |
Deployment: | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|
99% | 99% | 100% | 69% | 100% | 100% | 100% |
Deployment: | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|
1 | 0.00 | ||||||
2 | 0.51 | 0.00 | |||||
3 | 0.56 | 0.79 | 0.00 | ||||
4 | 0.49 | 0.12 | 0.85 | 0.00 | |||
5 | 0.58 | 0.82 | 0.03 | 0.88 | 0.00 | ||
6 | 0.46 | 0.20 | 0.88 | 0.08 | 0.91 | 0.00 | |
7 | 0.54 | 0.75 | 0.05 | 0.81 | 0.08 | 0.84 | 0.00 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CP04OSSM-MFD37-03-CTDBPE000 |
12/12/14, 4:47 PM | 5/10/15, 3:57 PM |
Deployment 1: The CTDBP instrument deployed was a Series C which has 100 m strain gauge rather than a Series E which has a 600 m strain gauge pressure sensor. The CTDBP was deployed outside of operational range; pressure data and data products computed using pressure data are incorrect. Id: 1910 By: cdobson |
CP04OSSM-MFD37-03-CTDBPE000 |
12/12/14, 4:47 PM | 5/9/15, 8:00 PM |
Deployment 1: No telemetered or recovered_host data are available. The CTD failed to send data via the Data Concentrator Logger. Id: 762 By: leila |
CP04OSSM-MFD37-03-CTDBPE000 Method: recovered_inst Stream: ctdbp_cdef_instrument_recovered |
12/12/14, 4:47 PM | 5/9/15, 8:00 PM |
Deployment 1: The instrumnt deployment depth is at 450 m. The pressure sensor is in fault.
Id: 763
By: leila
|
CP04OSSM-MFD37-03-CTDBPE000 Method: telemetered Stream: ctdbp_cdef_dcl_instrument |
5/9/15, 3:05 PM | 5/9/15, 10:05 PM |
Deployment 2: Spike in data at beginning of record, presumably recorded in transit to depth.
Id: 748
By: leila
|
CP04OSSM Method: telemetered |
10/22/15, 3:38 PM | 5/13/16, 1:18 PM |
Fuel cell impacted available instrument power, so telemetered data are not available or reliable. Recovered data are available for instruments that could record internally. Id: 1362 By: leila |
CP04OSSM-MFD37 |
10/16/16, 8:00 PM | 4/2/17, 9:00 PM |
No telemetered data are expected because of ground faults on the seafloor Multi-Function Node. Recovered data are available from instruments recording internally. Id: 356 By: leila |
CP04OSSM-MFD37 |
6/28/17, 5:00 AM | 10/29/17, 3:00 AM |
No telemetered data expected because the DSL line has failed. Id: 358 By: leila |
CP04OSSM-MFD37 Method: telemetered |
2/9/18, 1:02 PM | 3/29/18, 8:42 AM |
Deployment 7: Communication with the MFN instruments was disabled due to intermittent communications over the DSL line.
Id: 938
By: leila
|
CP04OSSM-MFD37 Method: telemetered |
5/9/18, 11:00 PM | 10/30/18, 10:30 AM |
Instruments are presently disabled. Note: Instruments may continue to sample using internal batteries and storage cards. Id: 1518 By: leila |
CP04OSSM Method: telemetered |
1/30/19, 10:00 AM | 4/8/19, 7:39 AM |
CP04OSSM D00009 buoy broke free and went adrift on 1/30/2019, 1500UTC. All instruments on the MFN ceased telemetry on 1/30/2019 and instruments on the buoy/NSIF continued to sample through 2/1/2019. No more telemetered data expected for this deployment. Id: 1557 By: cdobson |
CP04OSSM-MFD37 |
5/11/19, 8:00 PM |
Deployment 10: Telemetered data from all MFN instruments could be delayed up to 3 days due to a limitation in communications with the MFN. Id: 1629 By: cdobson |
|
CP04OSSM-MFD37 |
11/14/19, 7:00 PM |
Deployment 11: MFN offline due to high voltage short on 2019-11-15. No telemetered data expected from instruments on the MFN; instruments with external batteries will continue to log internally.
Id: 1820
By: cdobson
|
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CP04OSSM-MFD37-03-CTDBPE000 |
|||
CP04OSSM-MFD37-03-CTDBPE000 Deployment: 1 |
12/12/14, 9:47 PM | 5/10/15, 12:00 AM |
Annotation ID 763: pressure is incorrect for deployment 1. This annotation should also say that conductivity, density and salinity values are wrong. Issue should be investigated. By Lori Garzio, on 3/26/19 |
CP04OSSM-MFD37-03-CTDBPE000 Deployment: 2 |
5/9/15, 1:04 AM | 5/10/15, 12:00 AM |
Annotation ID 748: spike in data record. Excluding from summary data ranges. By Lori Garzio, on 3/26/19 |
CP04OSSM-MFD37-03-CTDBPE000 Deployment: 4 |
8/30/16, 12:00 AM | 10/12/16, 5:12 PM |
The deployment 4 data gap at the end of the data record should be annotated. By Lori Garzio, on 3/26/19 |