Mobile Asset Controller

Reference Designator
GA05MOAS-PG563-00-ENG000000
Review Status
Engineering
Note
Depth
0 to 200m
Class
ENG00 (Mobile Asset Controller)
Make / Model
Teledyne Webb / G2 Slocum Gliders

Dataset Reviews

No reviews found.

Deployment Map

System Annotations

Metadata Start Date End Date Comment
GA05MOAS-PG563
11/24/15, 4:56 PM 1/29/16, 7:00 PM

Deployment 1: The ballast pump developed erratic behavior which progressed to complete pump failure. Early signs of issue seen in late Dec 2015. Glider went adrift, the science sensors were turned off on 1/30/2016 and the glider was recovered on 05/02/2016.

Id: 415 By: lgarzio

Review Notes

Metadata Start Date End Date Comment
GA05MOAS

Glider optodes typically exhibit a sensor lag of 20-25 seconds. Example attached of several segments with consecutive down and up casts for CP05MOAS-GL335-04-DOSTAM000 on 10/26/2015 showing a typical measurement time lag. Profiles should be analyzed for individual time lags and data should be adjusted. OOI doesn't necessarily need to make the adjustment but users should be aware of the issue.

By Lori Garzio, on 5/31/19

New Note