Dep. | Preferred Method | Stream | DD | FD | SG | EG | Gaps | GD | TS | Rate (s) | Pressure Comp. | Time Order | Valid Data | Missing Data | Data Comp. | Missing Coords. | Review |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | recovered_host | flort_m_sample | 161 | 69 | 0 | 67 | 1 | 24 | 380,586 | 1 | 200 / 211 | 1 | 1 | Complete |
Deployment: | 1 |
---|---|
flort_m_sample | 43% |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
GA05MOAS-PG563 |
11/24/15, 4:56 PM | 1/29/16, 7:00 PM |
Deployment 1: The ballast pump developed erratic behavior which progressed to complete pump failure. Early signs of issue seen in late Dec 2015. Glider went adrift, the science sensors were turned off on 1/30/2016 and the glider was recovered on 05/02/2016. Id: 415 By: lgarzio |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
GA05MOAS-PG563-03-FLORTM000 |
Comparison with the shipboard CTD cast was done for D0001. Chl-a recorded by the glider was higher compared to the CTD cast at the surface, and generally matched the CTD cast at depth (~50-100 dbar). Further analysis using the shipboard bottle data should be conducted. This is outside the scope of this project. By Lori Garzio, on 3/8/19 |
||
GA05MOAS |
Glider optodes typically exhibit a sensor lag of 20-25 seconds. Example attached of several segments with consecutive down and up casts for CP05MOAS-GL335-04-DOSTAM000 on 10/26/2015 showing a typical measurement time lag. Profiles should be analyzed for individual time lags and data should be adjusted. OOI doesn't necessarily need to make the adjustment but users should be aware of the issue. By Lori Garzio, on 5/31/19 |
||
GA05MOAS-PG563-03-FLORTM000 Deployment: 1 |