Dep. | Preferred Method | Stream | DD | FD | SG | EG | Gaps | GD | TS | Rate (s) | Pressure Comp. | Time Order | Valid Data | Missing Data | Data Comp. | Missing Coords. | Review |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | recovered_host | flort_o_glider_data | 9 | 8 | 0 | 0 | 0 | 0 | 39,766 | 1 | 200 / 209 | 1 | 1 | Complete |
Deployment: | 1 |
---|---|
flort_o_glider_data | 89% |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
GP05MOAS-PG575 |
6/27/16, 2:58 PM | 7/5/16, 10:52 AM |
Deployment 2: Glider recovered shortly after deployment due to pump anomalies. Id: 592 By: lgarzio |
GP05MOAS-PG575 |
9/29/19, 9:47 PM | 9/30/19, 10:15 AM |
Deployment 2: Glider was temporarily recovered after its first dive to adjust the external ballast and was re-deployed 2019-09-30 14:15UTC. Id: 1765 By: cdobson |
GP05MOAS-PG575 |
4/22/20, 8:00 PM | 6/6/20, 12:10 PM |
Deployment 2: This glider is being flown to the Oregon coast due to the possibility of limited recovery options at the Papa Array this summer. The glider left the array on 2020-04-23 and the science sensors will continue sampling as it flies toward the coast. Id: 2072 By: cdobson |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
GP05MOAS |
Glider optodes typically exhibit a sensor lag of 20-25 seconds. Example attached of several segments with consecutive down and up casts for CP05MOAS-GL335-04-DOSTAM000 on 10/26/2015 showing a typical measurement time lag. Profiles should be analyzed for individual time lags and data should be adjusted. OOI doesn't necessarily need to make the adjustment but users should be aware of the issue. By Lori Garzio, on 5/31/19 |
||
GP05MOAS-PG575-04-FLORTO000 Deployment: 1 |
There are no global ranges in the system for sci_bb3slo_b470_units, flort_o_bback_b470_total, flort_o_bback_b532_total, sci_bb3slo_b660_units, and flort_o_bback_b660_total. By Lori Garzio, on 3/19/20 |
||
GP05MOAS-PG575-04-FLORTO000 Deployment: 1 |
The arrays for the following variables are all NaNs: sci_bb3slo_b470_units, flort_o_bback_b470_total, flort_o_bback_b532_total, sci_bb3slo_b660_units, flort_o_bback_b660_total. According to the provenance.json (attached), the following cal values are missing: CC_1_dark_counts_volume_scatter, CC_1_scale_factor_volume_scatter, CC_1_measurement_wavelength, CC_2_dark_counts_volume_scatter, CC_2_scale_factor_volume_scatter, CC_2_measurement_wavelength, CC_3_dark_counts_volume_scatter, CC_3_scale_factor_volume_scatter, and CC_3_measurement_wavelength. By Lori Garzio, on 3/19/20 |