Seawater pH

Reference Designator
RS01SBPS-PC01A-4B-PHSENA102
Review Status
Review Complete
Note
Depth
200m
Class
PHSEN (Seawater pH)
Make / Model
Sunburst / SAMI-pH

Dataset Reviews Last processed: 6/14/19, 8:33 PM

QC Check Info
Dep. Preferred Method Stream DD FD SG EG Gaps GD TS Rate (s) Pressure Comp. Time Order Valid Data Missing Data Data Comp. Missing Coords. Review
1 streamed phsen_data_record 281 266 3 0 4 12 6,272 3,600 195 / 1 1 2 Complete
2 streamed phsen_data_record 377 365 1 0 4 11 8,570 3,600 195 / 1 1 2 Complete
3 streamed phsen_data_record 376 374 0 0 3 3 8,841 3,600 195 / 1 1 2 Complete
4 streamed phsen_data_record 325 321 0 0 3 4 7,565 3,599 195 / 1 1 2 Complete
Data Ranges Review Images

Test Notes

  1. no other streams for comparison
  2. missing: ['pressure']

Data Coverage

Deployment: 1234
phsen_data_record 95%97%99%99%

Lat/Lon Differences (km)

Deployment: 1234
1 0.00
2 0.080.00
3 0.080.000.00
4 0.080.000.000.00

Example Composite Data Plot

System Annotations

Metadata Start Date End Date Comment
RS01SBPS
12/7/14, 2:45 PM 12/15/14, 7:00 PM

Note: PFE down. HVPS1 MOV explosion, 800A breaker tripped, investigation and restoration

Id: 1248 By: knuth

RS01SBPS
1/7/15, 2:32 AM 1/7/15, 3:06 AM

Note: PNWGP Portland <-> Seattle outage. Possible data gap < 24h.

Id: 1250 By: knuth

RS01SBPS
1/30/15, 7:00 PM 2/3/15, 7:00 PM

Note: Intermittent partial data loss due to storage drive problems at OTB

Id: 1251 By: knuth

RS01SBPS
3/21/15, 10:10 AM 3/22/15, 12:20 AM

Note: PNWGP outage due to City of Seattle fiber cable work. Possible data gap < 24h.

Id: 1256 By: knuth

RS01SBPS
6/12/15, 8:00 PM 6/15/15, 12:30 PM

Note: Network issues due to fire that damaged fibers between Portland and Seattle

Id: 1259 By: knuth

RS01SBPS
8/28/15, 8:00 PM 8/28/15, 8:30 PM

Note: Outage during major utility power failure in Seattle. Possible data gap < 24h.

Id: 1262 By: knuth

RS01SBPS
1/7/16, 1:10 AM 1/7/16, 1:52 AM

Note: Four 1-minute outages between Portland and Seattle due to maintenance. Possible data gap < 24h.

Id: 1266 By: knuth

RS01SBPS
3/10/16, 6:06 PM 3/11/16, 4:30 AM

Note: Fiber break between Portland and Seattle. Possible data gap < 24h.

Id: 1268 By: knuth

RS01SBPS
5/20/16, 12:33 PM 5/20/16, 2:04 PM

Note: Fiber break between Portland and Pacific City. Possible data gap < 24h.

Id: 1274 By: knuth

RS01SBPS
7/11/16, 10:53 PM 7/11/16, 11:51 PM

Note: Unexplained loss of power at Pittock Building in Portland. Possible data gap < 24h.

Id: 1276 By: knuth

RS01SBPS
12/17/16, 1:00 PM 12/17/16, 2:00 PM

Note: Corvalis data center lost power. Possible data gap < 24h.

Id: 1281 By: knuth

RS01SBPS
12/21/16, 8:50 PM 12/23/16, 7:44 AM

Note: Fiber break in Portland due to train crash. Possible data gap < 24h.

Id: 1282 By: knuth

RS01SBPS
1/8/17, 2:58 PM 1/8/17, 4:41 PM

Note: Network outage during major Seattle utility power failure. Possible data gap < 24h.

Id: 1283 By: knuth

RS01SBPS
1/9/17, 1:32 PM 1/9/17, 4:30 PM

Note: Lightning strike in Pacific City led to data interruption through isolation of both cable lines from shore station equipment. Possible data gap < 24h.

Id: 1286 By: knuth

RS01SBPS
2/7/17, 8:00 AM 2/7/17, 10:00 AM

Note: Outage during PNWGP 1-hour router-maintenance. Possible data gap < 24h.

Id: 1288 By: knuth

RS01SBPS
2/15/17, 9:43 AM 2/15/17, 12:16 PM

Note: On Wednesday, February 15, power to the North and South cable lines of the Cabled Array was interrupted and all deployed infrastructure went offline. Power was restored on February 16. No hardware issue subsea was identified. Possible data gap < 24h.

Id: 1289 By: knuth

RS01SBPS
1/18/18, 10:00 PM 1/19/18, 2:00 PM

A brief violent storm caused loss of power to both the North and South cable lines and the deployed infrastructure during this time. For more information please contact help@oceanobservatories.org. (Redmine # 13109)

Id: 319 By: friedrich.knuth
Flag: not_operational Exclude: No

RS01SBPS
8/22/18, 1:00 PM 8/24/18, 4:00 PM

On Wednesday Aug 22 2018, an automatic protective shutdown of primary power to the OOI Cabled Array occurred during installation of a new chiller system. Power was restored on Aug 24. Due to loss of power to the Cabled Array marine infrastructure, data were not collected by the instruments.

Id: 1486 By: lgarzio
Flag: not_operational Exclude: No

Review Notes

Metadata Start Date End Date Comment
RS01SBPS-PC01A-4B-PHSENA102

no pressure coordinate in NetCDF files

By Leila Belabbassi, on 6/20/19

RS01SBPS-PC01A-4B-PHSENA102

data files pressure data are incorrect

By Leila Belabbassi, on 6/20/19

RS01SBPS-PC01A-4B-PHSENA102
11/15/14, 12:00 AM 12/15/14, 12:00 AM

suspect dta

By Leila Belabbassi, on 6/20/19

RS01SBPS-PC01A-4B-PHSENA102
2/5/15, 12:00 AM 3/10/15, 12:00 AM

suspect data

By Leila Belabbassi, on 6/20/19

RS01SBPS-PC01A-4B-PHSENA102
12/20/15, 12:00 AM 7/15/16, 12:00 AM

suspect data

By Leila Belabbassi, on 6/20/19

New Note