Dep. | Preferred Method | Stream | DD | FD | SG | EG | Gaps | GD | TS | Rate (s) | Pressure Comp. | Time Order | Valid Data | Missing Data | Data Comp. | Missing Coords. | Review |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | streamed | phsen_data_record | 281 | 266 | 3 | 0 | 4 | 12 | 6,272 | 3,600 | 195 / | 1 | 1 | 2 | Complete | ||
2 | streamed | phsen_data_record | 377 | 365 | 1 | 0 | 4 | 11 | 8,570 | 3,600 | 195 / | 1 | 1 | 2 | Complete | ||
3 | streamed | phsen_data_record | 376 | 374 | 0 | 0 | 3 | 3 | 8,841 | 3,600 | 195 / | 1 | 1 | 2 | Complete | ||
4 | streamed | phsen_data_record | 325 | 321 | 0 | 0 | 3 | 4 | 7,565 | 3,599 | 195 / | 1 | 1 | 2 | Complete |
Deployment: | 1 | 2 | 3 | 4 |
---|---|---|---|---|
phsen_data_record | 95% | 97% | 99% | 99% |
Deployment: | 1 | 2 | 3 | 4 |
---|---|---|---|---|
1 | 0.00 | |||
2 | 0.08 | 0.00 | ||
3 | 0.08 | 0.00 | 0.00 | |
4 | 0.08 | 0.00 | 0.00 | 0.00 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
RS01SBPS |
12/7/14, 2:45 PM | 12/15/14, 7:00 PM |
Note: PFE down. HVPS1 MOV explosion, 800A breaker tripped, investigation and restoration Id: 1248 By: knuth |
RS01SBPS |
1/7/15, 2:32 AM | 1/7/15, 3:06 AM |
Note: PNWGP Portland <-> Seattle outage. Possible data gap < 24h. Id: 1250 By: knuth |
RS01SBPS |
1/30/15, 7:00 PM | 2/3/15, 7:00 PM |
Note: Intermittent partial data loss due to storage drive problems at OTB Id: 1251 By: knuth |
RS01SBPS |
3/21/15, 10:10 AM | 3/22/15, 12:20 AM |
Note: PNWGP outage due to City of Seattle fiber cable work. Possible data gap < 24h. Id: 1256 By: knuth |
RS01SBPS |
6/12/15, 8:00 PM | 6/15/15, 12:30 PM |
Note: Network issues due to fire that damaged fibers between Portland and Seattle Id: 1259 By: knuth |
RS01SBPS |
8/28/15, 8:00 PM | 8/28/15, 8:30 PM |
Note: Outage during major utility power failure in Seattle. Possible data gap < 24h. Id: 1262 By: knuth |
RS01SBPS |
1/7/16, 1:10 AM | 1/7/16, 1:52 AM |
Note: Four 1-minute outages between Portland and Seattle due to maintenance. Possible data gap < 24h. Id: 1266 By: knuth |
RS01SBPS |
3/10/16, 6:06 PM | 3/11/16, 4:30 AM |
Note: Fiber break between Portland and Seattle. Possible data gap < 24h. Id: 1268 By: knuth |
RS01SBPS |
5/20/16, 12:33 PM | 5/20/16, 2:04 PM |
Note: Fiber break between Portland and Pacific City. Possible data gap < 24h. Id: 1274 By: knuth |
RS01SBPS |
7/11/16, 10:53 PM | 7/11/16, 11:51 PM |
Note: Unexplained loss of power at Pittock Building in Portland. Possible data gap < 24h. Id: 1276 By: knuth |
RS01SBPS |
12/17/16, 1:00 PM | 12/17/16, 2:00 PM |
Note: Corvalis data center lost power. Possible data gap < 24h. Id: 1281 By: knuth |
RS01SBPS |
12/21/16, 8:50 PM | 12/23/16, 7:44 AM |
Note: Fiber break in Portland due to train crash. Possible data gap < 24h. Id: 1282 By: knuth |
RS01SBPS |
1/8/17, 2:58 PM | 1/8/17, 4:41 PM |
Note: Network outage during major Seattle utility power failure. Possible data gap < 24h. Id: 1283 By: knuth |
RS01SBPS |
1/9/17, 1:32 PM | 1/9/17, 4:30 PM |
Note: Lightning strike in Pacific City led to data interruption through isolation of both cable lines from shore station equipment. Possible data gap < 24h. Id: 1286 By: knuth |
RS01SBPS |
2/7/17, 8:00 AM | 2/7/17, 10:00 AM |
Note: Outage during PNWGP 1-hour router-maintenance. Possible data gap < 24h. Id: 1288 By: knuth |
RS01SBPS |
2/15/17, 9:43 AM | 2/15/17, 12:16 PM |
Note: On Wednesday, February 15, power to the North and South cable lines of the Cabled Array was interrupted and all deployed infrastructure went offline. Power was restored on February 16. No hardware issue subsea was identified. Possible data gap < 24h. Id: 1289 By: knuth |
RS01SBPS |
1/18/18, 10:00 PM | 1/19/18, 2:00 PM |
A brief violent storm caused loss of power to both the North and South cable lines and the deployed infrastructure during this time. For more information please contact help@oceanobservatories.org. (Redmine # 13109)
Id: 319
By: friedrich.knuth
|
RS01SBPS |
8/22/18, 1:00 PM | 8/24/18, 4:00 PM |
On Wednesday Aug 22 2018, an automatic protective shutdown of primary power to the OOI Cabled Array occurred during installation of a new chiller system. Power was restored on Aug 24. Due to loss of power to the Cabled Array marine infrastructure, data were not collected by the instruments.
Id: 1486
By: lgarzio
|
Metadata | Start Date | End Date | Comment |
---|---|---|---|
RS01SBPS-PC01A-4B-PHSENA102 |
no pressure coordinate in NetCDF files By Leila Belabbassi, on 6/20/19 |
||
RS01SBPS-PC01A-4B-PHSENA102 |
data files pressure data are incorrect By Leila Belabbassi, on 6/20/19 |
||
RS01SBPS-PC01A-4B-PHSENA102 |
11/15/14, 12:00 AM | 12/15/14, 12:00 AM |
suspect dta By Leila Belabbassi, on 6/20/19 |
RS01SBPS-PC01A-4B-PHSENA102 |
2/5/15, 12:00 AM | 3/10/15, 12:00 AM |
suspect data By Leila Belabbassi, on 6/20/19 |
RS01SBPS-PC01A-4B-PHSENA102 |
12/20/15, 12:00 AM | 7/15/16, 12:00 AM |
suspect data By Leila Belabbassi, on 6/20/19 |