Dep. | Preferred Method | Stream | DD | FD | SG | EG | Gaps | GD | TS | Rate (s) | Pressure Comp. | Time Order | Valid Data | Missing Data | Data Comp. | Missing Coords. | Review |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | streamed | do_stable_sample | / | Blocked | |||||||||||||
2 | streamed | do_stable_sample | / | Blocked | |||||||||||||
3 | streamed | do_stable_sample | / | Blocked | |||||||||||||
4 | streamed | do_stable_sample | / | Blocked |
All good!
Metadata | Start Date | End Date | Comment |
---|---|---|---|
RS01SLBS |
12/7/14, 2:45 PM | 12/15/14, 7:00 PM |
Note: PFE down. HVPS1 MOV explosion, 800A breaker tripped, investigation and restoration Id: 1183 By: knuth |
RS01SLBS |
1/7/15, 2:32 AM | 1/7/15, 3:06 AM |
Note: PNWGP Portland <-> Seattle outage Id: 1185 By: knuth |
RS01SLBS |
1/30/15, 7:00 PM | 2/3/15, 7:00 PM |
Note: Intermittent partial data loss due to storage drive problems at OTB Id: 1186 By: knuth |
RS01SLBS |
3/21/15, 10:10 AM | 3/22/15, 12:20 AM |
Note: PNWGP outage due to City of Seattle fiber cable work Id: 1189 By: knuth |
RS01SLBS |
6/12/15, 8:00 PM | 6/15/15, 12:30 PM |
Note: Network issues due to fire that damaged fibers between Portland and Seattle Id: 1190 By: knuth |
RS01SLBS |
8/28/15, 8:00 PM | 8/28/15, 8:30 PM |
Note: Outage during major utility power failure in Seattle Id: 1194 By: knuth |
RS01SLBS |
1/7/16, 1:10 AM | 1/7/16, 1:52 AM |
Note: Four 1-minute outages between Portland and Seattle due to maintenance Id: 1195 By: knuth |
RS01SLBS |
3/10/16, 6:06 PM | 3/11/16, 4:30 AM |
Note: Fiber break between Portland and Seattle Id: 1196 By: knuth |
RS01SLBS |
5/20/16, 12:33 PM | 5/20/16, 2:04 PM |
Note: Fiber break between Portland and Pacific City Id: 1197 By: knuth |
RS01SLBS |
7/11/16, 10:53 PM | 7/11/16, 11:51 PM |
Note: Unexplained loss of power at Pittock Building in Portland Id: 1198 By: knuth |
RS01SLBS |
12/17/16, 1:00 PM | 12/17/16, 2:00 PM |
Note: Corvalis data center lost power Id: 1201 By: knuth |
RS01SLBS |
12/21/16, 8:50 PM | 12/23/16, 7:44 AM |
Note: Fiber break in Portland due to train crash Id: 1202 By: knuth |
RS01SLBS |
1/8/17, 2:58 PM | 1/8/17, 4:41 PM |
Note: Network outage during major Seattle utility power failure Id: 1203 By: knuth |
RS01SLBS |
1/9/17, 1:32 PM | 1/9/17, 4:30 PM |
Note: Lightning strike in Pacific City led to data interruption through isolation of both cable lines from shore station equipment. Id: 1205 By: knuth |
RS01SLBS |
2/7/17, 8:00 AM | 2/7/17, 10:00 AM |
Note: Outage during PNWGP 1-hour router-maintenance Id: 1206 By: knuth |
RS01SLBS |
2/15/17, 9:43 AM | 2/15/17, 12:16 PM |
Note: On Wednesday, February 15, power to the North and South cable lines of the Cabled Array was interrupted and all deployed infrastructure went offline. Power was restored on February 16. No hardware issue subsea was identified. Id: 1207 By: knuth |
RS01SLBS |
1/18/18, 10:00 PM | 1/19/18, 2:00 PM |
A brief violent storm caused loss of power to both the North and South cable lines and the deployed infrastructure during this time. For more information please contact help@oceanobservatories.org. (Redmine # 13109)
Id: 327
By: friedrich.knuth
|
RS01SLBS |
8/22/18, 1:00 PM | 8/24/18, 4:00 PM |
On Wednesday Aug 22 2018, an automatic protective shutdown of primary power to the OOI Cabled Array occurred during installation of a new chiller system. Power was restored on Aug 24. Due to loss of power to the Cabled Array marine infrastructure, data were not collected by the instruments.
Id: 1487
By: lgarzio
|
Metadata | Start Date | End Date | Comment |
---|---|---|---|
RS01SLBS-LJ01A-12-DOSTAD101 |
There are no data available for download for deployments 1-4 because the data were delivered via the CTD data stream (Redmine 8662). Now that the DO instrument has been separated from the CTD, the old DO data should be ingested in the DO data stream. Users currently have to go to the collocated CTD reference designator to get the DO data prior to 2018-11-07. By Lori Garzio, on 8/29/19 |