Metadata | Start Date | End Date | Comment |
---|---|---|---|
RS03AXBS |
12/7/14, 2:45 PM | 12/15/14, 7:00 PM |
Note: PFE down. HVPS1 MOV explosion, 800A breaker tripped, investigation and restoration Id: 1212 By: knuth |
RS03AXBS |
1/7/15, 2:32 AM | 1/7/15, 3:06 AM |
Note: PNWGP Portland <-> Seattle outage Id: 1214 By: knuth |
RS03AXBS |
1/30/15, 7:00 PM | 2/3/15, 7:00 PM |
Note: Intermittent partial data loss due to storage drive problems at OTB Id: 1215 By: knuth |
RS03AXBS |
3/21/15, 10:10 AM | 3/22/15, 12:20 AM |
Note: PNWGP outage due to City of Seattle fiber cable work Id: 1218 By: knuth |
RS03AXBS |
6/12/15, 8:00 PM | 6/15/15, 12:30 PM |
Note: Network issues due to fire that damaged fibers between Portland and Seattle Id: 1220 By: knuth |
RS03AXBS |
8/28/15, 8:00 PM | 8/28/15, 8:30 PM |
Note: Outage during major utility power failure in Seattle Id: 1222 By: knuth |
RS03AXBS |
1/7/16, 1:10 AM | 1/7/16, 1:52 AM |
Note: Four 1-minute outages between Portland and Seattle due to maintenance Id: 1223 By: knuth |
RS03AXBS |
3/10/16, 6:06 PM | 3/11/16, 4:30 AM |
Note: Fiber break between Portland and Seattle Id: 1224 By: knuth |
RS03AXBS-LJ03A-10-ADCPTE303 Method: streamed Stream: adcp_velocity_beam |
3/27/16, 8:00 PM | 7/12/16, 8:00 PM |
Issues generating L1 data products due to problem with beam 4 data generation at instrument level. Redmine 10948
Id: 1225
By: knuth
|
RS03AXBS |
5/20/16, 12:33 PM | 5/20/16, 2:04 PM |
Note: Fiber break between Portland and Pacific City Id: 1226 By: knuth |
RS03AXBS-LJ03A-10-ADCPTE303 Method: streamed Stream: adcp_velocity_beam |
7/11/16, 8:00 PM | 7/30/17, 8:00 PM |
Possible electrical interference during Deployment 3 of this instrument caused an irregular data pattern in the adcp_velocity_beam-pressure parameter, making these data suspect. Pressure data from this deployment should not be used to calculate bin depths.
Id: 1912
By: m.vardaro
|
RS03AXBS |
7/11/16, 10:53 PM | 7/11/16, 11:51 PM |
Note: Unexplained loss of power at Pittock Building in Portland Id: 1228 By: knuth |
RS03AXBS |
12/17/16, 1:00 PM | 12/17/16, 2:00 PM |
Note: Corvalis data center lost power Id: 1229 By: knuth |
RS03AXBS |
12/21/16, 8:50 PM | 12/23/16, 7:44 AM |
Note: Fiber break in Portland due to train crash Id: 1230 By: knuth |
RS03AXBS |
1/8/17, 2:58 PM | 1/8/17, 4:41 PM |
Note: Network outage during major Seattle utility power failure Id: 1231 By: knuth |
RS03AXBS |
1/9/17, 1:32 PM | 1/9/17, 4:30 PM |
Note: Lightning strike in Pacific City led to data interruption through isolation of both cable lines from shore station equipment. Id: 1232 By: knuth |
RS03AXBS |
2/7/17, 8:00 AM | 2/7/17, 10:00 AM |
Note: Outage during PNWGP 1-hour router-maintenance Id: 1233 By: knuth |
RS03AXBS |
2/15/17, 9:43 AM | 2/15/17, 12:16 PM |
Note: On Wednesday, February 15, power to the North and South cable lines of the Cabled Array was interrupted and all deployed infrastructure went offline. Power was restored on February 16. No hardware issue subsea was identified. Id: 1235 By: knuth |
RS03AXBS |
1/18/18, 10:00 PM | 1/19/18, 2:00 PM |
A brief violent storm caused loss of power to both the North and South cable lines and the deployed infrastructure during this time. For more information please contact help@oceanobservatories.org. (Redmine # 13109)
Id: 326
By: friedrich.knuth
|
RS03AXBS |
8/22/18, 1:00 PM | 8/24/18, 4:00 PM |
On Wednesday Aug 22 2018, an automatic protective shutdown of primary power to the OOI Cabled Array occurred during installation of a new chiller system. Power was restored on Aug 24. Due to loss of power to the Cabled Array marine infrastructure, data were not collected by the instruments.
Id: 1491
By: lgarzio
|
Metadata | Start Date | End Date | Comment |
---|---|---|---|
RS03AXBS-LJ03A-10-ADCPTE303 |
The .nc files for deployments 1-3 are missing the coordinates pressure, lat and lon. By Lori Garzio, on 12/16/19 |
||
RS03AXBS-LJ03A-10-ADCPTE303 |
|||
RS03AXBS-LJ03A-10-ADCPTE303 |
40-70% of seawater velocities for deployments 1-3 are NaNs, outside of global ranges, or outliers (+/- 5 SD). By Lori Garzio, on 12/16/19 |
||
RS03AXBS-LJ03A-10-ADCPTE303 Deployment: 1 |
Missing data for deployment 1 should be annotated. By Lori Garzio, on 12/16/19 |