Data Concentrator Logger (DCL)

Reference Designator
CE07SHSM-MFD35-00-DCLENG000
Start Depth
87
End Depth
87
Location
Current Status
Engineering
Class
DCLEN (Data Concentrator Logger (DCL))
Series
DCLEN-G
Science Discipline
Make
WHOI
Model
Data Concentrator Logger
M2M Example
https://ooinet.oceanobservatories.org/api/m2m/12576/sensor/inv/CE07SHSM/MFD35/00-DCLENG000/metadata
Method Data Stream Content Type
recovered_host cg_dcl_eng_dcl_cpu_uptime_recovered CPU Uptime Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_dlog_aarm_recovered Accelerometer Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_dlog_mgr_recovered Data Log Manager Report M2M Engineering
recovered_host cg_dcl_eng_dcl_dlog_status_recovered Data Logger Status Report M2M Engineering
recovered_host cg_dcl_eng_dcl_error_recovered Error Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_gps_recovered GPS Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_msg_counts_recovered Message Counts Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_pps_recovered Pulse Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_status_recovered Status Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_superv_recovered Leak Detect Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_cpu_uptime CPU Uptime Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_dlog_aarm Accelerometer Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_dlog_mgr Data Log Manager Report M2M Engineering
telemetered cg_dcl_eng_dcl_dlog_status Data Logger Status Report M2M Engineering
telemetered cg_dcl_eng_dcl_error Error Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_gps GPS Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_msg_counts Message Counts Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_pps Pulse Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_status Status Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_superv Leak Detect Data Report M2M Engineering
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 Review OC1503D 04/05/2015 09/23/2015 CGMCE-07SHSM-00001 OL000415 46.9861 -124.566 87 87
2 Review OC1510A 10/13/2015 05/13/2016 CGMCE-07SHSM-00002 OL000427 46.9875 -124.569 87 87
3 Review TN-342 05/05/2016 09/27/2016 CGMCE-07SHSM-00003 CGCON-MDCL35-00001 46.9895 -124.569 87 87
4 Review AT37-03 09/20/2016 04/13/2017 CGMCE-07SHSM-00004 CGCON-MDCL35-00006 46.9859 -124.566 87 87
5 Review SKQ201704S 04/11/2017 10/06/2017 CGMCE-07SHSM-00005 CGCON-MDCL36-00001 46.9882 -124.567 89 89
6 Review SKQ201715S 10/03/2017 03/29/2018 CGMCE-07SHSM-00006 CGCON-MDCL36-00009 46.9852 -124.564 87 87
7 Review SKQ201808S 03/25/2018 09/20/2018 CGMCE-07SHSM-00007 CGCON-MDCL36-00014 46.9881 -124.568 87 87
8 Review SR1813 09/18/2018 04/26/2019 CGMCE-07SHSM-00008 CGCON-MDCL36-00001 46.9835 -124.564 87 87
9 Review SKQ201910S 04/24/2019 10/12/2019 CGMCE-07SHSM-00009 CGCON-MDCL36-00043 46.9878 -124.568 87 87
10 Review SKQ201921S 10/10/2019 CGMCE-07SHSM-00010 CGCON-MDCL36-00021 46.9841 -124.566 87 87

No notes yet.

New Note

Metadata Start Date End Date Comment
CE07SHSM-MFD35
8/11/16, 8:00 PM 9/26/16, 8:00 PM

The Power System Controller on CE07SHSM indicates the power connection to the MFN short-circuited on 2016-08-12 at 23:30 UTC. Failure is indicated by decreased voltage (70 VDC instead of 380 VDC) and increased current draw (1900 mA instead of 120 mA) to the CVT. This symptom is indicative of a short-circuit in the power lines of either the stretch hose (most likely) or EM Chain. In the past, this failure has been associated with a failed stretch hose. Have disabled all further power and communications with the MFN. This means no more telemetered data from: ADCPT2, VEL3D, CTDBP2 + DOSTA, PRESF, PCO2W, PHSEN2, OPTAA2, ZPLSC

Id: 908 By: michaesm

CE07SHSM
12/1/17, 9:35 AM 3/25/18, 3:09 PM

Data loss due to a power system failure. The mooring stopped receiving power from photo voltaic panel 1 of 4 on Nov-2. By Nov-20, the mooring stopped receiving power from two more solar panels (PV2 & PV4) and one of two wind turbines (WT2). This indicates the Power System Controller (PSC) they connect to is failing. Mooring components will be shut down as the mooring loses the ability to recharge its batteries.

Id: 1237 By: crisien
Flag: not_operational Exclude: No

CE07SHSM-MFD35
Method: telemetered
5/25/19, 8:40 AM 10/10/19, 5:07 PM

The high voltage power supply providing power to the seafloor dataloggers and instrumentation failed for reasons unknown at this time. No further telemetered data will be available for this deployment.

Id: 1690 By: wingardc
Flag: not_operational Exclude: No

CE07SHSM-MFD35
Method: recovered-host
5/25/19, 8:40 AM 10/10/19, 5:07 PM

The high voltage power supply providing power to the seafloor dataloggers and instrumentation failed for reasons unknown at this time. No further telemetered data will be available for this deployment.

Id: 1749 By: wingardc
Flag: not_operational Exclude: No

CE07SHSM-MFD35
Method: telemetered
11/20/19, 1:45 PM 12/4/19, 10:20 PM

Due to reduced power on the mooring (limited recharging of the batteries with light winds and low levels of sunlight), we have had to reduce the operating schedule of the seafloor platform. Normally we run the system hourly, but have reduced that schedule to every 3 hours.

Id: 1832 By: wingardc

CE07SHSM-MFD35
Method: telemetered
12/25/19, 11:45 PM

Power to the seafloor sensors failed. With the exception of the VEL3D and OPTAA, the sensors on the seafloor platform should continue to autonomously sample for the remainder of deployment. Until we recover and redeploy the mooring in the spring of 2020, no further telemetered data will be available from the seafloor sensors.

Id: 1869 By: wingardc
Flag: not_operational Exclude: No

CE07SHSM
Method: telemetered
5/13/20, 6:40 PM

Due to a bug in the mooring telemetry system, data during this time range was not telemetered to shore. It was recorded on the mooring and instruments and will be available in the recovered data streams.

Id: 2185 By: wingardc
Flag: not_available Exclude: No