Method | Data Stream | Content | Type | |
---|---|---|---|---|
recovered_host | pco2a_a_dcl_instrument_air_recovered | In-Air Data Products | Report M2M Stats | Science |
recovered_host | pco2a_a_dcl_instrument_water_recovered | In-Water Data Products | Report M2M Stats | Science |
telemetered | pco2a_a_dcl_instrument_air | In-Air Data Products | Report M2M Stats | Science |
telemetered | pco2a_a_dcl_instrument_water | In-Water Data Products | Report M2M Stats | Science |
Deployment | Cruise | Start Date | Stop Date | Mooring Asset | Node Asset | Sensor Asset | Latitude | Longitude | Deployment Depth | Water Depth |
---|---|---|---|---|---|---|---|---|---|---|
1 Review | AT-26-30 | 03/15/2015 | 11/26/2015 | CGMGA-01SUMO-00001 | CGINS-PCO2AA-34223 | -42.9228 | -42.4393 | 0 | 5161 | |
2 Review | NBP-15-10 | 11/14/2015 | 11/08/2016 | CGMGA-01SUMO-00002 | CGINS-PCO2AA-33154 | -42.9246 | -42.5867 | 0 | 5188 | |
3 Review | NBP16-09 | 10/27/2016 | 01/14/2018 | CGMGA-01SUMO-00003 | CGINS-PCO2AA-34231 | -42.9204 | -42.4409 | 0 | 5175 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
GA01SUMO-SBD12-04-PCO2AA000 |
pco2_co2flux is an array of fill values for every deployment. See CP01CNSM-SBD12-04-PCO2AA000 for additional notes on potentially the same issue. By Lori Garzio, on 8/1/19 |
||
GA01SUMO-SBD12-04-PCO2AA000 Deployment: 2 |
Data from '2016-09-14T18:47:55' to '2016-09-23T23:47:45' are available in the telemetered data stream but not the recovered_host data stream These data should be available in the recovered data stream. By Lori Garzio, on 8/1/19 |
||
GA01SUMO-SBD12-04-PCO2AA000 Deployment: 3 |
1/1/17, 12:00 AM | 1/14/18, 10:24 AM |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
GA01SUMO |
3/15/15, 5:25 PM | 11/26/15, 5:08 AM |
Deployment 1: Buoy log files showed that seawater was first detected inside the buoy well on 3/26/2015. Both leak detectors showed increasing presence of water over the period of deployment. Upon recovery of the mooring, no external damage was visible and the buoy did not appear to be floating lower than normal. Id: 653 By: lgarzio |
GA01SUMO-SBD12 |
3/15/15, 5:25 PM | 11/26/15, 5:08 AM |
Deployment 1: Upon recovery, the bottom of the buoy was heavily biofouled with gooseneck barnacles. The barnacle coverage likely caused imporper sea water flushing at the location of the intakes and sensor faces for the subsurface instruments. Id: 655 By: lgarzio |
GA01SUMO-SBD12-04-PCO2AA000 |
3/15/15, 5:25 PM | 11/26/15, 5:08 AM |
Deployment 1: Instrument failed 6 hours after deployment.
Id: 418
By: lgarzio
|
GA01SUMO-SBD12 |
11/14/15, 4:06 PM | 11/8/16, 5:10 AM |
Deployment 2: Upon recovery, the bottom of the buoy was heavily biofouled with barnacles. Id: 664 By: lgarzio |
GA01SUMO-SBD12 |
10/26/16, 9:47 PM | 1/14/18, 5:24 AM |
Deployment 3: Upon recovery, the bottom of the buoy was heavily biofouled. Id: 386 By: lgarzio |