Velocity Profiler (75 kHz)

Reference Designator
GA03FLMA-RIM01-02-ADCPSL003
Start Depth
500
End Depth
500
Location
ADCP Float
Current Status
Review Complete
Class
ADCPS (Velocity Profiler (long range))
Series
ADCPS-L
Science Discipline
Physical
Make
Teledyne RDI
Model
WorkHorse LongRanger Sentinel 75khz - inductive
M2M Example
https://ooinet.oceanobservatories.org/api/m2m/12576/sensor/inv/GA03FLMA/RIM01/02-ADCPSL003/metadata
Method Data Stream Content Type
recovered_host adcps_jln_sio_mule_instrument Data Products Report M2M Stats Science
recovered_inst adcp_config Configuration Data Report M2M Engineering
recovered_inst adcp_engineering Engineering Data Report M2M Engineering
recovered_inst adcp_velocity_earth Earth Coordinates Data Products Report M2M Stats Science
telemetered adcps_jln_sio_mule_instrument Data Products Report M2M Stats Science
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 Review AT-26-30 03/17/2015 11/22/2015 CGMGA-03FLMA-00001 CGINS-ADCPSL-20503 -42.493 -42.8707 502 5165
2 Review NBP-15-10 11/25/2015 11/05/2016 CGMGA-03FLMA-00002 CGINS-ADCPSL-23497 -42.4946 -42.9211 495 5142
3 Review NBP16-09 10/30/2016 01/09/2018 CGMGA-03FLMA-00003 CGINS-ADCPSL-18352 -42.4921 -42.8802 500 5166
Metadata Start Date End Date Comment
GA03FLMA-RIM01-02-ADCPSL003
Deployment: 2

Pressure change in June 2016 also captured by the CTDMOs on the mooring (annotation ID 661).

By Lori Garzio, on 8/21/19

GA03FLMA
Deployment: 2
1/15/16, 12:00 AM 2/20/16, 12:00 AM

In Jan - Feb 2016, the signal of a colder, fresher water mass appears to be captured by several CTDs on GA03FLMA and GA03FLMB. Salinity and density drop suddenly for several days. This appears to be a real event as the phenomenon is captured by multiple instruments located on two moorings, but should be further investigated. Density and salinity drop suddenly on the following CTDs:
GA03FLMA-RIM01-02-CTDMOG044
GA03FLMA-RIM01-02-CTDMOG045
GA03FLMA-RIM01-02-CTDMOG046
GA03FLMB-RIM01-02-CTDMOG065
GA03FLMB-RIM01-02-CTDMOG066

By Lori Garzio, on 1/11/19

New Note

Metadata Start Date End Date Comment
GA03FLMA-RIM01-02-ADCPSL003
Method: telemetered
Stream: adcps_jln_sio_mule_instrument
3/17/15, 3:45 PM

Telemetered inductive ADCP data is in pd12 format which does not include the depth-to-first-bin value which is needed for proper calculation of the data products. A nominal value is entered into the system so that telemetered data can be used when needed. For the best data the recovered data in pd0 format should be used.

Id: 1921 By: cdobson

GA03FLMA
11/25/15, 2:21 PM 1/9/18, 7:15 AM

Deployments 2 and 3: Data were not transmitted via satellite telemetry.

Id: 375 By: lgarzio

GA03FLMA
5/31/16, 8:00 PM 6/19/16, 8:00 PM

Deployment 2: Mooring was blown down by ~500m. Corresponds to the presence of eddies in the region based on altimetry imagery.

Id: 661 By: lgarzio

GA03FLMA-RIM01-02-ADCPSL003
10/30/16, 7:17 PM 1/9/18, 7:15 AM

Deployment 3: No data available for this deployment - data recovered on the controller contained mostly error messages, and the instrument was found flooded at recovery.

Id: 1501 By: lgarzio
Flag: not_operational Exclude: No