Velocity Profiler (75 kHz)

Reference Designator
GI01SUMO-RII11-02-ADCPSN010
Start Depth
500
End Depth
500
Location
Sensor cage
Current Status
Review Complete
Class
ADCPS (Velocity Profiler (long range))
Series
ADCPS-N
Science Discipline
Physical
Make
Teledyne RDI
Model
WorkHorse LongRanger Sentinel 75khz - inductive
M2M Example
https://ooinet.oceanobservatories.org/api/m2m/12576/sensor/inv/GI01SUMO/RII11/02-ADCPSN010/metadata
Method Data Stream Content Type
recovered_host adcps_jln_stc_instrument_recovered Data Products Report M2M Stats Science
recovered_host adcps_jln_stc_metadata_recovered Metadata Report M2M Engineering
recovered_inst adcp_config Configuration Data Report M2M Engineering
recovered_inst adcp_engineering Engineering Data Report M2M Engineering
recovered_inst adcp_velocity_earth Earth Coordinates Data Products Report M2M Stats Science
telemetered adcps_jln_stc_instrument Data Products Report M2M Stats Science
telemetered adcps_jln_stc_metadata Metadata Report M2M Engineering
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 Review KN-221-4 09/10/2014 08/22/2015 CGMGI-01SUMO-00001 CGINS-ADCPSN-21717 59.9337 -39.4738 500 2685
2 Review AT-30-01 08/15/2015 07/19/2016 CGMGI-01SUMO-00002 CGINS-ADCPSN-22865 59.9436 -39.5737 500 2668
3 Review AR-07-01 07/10/2016 08/14/2017 CGMGI-01SUMO-00003 CGINS-ADCPSN-21654 59.9341 -39.4673 500 2691
4 Review AR21 08/05/2017 10/12/2017 CGMGI-01SUMO-00004 CGINS-ADCPSN-23579 59.9449 -39.5751 500 2659
5 Review AR30-03 06/08/2018 08/09/2019 CGMGI-01SUMO-00005 CGINS-ADCPSN-21654 59.9329 -39.4655 500 2693
6 Review AR35-05 08/05/2019 CGMGI-01SUMO-00006 CGINS-ADCPSN-23579 59.9451 -39.574 500 2664
Metadata Start Date End Date Comment
GI01SUMO
Deployment: 4
10/12/17, 12:00 AM 6/14/18, 8:02 AM

The surface buoy detached from the mooring and the subsurface portion of the mooring fell to the seafloor (see annotation ID 102). Excluding all mooring data for this time range from final statistics.

By Lori Garzio, on 1/15/19

New Note

Metadata Start Date End Date Comment
GI01SUMO-RII11-02-ADCPSN010
Method: telemetered
Stream: adcps_jln_stc_instrument
9/10/14, 2:50 PM

Telemetered inductive ADCP data is in pd12 format which does not include the depth-to-first-bin value which is needed for proper calculation of the data products. A nominal value is entered into the system so that telemetered data can be used when needed. For the best data the recovered data in pd0 format should be used.

Id: 1931 By: cdobson

GI01SUMO
2/14/15, 7:00 PM 8/21/15, 8:00 PM

Deployment 1: Status data sent from the buoy included leak detects in the buoy well, drop in battery voltage, and loss of wind turbine input. Upon recovery, the buoy was primarily intact but several instruments were damaged and/or missing. Ice build-up on the tower is speculated to be the cause for much of the damage. No telemetered or recovered_host data expected. Functional instruments could continue to collect data using internal battery power and storage cards.

Id: 46 By: lgarzio

GI01SUMO
1/26/16, 7:00 PM 7/18/16, 8:00 PM

Deployment 2: A period of violent weather caused power outages on multiple instruments. No telemetered or recovered_host data expected. Functional instruments could continue to collect data using internal battery power and storage cards. Upon recovery, the buoy well was flooded.

Id: 47 By: lgarzio

GI01SUMO
12/26/16, 7:00 PM 4/6/17, 8:00 PM

Deployment 3: Wind turbines were disabled due to evidence of ice build-up on the surface buoy tower. The platform's battery charge state declined steadily. As of 2017-01-15, all DCLs were shut down and the telemetry schedule was reduced to conserve power. Battery-powered instruments should continue to collect data. UPDATE 2017-04-07: With increasing daylight at this location, sufficient power was generated by solar panels to re-establish limited high-bandwidth telemetry and data transmission. UPDATE: at recovery, wind turbines were missing their hubs and blades, and one solar panel was missing.

Id: 121 By: lgarzio

GI01SUMO
8/5/17, 2:17 PM 6/14/18, 4:02 AM

Deployment 4: at 10:03 UTC on 12 October 2017 the Irminger Sea Surface Mooring stopped all communications. At recovery, the surface buoy was missing. The subsurface portion of the mooring had fallen to the seafloor and was recovered. CTDMOs, CTDBP-F, DOSTA, and ADCP instrumentation were full ocean depth rated and survived, although any recovered data available after 2017-10-12T10:03:00 are suspect. All other instrumentation imploded or flooded. The cause for the loss of the buoy is inconclusive.

Id: 102 By: lgarzio

GI01SUMO
6/19/19, 8:00 PM

Deployment 5: Battery voltage dropped below 24V. All DCLs were turned off. CPM1 was placed on a wake schedule. Data collection and telemetry will be irregular until voltage rebounds.

Id: 1625 By: cdobson

GI01SUMO
Method: telemetered
10/21/19, 8:00 PM

Deployment 6: *UPDATED 2020-04-27: As of 2020-02-21 data for most instruments are being telemetered again (via Iridium). A gap in telemetered data is expected between 2019-10-22 and 2020-02-21 and will not be backfilled but these data will be available upon recovery.*Both fleet broadband units have failed and no more telemetered data is expected at this time. Instruments are believed to be operating as normal and their data will be available upon recovery.

Id: 1743 By: cdobson