Velocity Profiler (75 kHz)

Reference Designator
GI03FLMB-RIM01-02-ADCPSL007
Start Depth
500
End Depth
500
Location
ADCP Float
Current Status
Review Complete
Class
ADCPS (Velocity Profiler (long range))
Series
ADCPS-L
Science Discipline
Physical
Make
Teledyne RDI
Model
WorkHorse LongRanger Sentinel 75khz - inductive
M2M Example
https://ooinet.oceanobservatories.org/api/m2m/12576/sensor/inv/GI03FLMB/RIM01/02-ADCPSL007/metadata
Method Data Stream Content Type
recovered_host adcps_jln_sio_mule_instrument Data Products Report M2M Stats Science
recovered_inst adcp_config Configuration Data Report M2M Engineering
recovered_inst adcp_engineering Engineering Data Report M2M Engineering
recovered_inst adcp_velocity_earth Earth Coordinates Data Products Report M2M Stats Science
telemetered adcps_jln_sio_mule_instrument Data Products Report M2M Stats Science
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 Review KN-221-4 09/16/2014 08/20/2015 CGMGI-03FLMB-00001 CGINS-ADCPSL-18353 59.7127 -39.2302 502 2825
2 Review AT-30-01 08/21/2015 07/18/2016 CGMGI-03FLMB-00002 CGINS-ADCPSL-23381 59.7182 -39.3536 500 2812
3 Review AR-07-01 07/13/2016 08/11/2017 CGMGI-03FLMB-00003 CGINS-ADCPSL-21497 59.7155 -39.3148 500 2825
4 Review AR21 08/07/2017 06/11/2018 CGMGI-03FLMB-00004 CGINS-ADCPSL-21450 59.7166 -39.3521 500 2817
5 Review AR30-03 06/11/2018 08/10/2019 CGMGI-03FLMB-00005 CGINS-ADCPSL-18351 59.7143 -39.3133 500 2829
6 Review AR35-05 08/08/2019 CGMGI-03FLMB-00006 CGINS-ADCPSL-23381 59.7205 -39.3547 500 2819

No notes yet.

New Note

Metadata Start Date End Date Comment
GI03FLMB-RIM01-02-ADCPSL007
Method: telemetered
Stream: adcps_jln_sio_mule_instrument
9/16/14, 9:24 AM

Telemetered inductive ADCP data is in pd12 format which does not include the depth-to-first-bin value which is needed for proper calculation of the data products. A nominal value is entered into the system so that telemetered data can be used when needed. For the best data the recovered data in pd0 format should be used.

Id: 1924 By: cdobson

GI03FLMB
9/16/14, 9:24 AM 8/20/15, 8:56 AM

Deployment 1: Mooring was deployed 5-10m shallower than planned.

Id: 1451 By: lgarzio

GI03FLMB
8/21/15, 1:11 PM 7/17/16, 8:00 PM

Deployment 2: Mooring was deployed 5m deeper than planned.

Id: 1452 By: lgarzio

GI03FLMB-RIM01-02-ADCPSL007
7/26/16, 7:28 AM 8/11/17, 8:02 AM

Deployment 3: Instrument failed shortly after deployment due to the depletion of internal batteries.

Id: 697 By: lgarzio
Flag: not_operational Exclude: No

GI03FLMB
8/7/17, 11:49 AM 6/11/18, 3:36 PM

Deployment 4: Mooring was deployed 10-15m deeper than planned.

Id: 1453 By: lgarzio