Stream: flord_m_glider_instrument_recovered

Id
377
Display Name
Data Products
Description
Science Data Products
Stream Type
Science
Time Parameter
7
Binsize Minutes
720
Uses Ctd
No
Id Name Display Name Standard Name Unit Fill Value Precision Identifier Type Level
PD7 time Time, UTC time seconds since 1900-01-01 -9999999
PD10 port_timestamp Port Timestamp, UTC seconds since 1900-01-01 -9999999
PD11 driver_timestamp Driver Timestamp, UTC seconds since 1900-01-01 -9999999
PD12 internal_timestamp Internal Timestamp, UTC seconds since 1900-01-01 -9999999
PD16 preferred_timestamp Preferred Timestamp 1 empty
PD21 seawater_scattering_coefficient Total Scattering Coefficient of Pure Seawater m-1 -9999999 Science Data L2
PD25 optical_backscatter Optical Backscatter m-1 -9999999 FLUBSCT_L2 Science Data L2
PD863 ingestion_timestamp Ingestion Timestamp, UTC seconds since 1900-01-01 -9999
PD1401 m_present_secs_into_mission Elapsed Mission Time s
PD1402 m_present_time Time at the Start of the Cycle seconds since 1970-01-01
PD1494 sci_m_present_secs_into_mission Elapsed Mission Time Based on Science Derived Start Times s
PD1495 sci_m_present_time Science Derived Time at the Start of the CycleC seconds since 1970-01-01
PD1537 sci_flbb_bb_units Total Volume Scattering Coefficient m-1 sr-1 FLUBSCT_L1 Science Data L1
PD1538 sci_flbb_chlor_units Chlorophyll-a Concentration mass_concentration_of_chlorophyll_a_in_sea_water µg L-1 CHLAFLO_L1 Science Data L1
PD2751 sci_flbb_timestamp FLBB Timestamp seconds since 1970-01-01
PD2752 sci_flbb_bb_ref Optical Backscatter Reference 1
PD2753 sci_flbb_bb_sig Optical Backscatter Measurement 1 FLUBSCT_L0 Unprocessed Data L0
PD2754 sci_flbb_chlor_ref Sci Flbb Chlor Ref 1
PD2755 sci_flbb_chlor_sig Chlorophyll-a Measurement 1 CHLAFLO_L0 Unprocessed Data L0
PD2756 sci_flbb_therm Sci Flbb Therm 1
Reference Designator Name Location Start Depth End Depth
GA05MOAS-GL364-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GA05MOAS-GL470-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GA05MOAS-GL493-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GA05MOAS-GL494-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GA05MOAS-GL495-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GA05MOAS-GL496-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GA05MOAS-GL538-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL363-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL453-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL469-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL477-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL478-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL484-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL485-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL486-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL493-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL495-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GI05MOAS-GL559-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GP05MOAS-GL361-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GP05MOAS-GL362-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GP05MOAS-GL363-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GP05MOAS-GL364-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GP05MOAS-GL365-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GP05MOAS-GL453-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GP05MOAS-GL469-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GP05MOAS-GL523-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GP05MOAS-GL525-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GP05MOAS-GL537-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GS05MOAS-GL484-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GS05MOAS-GL485-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GS05MOAS-GL486-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GS05MOAS-GL524-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GS05MOAS-GL560-01-FLORDM000 2-Wavelength Fluorometer 0 1000
GS05MOAS-GL561-01-FLORDM000 2-Wavelength Fluorometer 0 1000