Asset: CGINS-FLORTD-01222

Type
Sensor
Mobile
0
Description of Equipment
3-Wavelength Fluorometer: FLORT Series D
Manufacturer
WET Labs
Model
ECO Triplet-w
Manufacturer Serial No
1222
Firmware Version
5.33
Acquisition Date
8/21/14
Original Cost
$13,013.52
Comments
Deployment Cruise Reference Designator Deployment Number Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
AT-27 CP03ISSM-RID27-02-FLORTD000 2 05/09/2015 10/21/2015 CGMCP-03ISSM-00002 CGINS-FLORTD-01222 40.3595 -70.8853 7 97
AR-04 CP04OSSM-RID27-02-FLORTD000 4 05/27/2016 10/12/2016 CGMCP-04OSSM-00004 CGINS-FLORTD-01222 39.94 -70.8774 7 446
AR21 GI01SUMO-SBD12-02-FLORTD000 4 08/05/2017 10/12/2017 CGMGI-01SUMO-00004 CGINS-FLORTD-01222 59.9449 -39.5751 1 2659

No notes yet.

Class Asset UID Start Date Serial Name Value Notes
FLORTD CGINS-FLORTD-01222 08/19/2014 1222 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01222 08/19/2014 1222 CC_dark_counts_cdom 44
FLORTD CGINS-FLORTD-01222 08/19/2014 1222 CC_dark_counts_chlorophyll_a 47
FLORTD CGINS-FLORTD-01222 08/19/2014 1222 CC_dark_counts_volume_scatter 64
FLORTD CGINS-FLORTD-01222 08/19/2014 1222 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01222 08/19/2014 1222 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01222 08/19/2014 1222 CC_scale_factor_cdom 0.0904
FLORTD CGINS-FLORTD-01222 08/19/2014 1222 CC_scale_factor_chlorophyll_a 0.0121
FLORTD CGINS-FLORTD-01222 08/19/2014 1222 CC_scale_factor_volume_scatter 1.953e-06
FLORTD CGINS-FLORTD-01222 08/19/2014 1222 CC_scattering_angle 124 Constant
FLORTD CGINS-FLORTD-01222 01/12/2016 1222 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01222 01/12/2016 1222 CC_dark_counts_cdom 43
FLORTD CGINS-FLORTD-01222 01/12/2016 1222 CC_dark_counts_chlorophyll_a 49
FLORTD CGINS-FLORTD-01222 01/12/2016 1222 CC_dark_counts_volume_scatter 66
FLORTD CGINS-FLORTD-01222 01/12/2016 1222 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01222 01/12/2016 1222 CC_measurement_wavelength 700
FLORTD CGINS-FLORTD-01222 01/12/2016 1222 CC_scale_factor_cdom 0.0797
FLORTD CGINS-FLORTD-01222 01/12/2016 1222 CC_scale_factor_chlorophyll_a 0.0119
FLORTD CGINS-FLORTD-01222 01/12/2016 1222 CC_scale_factor_volume_scatter 1.948E-06
FLORTD CGINS-FLORTD-01222 01/12/2016 1222 CC_scattering_angle 124
FLORTD CGINS-FLORTD-01222 01/05/2017 1222 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01222 01/05/2017 1222 CC_dark_counts_cdom 47
FLORTD CGINS-FLORTD-01222 01/05/2017 1222 CC_dark_counts_chlorophyll_a 49
FLORTD CGINS-FLORTD-01222 01/05/2017 1222 CC_dark_counts_volume_scatter 64
FLORTD CGINS-FLORTD-01222 01/05/2017 1222 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01222 01/05/2017 1222 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01222 01/05/2017 1222 CC_scale_factor_cdom 0.0792
FLORTD CGINS-FLORTD-01222 01/05/2017 1222 CC_scale_factor_chlorophyll_a 0.0119
FLORTD CGINS-FLORTD-01222 01/05/2017 1222 CC_scale_factor_volume_scatter 2.094E-06
FLORTD CGINS-FLORTD-01222 01/05/2017 1222 CC_scattering_angle 124 Constant