Asset: CGINS-FLORTD-01318

Type
Sensor
Mobile
0
Description of Equipment
3-Wavelength Fluorometer: FLORT Series D
Manufacturer
WET Labs
Model
ECO Triplet-w
Manufacturer Serial No
1318
Firmware Version
Acquisition Date
7/17/15
Original Cost
$13,403.46
Comments
Deployment Cruise Reference Designator Deployment Number Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
NBP-15-10 GA01SUMO-SBD12-02-FLORTD000 2 11/14/2015 11/08/2016 CGMGA-01SUMO-00002 CGINS-FLORTD-01318 -42.9246 -42.5867 1 5188
AR21 GI03FLMB-RIS01-05-FLORTD000 4 08/07/2017 06/11/2018 CGMGI-03FLMB-00004 CGINS-FLORTD-01318 59.7166 -39.3521 30 2817
AR-39 CP03ISSM-RID27-02-FLORTD000 11 09/26/2019 CGMCP-03ISSM-00011 CGINS-FLORTD-01318 40.3594 -70.8851 7 93

No notes yet.

Class Asset UID Start Date Serial Name Value Notes
FLORTD CGINS-FLORTD-01318 07/10/2015 1318 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01318 07/10/2015 1318 CC_dark_counts_cdom 45
FLORTD CGINS-FLORTD-01318 07/10/2015 1318 CC_dark_counts_chlorophyll_a 51
FLORTD CGINS-FLORTD-01318 07/10/2015 1318 CC_dark_counts_volume_scatter 51
FLORTD CGINS-FLORTD-01318 07/10/2015 1318 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01318 07/10/2015 1318 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01318 07/10/2015 1318 CC_scale_factor_cdom 0.0901
FLORTD CGINS-FLORTD-01318 07/10/2015 1318 CC_scale_factor_chlorophyll_a 0.0121
FLORTD CGINS-FLORTD-01318 07/10/2015 1318 CC_scale_factor_volume_scatter 1.861e-06
FLORTD CGINS-FLORTD-01318 07/10/2015 1318 CC_scattering_angle 124 Constant
FLORTD CGINS-FLORTD-01318 03/29/2017 1318 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01318 03/29/2017 1318 CC_dark_counts_cdom 46
FLORTD CGINS-FLORTD-01318 03/29/2017 1318 CC_dark_counts_chlorophyll_a 49
FLORTD CGINS-FLORTD-01318 03/29/2017 1318 CC_dark_counts_volume_scatter 50
FLORTD CGINS-FLORTD-01318 03/29/2017 1318 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01318 03/29/2017 1318 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01318 03/29/2017 1318 CC_scale_factor_cdom 0.0861
FLORTD CGINS-FLORTD-01318 03/29/2017 1318 CC_scale_factor_chlorophyll_a 0.012
FLORTD CGINS-FLORTD-01318 03/29/2017 1318 CC_scale_factor_volume_scatter 2.129E-06
FLORTD CGINS-FLORTD-01318 03/29/2017 1318 CC_scattering_angle 124 Constant
FLORTD CGINS-FLORTD-01318 09/28/2018 1318 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01318 09/28/2018 1318 CC_dark_counts_cdom 50
FLORTD CGINS-FLORTD-01318 09/28/2018 1318 CC_dark_counts_chlorophyll_a 55
FLORTD CGINS-FLORTD-01318 09/28/2018 1318 CC_dark_counts_volume_scatter 51
FLORTD CGINS-FLORTD-01318 09/28/2018 1318 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01318 09/28/2018 1318 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01318 09/28/2018 1318 CC_scale_factor_cdom 0.0807
FLORTD CGINS-FLORTD-01318 09/28/2018 1318 CC_scale_factor_chlorophyll_a 0.0117
FLORTD CGINS-FLORTD-01318 09/28/2018 1318 CC_scale_factor_volume_scatter 2.163E-06
FLORTD CGINS-FLORTD-01318 09/28/2018 1318 CC_scattering_angle 124 Constant