Dep. | Preferred Method | Stream | DD | FD | SG | EG | Gaps | GD | TS | Rate (s) | Pressure Comp. | Time Order | Valid Data | Missing Data | Data Comp. | Missing Coords. | Review |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | recovered_host | flort_sample | 174 | 174 | 0 | 0 | 0 | 0 | 2,461,437 | 1 | 7 / | Complete | |||||
2 | recovered_host | flort_sample | 223 | 223 | 0 | 0 | 0 | 0 | 3,169,994 | 1 | 7 / | Complete | |||||
3 | recovered_host | flort_sample | 135 | 135 | 0 | 0 | 1 | 1 | 1,874,826 | 1 | 7 / | Complete | |||||
4 | recovered_host | flort_sample | 209 | 209 | 0 | 0 | 0 | 0 | 2,950,737 | 1 | 7 / | Complete | |||||
5 | recovered_host | flort_sample | 179 | 14 | 0 | 153 | 3 | 13 | 133,141 | 1 | 7 / | Complete | |||||
6 | recovered_host | flort_sample | 177 | 166 | 1 | 0 | 2 | 11 | 2,483,807 | 1 | 7 / | 1 | Complete | ||||
7 | recovered_host | flort_sample | 176 | 147 | 0 | 0 | 3 | 32 | 835,441 | 1 | 7 / | Complete |
Deployment: | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|
flort_sample | 100% | 100% | 100% | 100% | 8% | 94% | 84% |
Deployment: | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|
1 | 0.00 | ||||||
2 | 0.33 | 0.00 | |||||
3 | 0.29 | 0.09 | 0.00 | ||||
4 | 0.11 | 0.44 | 0.40 | 0.00 | |||
5 | 0.28 | 0.09 | 0.01 | 0.39 | 0.00 | ||
6 | 0.11 | 0.44 | 0.40 | 0.00 | 0.39 | 0.00 | |
7 | 0.29 | 0.09 | 0.00 | 0.40 | 0.01 | 0.40 | 0.00 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CE02SHSM-RID27 Method: telemetered |
11/22/19, 3:45 PM | 1/7/20, 1:30 PM |
Due to reduced power on the mooring (limited recharging of the batteries with light winds and sea lions blocking the solar panels), we have had to reduce the operating schedule of the 7 meter platform. Normally we run the system continuously, but have reduced that schedule to hourly. Id: 1836 By: wingardc |
CE02SHSM-RID27 Method: telemetered |
1/13/20, 1:45 PM |
During a large storm event on 2020-01-11, power from the wind turbines was lost. This is the primary means of recharging the battery system on the mooring. With the loss of recharging power, we have had to implement a conservative power model. These systems and instruments have been disabled for the foreseeable future, and no further data will collected from them.
Id: 1903
By: wingardc
|
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CE02SHSM-RID27-02-FLORTD000 |
The variable pressure_depth (dbar) is an array of all fill values for every deployment. This should contain valid pressure data. By Lori Garzio, on 7/3/19 |
||
CE02SHSM-RID27-02-FLORTD000 Deployment: 2 |
3/1/16, 12:00 AM | 5/16/16, 9:09 PM | |
CE02SHSM-RID27-02-FLORTD000 Deployment: 5 |
The missing data for deployment 5 should be annotated. By Lori Garzio, on 3/26/19 |
||
CE02SHSM-RID27-02-FLORTD000 Deployment: 6 |
12/1/17, 12:00 AM | 4/4/18, 1:57 PM |
total_volume_scattering_coefficient data show a repetitive pattern of increasing to the upper detection limit of the instrument and dropping to zero. A similar issue has been seen on CE06ISSM-RID16-02-FLORTD000 (see annotation ID 97). chl-a and CDOM data are also suspect. This dataset should be annotated. By Lori Garzio, on 7/3/19 |
CE02SHSM-RID27-02-FLORTD000 Deployment: 7 |