Velocity Profiler (300kHz)

Reference Designator
CE04OSSM-RID26-01-ADCPTC000
Review Status
Review Complete
Note
Depth
7m
Class
ADCPT (Velocity Profiler (short range))
Make / Model
Teledyne RDI / WorkHorse Sentinel 300khz

Dataset Reviews Last processed: 8/14/19, 7:26 PM

QC Check Info
Dep. Preferred Method Stream DD FD SG EG Gaps GD TS Rate (s) Pressure Comp. Time Order Valid Data Missing Data Data Comp. Missing Coords. Review
1 recovered_inst adcp_velocity_earth 399 399 0 0 0 0 38,176 900 7 / 1 Complete
2 recovered_inst adcp_velocity_earth 139 139 0 0 0 0 13,290 900 7 / 1 Complete
3 recovered_inst adcp_velocity_earth 203 203 0 0 0 0 19,448 900 7 / 1 Complete
4 recovered_inst adcp_velocity_earth 176 176 0 0 0 0 16,859 900 7 / 1 Complete
5 recovered_inst adcp_velocity_earth 175 175 0 0 0 0 16,690 900 7 / 1 Complete
6 recovered_host adcp_velocity_earth 178 167 0 11 0 0 12,763 899 7 / Complete
Data Ranges Review Images

Test Notes

  1. no comparison: timestamps do not match

Data Coverage

Deployment: 123456
adcp_velocity_earth 100%100%100%100%100%94%

Lat/Lon Differences (km)

Deployment: 123456
1 0.00
2 0.260.00
3 1.822.090.00
4 0.340.182.100.00
5 1.721.970.481.940.00
6 0.400.282.100.101.920.00

System Annotations

Metadata Start Date End Date Comment
CE04OSSM-RID26
Method: telemetered
6/15/19, 6:35 AM 6/17/19, 3:25 PM

The datalogger computer crashed and had to be power cycled to restore operation. Telemetered data was lost for this time period.

Id: 1684 By: wingardc
Flag: not_operational Exclude: No

CE04OSSM-RID26-01-ADCPTC000
Method: telemetered
8/29/19, 11:30 PM 10/21/19, 5:56 PM

Instrument started to intermittently produce binary data packets (expecting ASCIIHEX). Problem worsened over the course of a few days until the sensor failed entirely. No further data will be telemetered for the remainder of this deployment.

Id: 1739 By: wingardc
Flag: fail Exclude: No

CE04OSSM
Method: telemetered
5/6/20, 10:40 PM 5/11/20, 8:00 PM

Due to a bug in the mooring telemetry system, data during this time range was not telemetered to shore. It was recorded on the mooring and instruments and will be available in the recovered data streams.

Id: 2181 By: wingardc
Flag: not_available Exclude: No

Review Notes

Metadata Start Date End Date Comment
CE04OSSM-RID26-01-ADCPTC000

The pressure variable (daPa) is an array of fill values for every deployment.

By Lori Garzio, on 8/20/19

New Note