Dep. | Preferred Method | Stream | DD | FD | SG | EG | Gaps | GD | TS | Rate (s) | Pressure Comp. | Time Order | Valid Data | Missing Data | Data Comp. | Missing Coords. | Review |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | recovered_host | 162 | 148 | 0 | 0 | 0 | 0 | 1,453,174 | 7 / | 1 | 2 | 3 | Complete | ||||
2 | recovered_host | 214 | 214 | 0 | 0 | 0 | 0 | 2,116,506 | 7 / | 1 | 2 | 3 | Complete | ||||
3 | recovered_host | 146 | 146 | 0 | 0 | 0 | 0 | 2,275,521 | 7 / | 1 | 2 | 3 | Complete | ||||
4 | recovered_host | 206 | 96 | 0 | 110 | 0 | 0 | 1,483,891 | 7 / | 1 | 2 | 3 | Complete | ||||
5 | recovered_host | 179 | 48 | 0 | 129 | 1 | 2 | 722,294 | 7 / | 1 | 2 | 3 | Complete | ||||
6 | recovered_host | 178 | 31 | 0 | 146 | 1 | 1 | 200,595 | 7 / | 2 | 3 | Complete | |||||
7 | recovered_host | 180 | 171 | 0 | 0 | 1 | 1 | 1,618,195 | 7 / | 1 | 2 | 3 | Complete |
Deployment: | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|
91% | 100% | 100% | 47% | 27% | 17% | 95% |
Deployment: | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|
1 | 0.00 | ||||||
2 | 0.28 | 0.00 | |||||
3 | 0.44 | 0.22 | 0.00 | ||||
4 | 0.02 | 0.29 | 0.46 | 0.00 | |||
5 | 0.25 | 0.17 | 0.21 | 0.27 | 0.00 | ||
6 | 0.18 | 0.46 | 0.61 | 0.17 | 0.40 | 0.00 | |
7 | 0.27 | 0.10 | 0.17 | 0.29 | 0.08 | 0.44 | 0.00 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CE07SHSM-RID27-01-OPTAAD000 |
4/5/15, 1:15 PM |
Per vendor feedback, the first 1-2 min of each OPTAA instrument sampling period should be considered suspect. Signal drift can occur as the instrument warms up, flushes with seawater, and the filter wheel spins up. Users are encouraged to delete the first minute of data, at a minimum, from each measurement burst and then calculate a median average of the remaining data from the burst before working further with the OPTAA data. Id: 2098 By: wingardc |
|
CE07SHSM |
12/1/17, 9:35 AM | 3/25/18, 3:09 PM |
Data loss due to a power system failure. The mooring stopped receiving power from photo voltaic panel 1 of 4 on Nov-2. By Nov-20, the mooring stopped receiving power from two more solar panels (PV2 & PV4) and one of two wind turbines (WT2). This indicates the Power System Controller (PSC) they connect to is failing. Mooring components will be shut down as the mooring loses the ability to recharge its batteries.
Id: 1237
By: crisien
|
CE07SHSM-RID27-01-OPTAAD000 |
10/10/19, 5:30 PM |
The OPTAA burst duration was changed from 2 minutes to 4 minutes beginning 2019-10-10T21:30:00 UTC. Id: 1873 By: wingardc |
|
CE07SHSM-RID27-01-OPTAAD000 Method: telemetered |
12/7/19, 1:30 PM |
The external temperature sensor has started to show increasing variability during the measurement burst that does not correspond to the data from other, co-located in-situ temperature sensors.
Id: 2051
By: wingardc
|
|
CE07SHSM-RID27-01-OPTAAD000 Method: telemetered |
3/30/20, 10:35 AM |
Due to a change in the program telemetry systems, data from this sensor will not be telemetered to shore. The data is still being collected and will be available upon mooring recovery.
Id: 2067
By: wingardc
|
|
CE07SHSM Method: telemetered |
5/13/20, 6:40 PM |
Due to a bug in the mooring telemetry system, data during this time range was not telemetered to shore. It was recorded on the mooring and instruments and will be available in the recovered data streams.
Id: 2185
By: wingardc
|
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CE07SHSM-RID27-01-OPTAAD000 |
According to Roesler and Barnard (Optical proxy for phytoplankton biomass in the absence of photophysiology: Rethinking the absorption line height, Methods in Oceanography, 2013), “absorption meters are highly prone to biofouling, particularly biofilms which not only attenuate the collimated beam but also impact the scattering properties of the optical surfaces and tubes. In productive coastal waters biofouling can have significant impacts (i.e. 10% of the signal) within one to two weeks”. By Lori Garzio, on 6/28/19 |
||
CE07SHSM-RID27-01-OPTAAD000 |
There is no pressure variable in the .nc files. This should be a coordinate. By Lori Garzio, on 6/28/19 |
||
CE07SHSM-RID27-01-OPTAAD000 Deployment: 4 |
wavelength_a and wavelength_c are arrays of fill values for this deployment. These variables should contain the measurement wavelengths. By Lori Garzio, on 6/28/19 |