Dissolved Oxygen

Reference Designator
CE09OSSM-MFD37-03-DOSTAD000
Review Status
Review Complete
Note
Depth
540m
Class
DOSTA (Dissolved Oxygen Stable Response)
Make / Model
Aanderaa / Optode 4831

Dataset Reviews Last processed: 3/27/19, 7:40 PM

QC Check Info
Dep. Preferred Method Stream DD FD SG EG Gaps GD TS Rate (s) Pressure Comp. Time Order Valid Data Missing Data Data Comp. Missing Coords. Review
1 recovered_inst 170 170 0 0 0 0 16,226 900 542 / 550 1 Complete
2 recovered_inst / Complete
3 recovered_inst 134 134 0 0 0 0 12,760 900 542 / 539 2 2 Complete
4 recovered_inst 206 161 0 45 0 0 14,783 900 542 / 549 1 Complete
5 recovered_inst 178 178 0 0 0 0 17,085 900 542 / 538 1 Complete
6 recovered_inst 178 177 0 0 0 0 16,971 900 542 / 550 1 Complete
7 recovered_host 178 32 0 145 0 0 758 554 / 553 Complete
Data Ranges Review Images

Test Notes

  1. no comparison: timestamps do not match
  2. no other streams for comparison

Data Coverage

Deployment: 1234567
18%
100%100%78%100%99%

Lat/Lon Differences (km)

Deployment: 1234567
1 0.00
3 0.230.00
4 1.120.900.00
5 0.130.181.020.00
6 2.101.870.971.990.00
7 0.100.241.100.082.070.00

Example Composite Data Plot

System Annotations

Metadata Start Date End Date Comment
CE09OSSM-MFD37-03-DOSTAD000
4/9/15, 1:30 PM 3/25/18, 9:39 PM

Prior to the use of UV lamps for biofouling mitigation, this sensor would routinely biofoul after the first 6-8 weeks of a deployment (more common during a spring/summer deployment). Users should carefully examine the data to determine if biofouling has begun to dominate the signal.

Id: 2109 By: wingardc
Flag: suspect Exclude: No

CE09OSSM-MFD37
1/21/17, 7:00 PM 4/14/17, 8:00 PM

The high voltage lines providing power to the MFN via the CVT for CE09OSSM-00004 shorted out on 2017-01-22 at 08:31 UTC. Sea state was high, but not unusual for this time of year. Disabled future power scheduling to the MFN and applied an override to disable the CVT. No further data will be logged from the instruments on the MFN. This affects:
On DCL35:
* ADCPS (had already failed upon deployment)
* PCO2W -- should continue to autosample
* PHSEN -- should continue to autosample
* PRESF -- should continue to autosample
* VEL3D -- should continue to autosample
On DCL37
* CTDBP (plus DOSTA) -- should continue to autosample
* OPTAA
* ZPLSC -- had stopped reporting data early on in deployment, may still be autosampling

Id: 930 By: michaesm
Flag: not_available Exclude: No

CE09OSSM-MFD37-03-DOSTAD000
3/25/18, 9:39 PM

The use of UV lamps has been implemented for biofouling mitigation on this instrument as of 2018-03-26T01:39:00Z.

Id: 2119 By: wingardc

CE09OSSM-MFD37
Method: telemetered
6/26/19, 8:40 PM

The high voltage power supply providing power to the seafloor dataloggers and instrumentation failed for reasons unknown at this time. No further telemetered data will be available for this deployment.

Id: 1696 By: wingardc
Flag: not_operational Exclude: No

CE09OSSM-MFD37
Method: telemetered
11/3/19, 3:45 AM

Power to the seafloor sensors failed. With the exception of the VEL3D and OPTAA, the sensors on the seafloor platform should continue to autonomously sample for the remainder of deployment. Until we recover and redeploy the mooring in the spring of 2020, no further telemetered data will be available from the seafloor sensors.

Id: 1763 By: wingardc
Flag: not_operational Exclude: No

CE09OSSM
Method: telemetered
5/9/20, 8:40 PM 5/10/20, 8:00 PM

Due to a bug in the mooring telemetry system, data during this time range was not telemetered to shore. It was recorded on the mooring and instruments and will be available in the recovered data streams.

Id: 2182 By: wingardc
Flag: not_available Exclude: No

Review Notes

Metadata Start Date End Date Comment
CE09OSSM-MFD37-03-DOSTAD000
Deployment: 2

There are no data from any delivery method available for deployment 2. This should be annotated in the system (according to the ingest csv, the instrument failed at deployment).

By Lori Garzio, on 4/1/19

CE09OSSM-MFD37-03-DOSTAD000
Deployment: 7

Deployment 7 recovered_inst data should be available for download (the raw data file is available according to the ingest csv) or annotated to indicate why recovered_inst data are not available.

By Lori Garzio, on 4/1/19