Profiler Controller

Reference Designator
CP02PMUI-WFP01-00-WFPENG000
Review Status
Engineering
Note
Depth
15 to 70m
Class
WFPEN (Profiler Controller)
Make / Model
McLane / MMP

Dataset Reviews

No reviews found.

System Annotations

Metadata Start Date End Date Comment
CP02PMUI-WFP01
Method: telemetered
12/9/13, 7:00 PM 4/11/14, 6:37 PM

No telemetered data available because the surface buoy went adrift .

Id: 723 By: leila

CP02PMUI-WFP01
Method: telemetered
7/21/14, 6:36 AM 7/31/14, 12:30 AM

MMP failed. No telemetered data are available. The list of files got too long for the inductive modem and time run out to search and send out the data files via telemetry.

Id: 724 By: leila

CP02PMUI-WFP01
Method: telemetered
10/20/14, 6:36 AM 12/13/14, 7:00 PM

No telemetered data available because surface buoy broke free.

Id: 725 By: leila
Flag: not_available Exclude: No

CP02PMUI-WFP01
4/3/16, 9:35 AM 5/21/16, 8:00 AM

Wire Following Profiler profiling erratically and sometimes unable to reach the programmed top depth.

Id: 606 By: leila

CP02PMUI
4/3/16, 9:35 AM 5/21/16, 8:00 AM

No telemetered data available because surface buoy broke free.

Id: 116 By: leila

CP02PMUI-WFP01
2/13/17, 1:08 AM 6/7/17, 8:08 AM

Wire Following Profiler profiling erratically and sometimes unable to reach the programmed top depth.

Id: 607 By: leila

CP02PMUI
2/13/17, 1:08 AM 6/7/17, 8:08 AM

No telemetered data available because the surface buoy went adrift after a series of strong winter storms.

Id: 236 By: leila

CP02PMUI
3/3/18, 1:00 AM 4/11/18, 5:49 PM

Deployment 10: Surface buoy went adrift following a large storm on 02 March 2018.

Id: 1365 By: leila
Flag: not_operational Exclude: No

CP02PMUI-WFP01
3/23/19, 8:00 PM 4/18/19, 8:00 PM

Deployment 12: Erratic profiles 2019-03-24 through 2019-03-26 and 2019-04-03 onward until recovery.

Id: 1624 By: cdobson

CP02PMUI-WFP01
11/30/19, 7:00 PM 6/13/20, 12:02 PM

Deployment 14: Starting 11/29/2019 WFP01 was unable to complete full range descending profiles.

Id: 1829 By: cdobson

CP02PMUI-WFP01
12/31/19, 7:00 PM 6/13/20, 12:02 PM

Deployment 14: Due to a clock rollover issue, all WFPs have ceased sampling on 1/1/2020. No WFP data are being collected after this date. A resolution is being researched by the vendor.

Id: 1883 By: cdobson

Review Notes

No notes yet.

New Note