Dep. | Preferred Method | Stream | DD | FD | SG | EG | Gaps | GD | TS | Rate (s) | Pressure Comp. | Time Order | Valid Data | Missing Data | Data Comp. | Missing Coords. | Review |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | recovered_inst | adcp_velocity_earth | 17 | 16 | 0 | 0 | 0 | 0 | 731 | 1,800 | 94 / 91 | 1 | Complete | ||||
2 | recovered_inst | adcp_velocity_earth | 166 | 166 | 0 | 0 | 0 | 0 | 15,912 | 900 | 97 / 94 | 1 | Complete | ||||
3 | recovered_inst | adcp_velocity_earth | 207 | 207 | 0 | 0 | 0 | 0 | 9,880 | 1,800 | 96 / 89 | 1 | Complete | ||||
4 | recovered_inst | adcp_velocity_earth | 141 | 33 | 103 | 5 | 0 | 0 | 1,508 | 1,800 | 95 / 0 | 1 | Complete | ||||
5 | recovered_inst | adcp_velocity_earth | 248 | 248 | 0 | 0 | 0 | 0 | 11,860 | 1,800 | 92 / 92 | 1 | Complete | ||||
6 | recovered_inst | adcp_velocity_earth | 140 | 140 | 0 | 0 | 0 | 0 | 6,673 | 1,800 | 93 / 91 | 1 | Complete | ||||
7 | recovered_inst | adcp_velocity_earth | 148 | 148 | 0 | 0 | 0 | 0 | 7,065 | 1,800 | 93 / 93 | 1 | Complete |
Deployment: | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|
adcp_velocity_earth | 94% | 100% | 100% | 23% | 100% | 100% | 100% |
Deployment: | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|
1 | 0.00 | ||||||
2 | 0.64 | 0.00 | |||||
3 | 0.88 | 0.63 | 0.00 | ||||
4 | 0.62 | 0.03 | 0.65 | 0.00 | |||
5 | 0.04 | 0.65 | 0.91 | 0.63 | 0.00 | ||
6 | 0.60 | 0.90 | 0.64 | 0.89 | 0.64 | 0.00 | |
7 | 0.69 | 0.06 | 0.68 | 0.07 | 0.69 | 0.96 | 0.00 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CP03ISSM-MFD35-01-ADCPTF000 Method: telemetered |
12/14/14, 1:52 PM | 4/6/19, 2:51 PM |
Deployment 1-9; telemetered ADCP data for CP03ISSM Deployments 1 through 9 were in pd8 format which does not contain all of the necessary parameters to process the data. This data has been excluded from the system. Please use the recovered instrument data which is in pd0 format. Id: 1826 By: swhite |
CP03ISSM-MFD35 |
12/14/14, 1:52 PM | 12/29/14, 7:00 PM |
Telemetered and recovered host data are unavailabe because of ground faults on the sealoor Multi-Function Node. All communications to the instruments were shut down. Id: 315 By: leila |
CP03ISSM-MFD35-01-ADCPTF000 |
10/21/15, 1:44 PM | 5/14/16, 9:45 AM |
The instrument timestamps are off by 4 hours.
Id: 609
By: leila
|
CP03ISSM-MFD35-01-ADCPTF000 Stream: adcp_velocity_earth |
10/21/15, 1:44 PM |
ADCP data may contain acoustic interference from the ZPLSC instrument subject to real-time clock drift of either instrument. Id: 2002 By: swhite |
|
CP03ISSM-MFD35-01-ADCPTF000 Method: recovered |
10/21/15, 1:44 PM | 5/14/16, 9:45 AM |
Deployment 3: The ADCP instrument clock was set incorrectly at the time of deployment. Recovered instrument data have been processed to remove replace erroneous dates/times and replace with correct UTC dates/times. Id: 2046 By: swhite |
CP03ISSM-MFD35-01-ADCPTF000 |
6/14/16, 5:00 AM | 9/12/16, 4:00 AM |
No valid telemetered data. Id: 608 By: leila |
CP03ISSM-MFD35 |
2/3/17, 1:05 AM | 3/29/17, 10:00 PM |
All seafloor Multi-Function Node (MFD35 and MFD37) instruments have ceased data telemetry because the seafloor multi-function node had a high voltage ground fault and has been shut down to protect the instruments. Instrument on battery power will continue to collect data. Id: 332 By: leila |
CP03ISSM-MFD35 |
12/20/17, 4:00 AM | 3/28/18, 12:56 PM |
Deployment 7: Multi-Function Node failed.
Id: 334
By: leila
|
CP03ISSM-MFD35 Method: telemetered |
6/12/18, 7:05 AM | 10/26/18, 3:52 PM |
Data telemetry disabled due to chronic issues with power generation and management. The instruments could be revived to send data via telemetry when sufficient power is available. Note: Instruments may continue to collect data on internal battery power. Id: 1511 By: leila |
CP03ISSM-MFD35 Method: telemetered |
6/12/18, 7:05 AM | 10/28/18, 11:43 PM |
Data telemetry disabled due to chronic issues with power generation and management. The instruments could be revived to send data via telemetry when sufficient power is available. Note: Instruments may continue to collect data on internal battery power. Id: 1512 By: leila |
CP03ISSM-MFD35-01-ADCPTF000 Stream: adcp_velocity_earth |
9/26/19, 9:50 AM |
Deployment 11: ADCP instrument exhibits excessive clock drift. Telemetered data unavailable after 2019-12-19. Id: 2001 By: swhite |
|
CP03ISSM-MFD35 |
12/26/19, 7:00 PM |
Deployment 11: *UPDATED 2020-06-22: As of 2020-05-05 the ISSM MFN is back online in a reduced power usage mode. All MFN instruments will be powered on and sample 4 times a day (as opposed to 6 times a day). Data from this instruments will be telemetered home with the exception of the OPTAA which will only be availabe upon recovery. *UPDATED 2020-04-27: The MFN has been offline since 2019-01-03 and no telemetered data are expected from MFN instruments for the remainder of the deployment.*MFN offline due to power shortage after WT2 failure from 12/27/2019 to 12/30/2019 and again from 1/3/2019 to 1/6/2019. Instruments with external batteries will continue to log data internally. Id: 1877 By: cdobson |
|
CP03ISSM |
1/7/20, 7:00 PM |
Deployment 11: UPDATED 2020-04-27: As of 2020-03-12 telemetered data for most instruments are being sent home via Iridium. A gap in telemetered data is expected between 2020-01-08 and 2020-03-12 and will not be backfilled but these data will be available upon recovery.* As of 2020-01-08 both fleet broadband telemetry pathways have failed and data can no longer be telemetered to shore from this mooring. Instruments will continue to log data which will be available upon recovery.
Id: 1889
By: cdobson
|
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CP03ISSM-MFD35-01-ADCPTF000 |
The variable 'temperature' has units of cdeg_C but the global ranges in the system for this instrument are from -2 to 40. These global ranges. should be reviewed. By Lori Garzio, on 8/21/19 |
||
CP03ISSM-MFD35-01-ADCPTF000 Deployment: 3 |
The instrument timestamp and DCL controller timestamp are off by 4 hours in the raw data file. See Redmine ticket 11539 By Lori Garzio, on 8/21/19 |
||
CP03ISSM-MFD35-01-ADCPTF000 Deployment: 4 |
bin_depths are negative for this deployment - this should be investigated and fixed By Lori Garzio, on 8/21/19 |