Spectral Irradiance

Reference Designator
CP04OSSM-RID26-08-SPKIRB000
Review Status
Review Complete
Note
Depth
7m
Class
SPKIR (Spectral Irradiance)
Make / Model
Satlantic / OCR507 ICSW

Dataset Reviews Last processed: 7/9/19, 8:11 PM

QC Check Info
Dep. Preferred Method Stream DD FD SG EG Gaps GD TS Rate (s) Pressure Comp. Time Order Valid Data Missing Data Data Comp. Missing Coords. Review
1 recovered_host 150 149 0 0 0 0 1,879,140 1 7 / 1 2 Complete
2 recovered_host 168 167 0 0 0 0 2,386,873 1 7 / 1 2 Complete
3 recovered_host 205 185 0 0 3 20 2,611,174 1 7 / 1 2 Complete
4 recovered_host 139 139 0 0 0 0 2,277,499 1 7 / 1 2 Complete
5 recovered_host 240 240 0 0 0 0 3,141,960 1 7 / 1 2 Complete
6 recovered_host 150 91 0 42 1 16 1,452,799 1 7 / 1 2 Complete
7 recovered_host 153 153 0 0 0 0 2,479,166 1 7 / 1 2 Complete
Data Ranges Review Images

Test Notes

  1. no comparison: timestamps do not match
  2. missing: ['pressure']

Data Coverage

Deployment: 1234567
99%99%90%100%100%61%100%

Lat/Lon Differences (km)

Deployment: 1234567
1 0.00
2 0.510.00
3 0.560.790.00
4 0.490.120.850.00
5 0.580.820.030.880.00
6 0.460.200.880.080.910.00
7 0.540.750.050.810.080.840.00

Example Composite Data Plot

System Annotations

Metadata Start Date End Date Comment
CP04OSSM
Method: telemetered
10/22/15, 3:38 PM 5/13/16, 1:18 PM

Fuel cell impacted available instrument power, so telemetered data are not available or reliable. Recovered data are available for instruments that could record internally.

Id: 1362 By: leila

CP04OSSM
Method: telemetered
1/30/19, 10:00 AM 4/8/19, 7:39 AM

CP04OSSM D00009 buoy broke free and went adrift on 1/30/2019, 1500UTC. All instruments on the MFN ceased telemetry on 1/30/2019 and instruments on the buoy/NSIF continued to sample through 2/1/2019. No more telemetered data expected for this deployment.

Id: 1557 By: cdobson

CP04OSSM-RID26
9/29/19, 10:46 AM

Deployment 11: Delivery of telemetered data from instruments on DCL26 could potentially be delayed up to 24 hours.

Id: 1733 By: cdobson

CP04OSSM-RID26-08-SPKIRB000
9/29/19, 10:46 AM

The use of UV lamps has been implemented for bio-fouling mitigation on this instrument as of the start date/time of this annotation.

Id: 1775 By: swhite

Review Notes

Metadata Start Date End Date Comment
CP04OSSM-RID26-08-SPKIRB000

There is no pressure variable in the .nc files. This should be a coordinate.

By Lori Garzio, on 7/12/19

CP04OSSM-RID26-08-SPKIRB000

A substantial percentage (between 19-38%) of data are outside of global ranges for every deployment. Zooming in on the x-axis in the plots shows that all of the values that are outside of global ranges are negative.

By Lori Garzio, on 7/12/19

CP04OSSM-RID26-08-SPKIRB000
Deployment: 6

Missing data for this deployment should be annotated.

By Lori Garzio, on 7/12/19

New Note