Data Concentrator Logger (DCL)

Reference Designator
CE09OSSM-MFD35-00-DCLENG000
Start Depth
540
End Depth
540
Location
Current Status
Engineering
Class
DCLEN (Data Concentrator Logger (DCL))
Series
DCLEN-G
Science Discipline
Make
WHOI
Model
Data Concentrator Logger
M2M Example
https://ooinet.oceanobservatories.org/api/m2m/12576/sensor/inv/CE09OSSM/MFD35/00-DCLENG000/metadata
Method Data Stream Content Type
recovered_host cg_dcl_eng_dcl_cpu_uptime_recovered CPU Uptime Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_dlog_aarm_recovered Accelerometer Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_dlog_mgr_recovered Data Log Manager Report M2M Engineering
recovered_host cg_dcl_eng_dcl_dlog_status_recovered Data Logger Status Report M2M Engineering
recovered_host cg_dcl_eng_dcl_error_recovered Error Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_gps_recovered GPS Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_msg_counts_recovered Message Counts Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_pps_recovered Pulse Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_status_recovered Status Data Report M2M Engineering
recovered_host cg_dcl_eng_dcl_superv_recovered Leak Detect Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_cpu_uptime CPU Uptime Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_dlog_aarm Accelerometer Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_dlog_mgr Data Log Manager Report M2M Engineering
telemetered cg_dcl_eng_dcl_dlog_status Data Logger Status Report M2M Engineering
telemetered cg_dcl_eng_dcl_error Error Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_gps GPS Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_msg_counts Message Counts Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_pps Pulse Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_status Status Data Report M2M Engineering
telemetered cg_dcl_eng_dcl_superv Leak Detect Data Report M2M Engineering
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 Review OC1503D 04/09/2015 09/25/2015 CGMCE-09OSSM-00001 OL000455 46.8539 -124.958 542 542
2 Review OC1510A 10/15/2015 05/07/2016 CGMCE-09OSSM-00002 OL000467 46.8531 -124.954 542 542
4 Review AT37-03 09/20/2016 04/14/2017 CGMCE-09OSSM-00004 CGCON-MDCL35-00011 46.8508 -124.972 542 542
5 Review SKQ201704S 04/12/2017 10/06/2017 CGMCE-09OSSM-00005 CGCON-MDCL36-00010 46.8529 -124.959 542 542
6 Review SKQ201715S 10/04/2017 03/30/2018 CGMCE-09OSSM-00006 CGCON-MDCL36-00021 46.8478 -124.984 542 542
7 Review SKQ201808S 03/26/2018 09/19/2018 CGMCE-09OSSM-00007 CGCON-MDCL36-00025 46.853 -124.958 554 554
8 Review SR1813 09/19/2018 04/25/2019 CGMCE-09OSSM-00008 CGCON-MDCL36-00020 46.849 -124.978 542 542
9 Review SKQ201910S 04/24/2019 10/13/2019 CGMCE-09OSSM-00009 CGCON-MDCL36-00025 46.8527 -124.954 542 542
10 Review SKQ201921S 10/11/2019 CGMCE-09OSSM-00010 CGCON-MDCL36-00010 46.865 -124.948 542 542

No notes yet.

New Note

Metadata Start Date End Date Comment
CE09OSSM-MFD35
1/21/17, 7:00 PM 4/14/17, 8:00 PM

The high voltage lines providing power to the MFN via the CVT for CE09OSSM-00004 shorted out on 2017-01-22 at 08:31 UTC. Sea state was high, but not unusual for this time of year. Disabled future power scheduling to the MFN and applied an override to disable the CVT. No further data will be logged from the instruments on the MFN. This affects:
On DCL35:
* ADCPS (had already failed upon deployment)
* PCO2W -- should continue to autosample
* PHSEN -- should continue to autosample
* PRESF -- should continue to autosample
* VEL3D -- should continue to autosample
On DCL37
* CTDBP (plus DOSTA) -- should continue to autosample
* OPTAA
* ZPLSC -- had stopped reporting data early on in deployment, may still be autosampling

Id: 927 By: michaesm
Flag: not_available Exclude: No

CE09OSSM-MFD35
Method: telemetered
6/26/19, 8:40 PM 10/11/19, 6:59 PM

The high voltage power supply providing power to the seafloor dataloggers and instrumentation failed for reasons unknown at this time. No further telemetered data will be available for this deployment.

Id: 1695 By: wingardc
Flag: not_operational Exclude: No

CE09OSSM-MFD35
Method: recovered-host
6/26/19, 8:40 PM 10/11/19, 6:59 PM

The high voltage power supply providing power to the seafloor dataloggers and instrumentation failed for reasons unknown at this time. No further telemetered data will be available for this deployment.

Id: 1754 By: wingardc
Flag: not_operational Exclude: No

CE09OSSM-MFD35
Method: telemetered
11/3/19, 3:45 AM

Power to the seafloor sensors failed. With the exception of the VEL3D and OPTAA, the sensors on the seafloor platform should continue to autonomously sample for the remainder of deployment. Until we recover and redeploy the mooring in the spring of 2020, no further telemetered data will be available from the seafloor sensors.

Id: 1762 By: wingardc
Flag: not_operational Exclude: No

CE09OSSM
Method: telemetered
5/9/20, 8:40 PM 5/10/20, 8:00 PM

Due to a bug in the mooring telemetry system, data during this time range was not telemetered to shore. It was recorded on the mooring and instruments and will be available in the recovered data streams.

Id: 2182 By: wingardc
Flag: not_available Exclude: No