CTD

Reference Designator
CE09OSSM-MFD37-03-CTDBPE000
Start Depth
540
End Depth
540
Location
Multi-Function Node
Current Status
Review Complete
Class
CTDBP (CTD Pumped)
Series
CTDBP-E
Science Discipline
Physical
Make
Sea-Bird
Model
SBE 16plusV2
M2M Example
https://ooinet.oceanobservatories.org/api/m2m/12576/sensor/inv/CE09OSSM/MFD37/03-CTDBPE000/metadata
Method Data Stream Content Type
recovered_host ctdbp_cdef_dcl_instrument_recovered Data Products Report M2M Stats Science
recovered_inst ctdbp_cdef_instrument_recovered Data Products Report M2M Stats Science
telemetered ctdbp_cdef_dcl_instrument Data Products Report M2M Stats Science
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 Review OC1503D 04/09/2015 09/25/2015 CGMCE-09OSSM-00001 CGINS-CTDBPE-50005 46.8539 -124.958 542 542
2 Review OC1510A 10/15/2015 05/07/2016 CGMCE-09OSSM-00002 CGINS-CTDBPE-50068 46.8531 -124.954 542 542
3 Review TN-342 05/12/2016 09/22/2016 CGMCE-09OSSM-00003 CGINS-CTDBPE-50005 46.8537 -124.961 542 542
4 Review AT37-03 09/20/2016 04/14/2017 CGMCE-09OSSM-00004 CGINS-CTDBPE-50149 46.8508 -124.972 542 542
5 Review SKQ201704S 04/12/2017 10/06/2017 CGMCE-09OSSM-00005 CGINS-CTDBPE-50068 46.8529 -124.959 542 542
6 Review SKQ201715S 10/04/2017 03/30/2018 CGMCE-09OSSM-00006 CGINS-CTDBPE-50005 46.8478 -124.984 542 542
7 Review SKQ201808S 03/26/2018 09/19/2018 CGMCE-09OSSM-00007 CGINS-CTDBPE-50149 46.853 -124.958 554 554
8 Review SR1813 09/19/2018 04/25/2019 CGMCE-09OSSM-00008 CGINS-CTDBPE-50068 46.849 -124.978 542 542
9 Review SKQ201910S 04/24/2019 10/13/2019 CGMCE-09OSSM-00009 CGINS-CTDBPE-50005 46.8527 -124.954 542 542
10 Review SKQ201921S 10/11/2019 CGMCE-09OSSM-00010 CGINS-CTDBPE-50149 46.865 -124.948 542 542
Metadata Start Date End Date Comment
CE09OSSM-MFD37-03-CTDBPE000
Deployment: 1
8/28/15, 12:00 AM 9/25/15, 5:45 PM

Pressure shifted from around 550 dbar to 549 dbar. This instrument is on the seafloor so the sudden shift in pressure requires investigation and an annotation

By Lori Garzio, on 3/28/19

CE09OSSM-MFD37-03-CTDBPE000
Deployment: 2

There are no data from any delivery method available for deployment 2. This should be annotated in the system (according to the ingest csv, the instrument failed at deployment).

By Lori Garzio, on 3/27/19

CE09OSSM-MFD37-03-CTDBPE000
Deployment: 4
9/21/16, 1:26 AM 10/17/16, 12:00 AM

According to asset management, this instrument was deployed at 542 m. The pressure at the beginning of the deployment is around 560 dbar, then jumps up to around 547 dbar (closer to the planned deployment depth). This requires investigation and an annotation - excluding the data from the beginning of the deployment from summary data ranges.

By Lori Garzio, on 3/28/19

CE09OSSM-MFD37-03-CTDBPE000
Deployment: 7

Deployment 7 recovered_inst data should be available for download (the raw data file is available according to the ingest csv) or annotated to indicate why recovered_inst data are not available. The recovered_inst data will hopefully fill in the missing data at the end of the deployment (seen in the recovered_host data)

By Lori Garzio, on 3/27/19

New Note

Metadata Start Date End Date Comment
CE09OSSM-MFD37
1/21/17, 7:00 PM 4/14/17, 8:00 PM

The high voltage lines providing power to the MFN via the CVT for CE09OSSM-00004 shorted out on 2017-01-22 at 08:31 UTC. Sea state was high, but not unusual for this time of year. Disabled future power scheduling to the MFN and applied an override to disable the CVT. No further data will be logged from the instruments on the MFN. This affects:
On DCL35:
* ADCPS (had already failed upon deployment)
* PCO2W -- should continue to autosample
* PHSEN -- should continue to autosample
* PRESF -- should continue to autosample
* VEL3D -- should continue to autosample
On DCL37
* CTDBP (plus DOSTA) -- should continue to autosample
* OPTAA
* ZPLSC -- had stopped reporting data early on in deployment, may still be autosampling

Id: 930 By: michaesm
Flag: not_available Exclude: No

CE09OSSM-MFD37
Method: telemetered
6/26/19, 8:40 PM

The high voltage power supply providing power to the seafloor dataloggers and instrumentation failed for reasons unknown at this time. No further telemetered data will be available for this deployment.

Id: 1696 By: wingardc
Flag: not_operational Exclude: No

CE09OSSM-MFD37
Method: telemetered
11/3/19, 3:45 AM

Power to the seafloor sensors failed. With the exception of the VEL3D and OPTAA, the sensors on the seafloor platform should continue to autonomously sample for the remainder of deployment. Until we recover and redeploy the mooring in the spring of 2020, no further telemetered data will be available from the seafloor sensors.

Id: 1763 By: wingardc
Flag: not_operational Exclude: No

CE09OSSM
Method: telemetered
5/9/20, 8:40 PM 5/10/20, 8:00 PM

Due to a bug in the mooring telemetry system, data during this time range was not telemetered to shore. It was recorded on the mooring and instruments and will be available in the recovered data streams.

Id: 2182 By: wingardc
Flag: not_available Exclude: No