Velocity Profiler (75 kHz)

Reference Designator
GA01SUMO-RII11-02-ADCPSN010
Start Depth
500
End Depth
500
Location
Sensor cage
Current Status
Review Complete
Class
ADCPS (Velocity Profiler (long range))
Series
ADCPS-N
Science Discipline
Physical
Make
Teledyne RDI
Model
WorkHorse LongRanger Sentinel 75khz - inductive
M2M Example
https://ooinet.oceanobservatories.org/api/m2m/12576/sensor/inv/GA01SUMO/RII11/02-ADCPSN010/metadata
Method Data Stream Content Type
recovered_host adcps_jln_stc_instrument_recovered Data Products Report M2M Stats Science
recovered_host adcps_jln_stc_metadata_recovered Metadata Report M2M Engineering
recovered_inst adcp_config Configuration Data Report M2M Engineering
recovered_inst adcp_engineering Engineering Data Report M2M Engineering
recovered_inst adcp_velocity_earth Earth Coordinates Data Products Report M2M Stats Science
telemetered adcps_jln_stc_instrument Data Products Report M2M Stats Science
telemetered adcps_jln_stc_metadata Metadata Report M2M Engineering
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 Review AT-26-30 03/15/2015 11/26/2015 CGMGA-01SUMO-00001 CGINS-ADCPSN-21639 -42.9228 -42.4393 500 5161
2 Review NBP-15-10 11/14/2015 11/08/2016 CGMGA-01SUMO-00002 CGINS-ADCPSN-21638 -42.9246 -42.5867 500 5188
3 Review NBP16-09 10/27/2016 01/14/2018 CGMGA-01SUMO-00003 CGINS-ADCPSN-21639 -42.9204 -42.4409 500 5175
Metadata Start Date End Date Comment
GA01SUMO-RII11
12/4/15, 12:00 AM 3/14/16, 12:00 AM

Deployment 2: The recovered_host data from the following instruments have the same 4 data gaps [['2015-12-04', '2015-12-14'], ['2016-01-06', '2016-01-11'], ['2016-02-05', '2016-02-10'], ['2016-03-11', '2016-03-14']]. These gaps should be annotated to explain why the data are missing, or gaps should be filled in if the data are available. [02-FLORDG031, 02-FLORDG032, 02-FLORDG033, 02-DOSTAD031, 02-DOSTAD032, 02-DOSTAD033]

By Lori Garzio, on 2/11/19

GA01SUMO-RII11-02-ADCPSN010
Deployment: 3

There are no recovered_inst adcp_velocity_earth data available for download for this deployment. According to the ingest csv, raw recovered_inst data files are available but there may have been a parser issue. This should be investigated.

By Lori Garzio, on 8/21/19

GA01SUMO-RII11-02-ADCPSN010
Deployment: 3

The recovered_host .nc files for this deployment don't have pressure as a coordinate. (recovered_inst data are not available for this deployment). These files are also missing two key variables: percent_bad_beams and bin_depths

By Lori Garzio, on 8/21/19

New Note

Metadata Start Date End Date Comment
GA01SUMO-RII11-02-ADCPSN010
Method: telemetered
Stream: adcps_jln_stc_instrument
3/15/15, 5:25 PM

Telemetered inductive ADCP data is in pd12 format which does not include the depth-to-first-bin value which is needed for proper calculation of the data products. A nominal value is entered into the system so that telemetered data can be used when needed. For the best data the recovered data in pd0 format should be used.

Id: 1920 By: cdobson

GA01SUMO
3/15/15, 5:25 PM 11/26/15, 5:08 AM

Deployment 1: Buoy log files showed that seawater was first detected inside the buoy well on 3/26/2015. Both leak detectors showed increasing presence of water over the period of deployment. Upon recovery of the mooring, no external damage was visible and the buoy did not appear to be floating lower than normal.

Id: 653 By: lgarzio