Oregon Offshore Cabled Shallow Profiler Mooring

Reference Designator
CE04OSPS
Array Name
Coastal Endurance
Description
Profiler Moorings are a type of mooring that contain instruments fixed to profilers that move up and down the water column. Profilers either track along the mooring riser (wire-following profilers), or are tethered to a mooring-mounted winch that pays out line allowing the profiler to move through the water (shallow profilers). Instruments may also be attached to the mooring riser or affixed to an underwater platform on these moorings.
Latitude
44.374
Longitude
-124.956
Min Depth
20
Max Depth
588
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 TN-313 08/30/2014 08/02/2015 ATAPL-69839-002-0102 44.3741 -124.957
2 TN-326 08/03/2015 07/18/2016 ATAPL-69839-002-0105 44.3741 -124.956
3 SKQ201610S 07/19/2016 07/28/2017 ATAPL-69839-002-0105 44.3741 -124.956
4 RR1713 07/29/2017 07/17/2018 ATAPL-69839-002-0105 44.3741 -124.956
5 RR1811 07/17/2018 06/13/2019 ATAPL-69839-002-0102 44.3741 -124.956
6 AT-42-12 06/14/2019 ATAPL-69839-002-0102 44.3741 -124.956

No notes yet.

New Note

Metadata Start Date End Date Comment
CE04OSPS
12/7/14, 2:45 PM 12/15/14, 7:00 PM

Note: PFE down. HVPS1 MOV explosion, 800A breaker tripped, investigation and restoration

Id: 1033 By: knuth

CE04OSPS
1/7/15, 2:32 AM 1/7/15, 3:06 AM

Note: PNWGP Portland <-> Seattle outage

Id: 1034 By: knuth

CE04OSPS
1/30/15, 7:00 PM 2/3/15, 7:00 PM

Note: Intermittent partial data loss due to storage drive problems at OTB

Id: 1035 By: knuth

CE04OSPS
3/21/15, 10:10 AM 3/22/15, 12:20 AM

Note: Intermittent data gaps. PNWGP outage due to City of Seattle fiber cable work

Id: 1037 By: knuth

CE04OSPS
6/12/15, 8:00 PM 6/15/15, 12:30 PM

Note: Intermittent data gaps. Network issues due to fire that damaged fibers between Portland and Seattle

Id: 1038 By: knuth

CE04OSPS
8/28/15, 8:00 PM 8/28/15, 8:30 PM

Note: Intermittent data gaps. Outage during major utility power failure in Seattle

Id: 1042 By: knuth

CE04OSPS
1/7/16, 1:10 AM 1/7/16, 1:52 AM

Note: Four 1-minute outages between Portland and Seattle due to maintenance

Id: 1043 By: knuth

CE04OSPS
3/10/16, 6:06 PM 3/11/16, 4:30 AM

Note: Fiber break between Portland and Seattle

Id: 1044 By: knuth

CE04OSPS
5/20/16, 12:33 PM 5/20/16, 2:04 PM

Note: Fiber break between Portland and Pacific City

Id: 1047 By: knuth

CE04OSPS
7/11/16, 10:53 PM 7/11/16, 11:51 PM

Note: Unexplained loss of power at Pittock Building in Portland

Id: 1048 By: knuth

CE04OSPS
12/17/16, 1:00 PM 12/17/16, 2:00 PM

Note: Corvalis data center lost power

Id: 1050 By: knuth

CE04OSPS
12/21/16, 8:50 PM 12/23/16, 7:44 AM

Note: Fiber break in Portland due to train crash

Id: 1051 By: knuth

CE04OSPS
1/8/17, 2:58 PM 1/8/17, 4:41 PM

Note: Network outage during major Seattle utility power failure

Id: 1052 By: knuth

CE04OSPS
1/9/17, 1:30 PM 1/9/17, 3:25 PM

Note: Lightning strike in Pacific City led to isolation of both cable lines from shore station equipment, when Power Feed Equipment High Voltage Opening Switches operated. All deployed infrastructure went offline.

Id: 1053 By: knuth

CE04OSPS
2/7/17, 8:00 AM 2/7/17, 10:00 AM

Note: Intermittent data gaps. Outage during PNWGP 1-hour router-maintenance

Id: 1057 By: knuth

CE04OSPS
2/15/17, 9:43 AM 2/15/17, 12:16 PM

Note: Power Feed Equipment failure during major utility power issues related to lightning strike on Pacific City electrical sub-station. All deployed infrastructure went offline. Power was restored on February 16. No hardware issue subsea was identified.

Id: 1058 By: knuth

CE04OSPS
9/16/17, 7:30 AM 9/16/17, 8:13 AM

Data are suspect during this time range, due to the following event: On Saturday, September 16, 2017 at around 12:15 GMT, the CA Shallow Profiler at Endurance (CE04OSPS) went offline due to an overcurrent power event. Initial investigation indicated external aggression on one of the two anchor legs, pulling the platform that is normally fixed at 200m below the surface to 400m, and then rose to 100m before communications were lost. No data products are expected from CE04OSPS until the platform is re-deployed. For more information, please contact help@oceanobservatories.org

Id: 181 By: friedrich.knuth
Flag: suspect Exclude: No

CE04OSPS
Method: streamed
9/16/17, 8:13 AM 7/17/18, 11:00 AM

On Saturday, September 16, 2017 at around 12:15 GMT, the CA Shallow Profiler at Endurance (CE04OSPS) went offline due to an overcurrent power event. Initial investigation indicated external aggression on one of the two anchor legs, pulling the platform that is normally fixed at 200m below the surface to 400m, and then rose to 100m before communications were lost. No data products are expected from CE04OSPS until the platform is re-deployed. For more information, please contact help@oceanobservatories.org

Id: 221 By: friedrich.knuth
Flag: not_operational Exclude: No

CE04OSPS
8/22/18, 1:00 PM 8/24/18, 4:00 PM

On Wednesday Aug 22 2018, an automatic protective shutdown of primary power to the OOI Cabled Array occurred during installation of a new chiller system. Power was restored on Aug 24. Due to loss of power to the Cabled Array marine infrastructure, data were not collected by the instruments.

Id: 1485 By: lgarzio
Flag: not_operational Exclude: No