Asset: CGINS-FLORTD-01107

Type
Sensor
Mobile
0
Description of Equipment
3-Wavelength Fluorometer: FLORT Series D
Manufacturer
WET Labs
Model
ECO Triplet-w
Manufacturer Serial No
1107
Firmware Version
Acquisition Date
9/17/13
Original Cost
$12,634.25
Comments
Deployment Cruise Reference Designator Deployment Number Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
KN-221-4 GI03FLMB-RIS01-05-FLORTD000 1 09/16/2014 08/20/2015 CGMGI-03FLMB-00001 CGINS-FLORTD-01107 59.7127 -39.2302 30 2825
RB-16-05 GP03FLMB-RIS01-05-FLORTD000 4 07/04/2016 07/17/2017 CGMGP-03FLMB-00004 CGINS-FLORTD-01107 50.3293 -144.398 4146
DY096 GS01SUMO-SBD12-02-FLORTD000 4 12/04/2018 01/20/2020 CGMGS-01SUMO-00004 CGINS-FLORTD-01107 -54.4072 -89.206 1 4589

No notes yet.

Class Asset UID Start Date Serial Name Value Notes
FLORTD CGINS-FLORTD-01107 09/09/2013 1107 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01107 09/09/2013 1107 CC_dark_counts_cdom 47
FLORTD CGINS-FLORTD-01107 09/09/2013 1107 CC_dark_counts_chlorophyll_a 59
FLORTD CGINS-FLORTD-01107 09/09/2013 1107 CC_dark_counts_volume_scatter 52 Requires TEMPWAT and PRACSAL (PD2927/2929) from a nearby CTD
FLORTD CGINS-FLORTD-01107 09/09/2013 1107 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01107 09/09/2013 1107 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01107 09/09/2013 1107 CC_scale_factor_cdom 0.0903
FLORTD CGINS-FLORTD-01107 09/09/2013 1107 CC_scale_factor_chlorophyll_a 0.0122
FLORTD CGINS-FLORTD-01107 09/09/2013 1107 CC_scale_factor_volume_scatter 1.695e-06 Depth
FLORTD CGINS-FLORTD-01107 09/09/2013 1107 CC_scattering_angle 124 Constant
FLORTD CGINS-FLORTD-01107 02/04/2016 1107 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01107 02/04/2016 1107 CC_dark_counts_cdom 45
FLORTD CGINS-FLORTD-01107 02/04/2016 1107 CC_dark_counts_chlorophyll_a 52
FLORTD CGINS-FLORTD-01107 02/04/2016 1107 CC_dark_counts_volume_scatter 48 Requires TEMPWAT and PRACSAL (PD2927/2929) from a nearby CTD
FLORTD CGINS-FLORTD-01107 02/04/2016 1107 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01107 02/04/2016 1107 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01107 02/04/2016 1107 CC_scale_factor_cdom 0.0775
FLORTD CGINS-FLORTD-01107 02/04/2016 1107 CC_scale_factor_chlorophyll_a 0.0113
FLORTD CGINS-FLORTD-01107 02/04/2016 1107 CC_scale_factor_volume_scatter 1.654e-06 Depth
FLORTD CGINS-FLORTD-01107 02/04/2016 1107 CC_scattering_angle 124 Constant
FLORTD CGINS-FLORTD-01107 10/11/2017 1107 CC_angular_resolution 1.076 Constant
FLORTD CGINS-FLORTD-01107 10/11/2017 1107 CC_dark_counts_cdom 44
FLORTD CGINS-FLORTD-01107 10/11/2017 1107 CC_dark_counts_chlorophyll_a 52
FLORTD CGINS-FLORTD-01107 10/11/2017 1107 CC_dark_counts_volume_scatter 48
FLORTD CGINS-FLORTD-01107 10/11/2017 1107 CC_depolarization_ratio 0.039 Constant
FLORTD CGINS-FLORTD-01107 10/11/2017 1107 CC_measurement_wavelength 700 Constant
FLORTD CGINS-FLORTD-01107 10/11/2017 1107 CC_scale_factor_cdom 0.0723
FLORTD CGINS-FLORTD-01107 10/11/2017 1107 CC_scale_factor_chlorophyll_a 0.0118
FLORTD CGINS-FLORTD-01107 10/11/2017 1107 CC_scale_factor_volume_scatter 1.916E-06
FLORTD CGINS-FLORTD-01107 10/11/2017 1107 CC_scattering_angle 124 Constant