Asset: CGINS-FLORTK-01466

Type
Sensor
Mobile
0
Description of Equipment
3-Wavelength Fluorometer: FLORT Series K
Manufacturer
WET Labs
Model
ECO Triplet
Manufacturer Serial No
1466
Firmware Version
Acquisition Date
Original Cost
$0.00
Comments
Deployment Cruise Reference Designator Deployment Number Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
AR8 CP02PMUO-WFP01-04-FLORTK000 8 10/02/2016 06/07/2017 CGMCP-02PMUO-00008 CGVEH-CWFPCP-99105 CGINS-FLORTK-01466 39.9394 -70.7708 423 447
AR24 CP04OSPM-WFP01-04-FLORTK000 8 11/09/2017 04/09/2018 CGMCP-04OSPM-00008 CGVEH-CWFPCP-99105 CGINS-FLORTK-01466 39.9347 -70.8802 409 455
AR31 CP04OSPM-WFP01-04-FLORTK000 10 11/06/2018 04/22/2019 CGMCP-04OSPM-00010 CGVEH-CWFPCP-99105 CGINS-FLORTK-01466 39.9366 -70.8793 407 453
AR39 CP04OSPM-WFP01-04-FLORTK000 12 10/13/2019 06/08/2020 CGMCP-04OSPM-00012 CGVEH-CWFPCP-99105 CGINS-FLORTK-01466 39.9356 -70.8803 405 451

No notes yet.

Class Asset UID Start Date Serial Name Value Notes
FLORTK CGINS-FLORTK-01466 06/27/2016 1466 CC_angular_resolution 1.076
FLORTK CGINS-FLORTK-01466 06/27/2016 1466 CC_dark_counts_cdom 46.0
FLORTK CGINS-FLORTK-01466 06/27/2016 1466 CC_dark_counts_chlorophyll_a 49.0
FLORTK CGINS-FLORTK-01466 06/27/2016 1466 CC_dark_counts_volume_scatter 43.0
FLORTK CGINS-FLORTK-01466 06/27/2016 1466 CC_depolarization_ratio 0.039
FLORTK CGINS-FLORTK-01466 06/27/2016 1466 CC_measurement_wavelength 700.0
FLORTK CGINS-FLORTK-01466 06/27/2016 1466 CC_scale_factor_cdom 0.0906
FLORTK CGINS-FLORTK-01466 06/27/2016 1466 CC_scale_factor_chlorophyll_a 0.0121
FLORTK CGINS-FLORTK-01466 06/27/2016 1466 CC_scale_factor_volume_scatter 3.026e-06
FLORTK CGINS-FLORTK-01466 06/27/2016 1466 CC_scattering_angle 124.0
FLORTK CGINS-FLORTK-01466 07/25/2017 1466 CC_angular_resolution 1.076
FLORTK CGINS-FLORTK-01466 07/25/2017 1466 CC_dark_counts_cdom 50
FLORTK CGINS-FLORTK-01466 07/25/2017 1466 CC_dark_counts_chlorophyll_a 51
FLORTK CGINS-FLORTK-01466 07/25/2017 1466 CC_dark_counts_volume_scatter 50
FLORTK CGINS-FLORTK-01466 07/25/2017 1466 CC_depolarization_ratio 0.039
FLORTK CGINS-FLORTK-01466 07/25/2017 1466 CC_measurement_wavelength 700
FLORTK CGINS-FLORTK-01466 07/25/2017 1466 CC_scale_factor_cdom 0.0941
FLORTK CGINS-FLORTK-01466 07/25/2017 1466 CC_scale_factor_chlorophyll_a 0.0115
FLORTK CGINS-FLORTK-01466 07/25/2017 1466 CC_scale_factor_volume_scatter 3.351E-06
FLORTK CGINS-FLORTK-01466 07/25/2017 1466 CC_scattering_angle 124
FLORTK CGINS-FLORTK-01466 06/28/2018 1466 CC_angular_resolution 1.076
FLORTK CGINS-FLORTK-01466 06/28/2018 1466 CC_dark_counts_cdom 50
FLORTK CGINS-FLORTK-01466 06/28/2018 1466 CC_dark_counts_chlorophyll_a 50
FLORTK CGINS-FLORTK-01466 06/28/2018 1466 CC_dark_counts_volume_scatter 49
FLORTK CGINS-FLORTK-01466 06/28/2018 1466 CC_depolarization_ratio 0.039
FLORTK CGINS-FLORTK-01466 06/28/2018 1466 CC_measurement_wavelength 700
FLORTK CGINS-FLORTK-01466 06/28/2018 1466 CC_scale_factor_cdom 0.0849
FLORTK CGINS-FLORTK-01466 06/28/2018 1466 CC_scale_factor_chlorophyll_a 0.0111
FLORTK CGINS-FLORTK-01466 06/28/2018 1466 CC_scale_factor_volume_scatter 3.404E-06
FLORTK CGINS-FLORTK-01466 06/28/2018 1466 CC_scattering_angle 124
FLORTK CGINS-FLORTK-01466 06/17/2019 1466 CC_angular_resolution 1.076 source_file FLORT-K_BBFL2_SN_1466_Calibration_2019-06-17.zip > BBFL2-1466 Charsheet.pdf
FLORTK CGINS-FLORTK-01466 06/17/2019 1466 CC_dark_counts_cdom 47
FLORTK CGINS-FLORTK-01466 06/17/2019 1466 CC_dark_counts_chlorophyll_a 48
FLORTK CGINS-FLORTK-01466 06/17/2019 1466 CC_dark_counts_volume_scatter 49
FLORTK CGINS-FLORTK-01466 06/17/2019 1466 CC_depolarization_ratio 0.039
FLORTK CGINS-FLORTK-01466 06/17/2019 1466 CC_measurement_wavelength 700
FLORTK CGINS-FLORTK-01466 06/17/2019 1466 CC_scale_factor_cdom 0.0811
FLORTK CGINS-FLORTK-01466 06/17/2019 1466 CC_scale_factor_chlorophyll_a 0.0139
FLORTK CGINS-FLORTK-01466 06/17/2019 1466 CC_scale_factor_volume_scatter 3.387E-06
FLORTK CGINS-FLORTK-01466 06/17/2019 1466 CC_scattering_angle 124