Hydrogen Sensor

Reference Designator
CE02SHSM-SBD12-03-HYDGN0000
Review Status
Engineering
Note
Depth
0m
Class
HYDGN (Hydrogen Sensor)
Make / Model
RKI Instruments / M2A transmitters

Dataset Reviews

No reviews found.

System Annotations

Metadata Start Date End Date Comment
CE02SHSM-SBD12-03-HYDGN0000
8/12/19, 4:30 PM 8/27/19, 2:30 PM

Disabled due to low-power conditions on the mooring

Id: 1705 By: wingardc
Flag: not_operational Exclude: No

CE02SHSM-SBD12-03-HYDGN0000
Method: telemetered
10/22/19, 6:30 PM

The hydrogen sensor values are bouncing around between 0 and 2 percent in a manner that does not look real. Given that the other sensor in the well is reading as expected with stable values, we are labeling this data as suspect.

Id: 1756 By: wingardc
Flag: suspect Exclude: No

CE02SHSM-SBD12
Method: telemetered
1/13/20, 1:45 PM

During a large storm event on 2020-01-11, power from the wind turbines was lost. This is the primary means of recharging the battery system on the mooring. With the loss of recharging power, we have had to implement a conservative power model. These systems and instruments have been disabled for the foreseeable future, and no further data will collected from them.

Id: 1900 By: wingardc
Flag: not_operational Exclude: No

Review Notes

No notes yet.

New Note