Method | Data Stream | Content | Type | |
---|---|---|---|---|
streamed | ctdpf_optode_calibration_coefficients | Optode Calibration Data | Report M2M | Engineering |
streamed | ctdpf_optode_configuration | Optode Configuration Data | Report M2M | Engineering |
streamed | ctdpf_optode_hardware | Optode Hardware Data | Report M2M | Engineering |
streamed | ctdpf_optode_sample | Optode Data Products | Report M2M Stats | Science |
streamed | ctdpf_optode_settings | Optode Settings Data | Report M2M | Engineering |
streamed | ctdpf_optode_status | Optode Status Data | Report M2M | Engineering |
Deployment | Cruise | Start Date | Stop Date | Mooring Asset | Node Asset | Sensor Asset | Latitude | Longitude | Deployment Depth | Water Depth |
---|---|---|---|---|---|---|---|---|---|---|
1 Review | TN-313 | 08/30/2014 | 08/02/2015 | ATAPL-69839-002-0102 | ATOSU-66662-00006 | 44.3741 | -124.957 | 194 | 580 | |
2 Review | TN-326 | 08/03/2015 | 07/18/2016 | ATAPL-69839-002-0105 | ATOSU-66662-00014 | 44.3741 | -124.956 | 194 | 580 | |
3 Review | SKQ201610S | 07/19/2016 | 07/28/2017 | ATAPL-69839-002-0105 | ATOSU-66662-00006 | 44.3741 | -124.956 | 194 | 580 | |
4 Review | RR1713 | 07/29/2017 | 07/17/2018 | ATAPL-69839-002-0105 | ATOSU-66662-00014 | 44.3741 | -124.956 | 194 | 580 | |
5 Review | RR1811 | 07/17/2018 | 06/13/2019 | ATAPL-69839-002-0102 | ATOSU-66662-00006 | 44.3741 | -124.956 | 194 | 580 | |
6 Review | AT-42-12 | 06/14/2019 | ATAPL-69839-002-0102 | ATOSU-66662-00014 | 44.3741 | -124.956 | 194 | 580 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CE04OSPS-PC01B-4A-CTDPFA109 |
Annotation IDs 1031, 1032, 1036 should be investigated and revised. By Lori Garzio, on 4/4/19 |
||
CE04OSPS-PC01B-4A-CTDPFA109 |
Annotation ID 181 and 221 are duplicates. By Lori Garzio, on 4/4/19 |
||
CE04OSPS-PC01B-4A-CTDPFA109 Deployment: 1 |
8/30/14, 9:16 AM | 8/2/15, 12:00 AM |
The deployment depth from asset management indicates that the instrument was deployed at 194 m, however the reported pressure data are around 213 dbar. This should be checked and either the deployment depth in asset management should be updated or the data should be annotated until the issue is fixed. Excluding from summary data ranges. By Lori Garzio, on 4/4/19 |
CE04OSPS-PC01B-4A-CTDPFA109 Deployment: 2 |
8/3/15, 5:41 AM | 7/18/16, 12:00 AM |
Annotation ID 205: "Due to errors during vendor calibration, a calibration offset (CC_offset) of -5.43 is being applied during the on-demand creation of the L1 Seawater Pressure (dbar) data product from this instrument." - it doesn't look like this offset is actually being applied as the pressure is still 5 dbar deeper than the two later deployments (199 dbar) and the deployment depth from asset management (listed at 194 dbar). This issue needs to be investigated. Excluding from summary data ranges. Annotation ID 20 should be deleted (it's a duplicate of ID 208, but 208 has more info) By Lori Garzio, on 4/4/19 |
CE04OSPS-PC01B-4A-CTDPFA109 Deployment: 3 |
7/19/16, 8:00 AM | 7/28/17, 12:00 AM |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CE04OSPS-PC01B-4A-CTDPFA109 |
11/4/14, 11:05 AM | 11/5/14, 2:25 PM |
Note: Data gap under investigation Id: 1031 By: knuth |
CE04OSPS-PC01B-4A-CTDPFA109 |
11/5/14, 7:25 PM | 1/8/15, 1:28 PM |
Note: Data gap under investigation Id: 1032 By: knuth |
CE04OSPS |
12/7/14, 2:45 PM | 12/15/14, 7:00 PM |
Note: PFE down. HVPS1 MOV explosion, 800A breaker tripped, investigation and restoration Id: 1033 By: knuth |
CE04OSPS |
1/7/15, 2:32 AM | 1/7/15, 3:06 AM |
Note: PNWGP Portland <-> Seattle outage Id: 1034 By: knuth |
CE04OSPS |
1/30/15, 7:00 PM | 2/3/15, 7:00 PM |
Note: Intermittent partial data loss due to storage drive problems at OTB Id: 1035 By: knuth |
CE04OSPS-PC01B-4A-CTDPFA109 Method: streamed Stream: ctdpf_optode_sample |
3/7/15, 6:06 PM | 3/9/15, 3:39 AM |
Data gap under investigation
Id: 1036
By: knuth
|
CE04OSPS |
3/21/15, 10:10 AM | 3/22/15, 12:20 AM |
Note: Intermittent data gaps. PNWGP outage due to City of Seattle fiber cable work Id: 1037 By: knuth |
CE04OSPS |
6/12/15, 8:00 PM | 6/15/15, 12:30 PM |
Note: Intermittent data gaps. Network issues due to fire that damaged fibers between Portland and Seattle Id: 1038 By: knuth |
CE04OSPS-PC01B-4A-CTDPFA109 |
6/30/15, 8:00 PM | 8/5/15, 8:00 PM |
Note: Instrument operational up to July 1 2015. Unknown status between July 1 and Aug 6 2015 Id: 1039 By: knuth |
CE04OSPS-PC01B-4A-CTDPFA109 Method: streamed Stream: ctdpf_optode_sample |
8/3/15, 1:41 AM | 7/17/16, 8:00 PM |
Due to errors during vendor calibration, a calibration offset (CC_offset) of -5.43 is being applied during the on-demand creation of the L1 Seawater Pressure (dbar) data product from this instrument. For more information please contact help@oceanobservatories.org. Id: 205 By: friedrich.knuth |
CE04OSPS-PC01B-4A-CTDPFA109 Method: streamed Stream: ctdpf_optode_sample |
8/3/15, 7:59 PM | 8/5/15, 2:47 AM |
Parameters: oxygen, ctd_tc_oxygen, dissolved_oxygen. Values are too high at start of deployment and exceeded 400 umol L-1 (kg-1 for DO). Redmine 12297
Id: 1041
By: knuth
|
CE04OSPS |
8/28/15, 8:00 PM | 8/28/15, 8:30 PM |
Note: Intermittent data gaps. Outage during major utility power failure in Seattle Id: 1042 By: knuth |
CE04OSPS |
1/7/16, 1:10 AM | 1/7/16, 1:52 AM |
Note: Four 1-minute outages between Portland and Seattle due to maintenance Id: 1043 By: knuth |
CE04OSPS |
3/10/16, 6:06 PM | 3/11/16, 4:30 AM |
Note: Fiber break between Portland and Seattle Id: 1044 By: knuth |
CE04OSPS |
5/20/16, 12:33 PM | 5/20/16, 2:04 PM |
Note: Fiber break between Portland and Pacific City Id: 1047 By: knuth |
CE04OSPS |
7/11/16, 10:53 PM | 7/11/16, 11:51 PM |
Note: Unexplained loss of power at Pittock Building in Portland Id: 1048 By: knuth |
CE04OSPS-PC01B-4A-CTDPFA109 Method: streamed Stream: ctdpf_optode_sample |
7/18/16, 8:51 AM | 7/28/17, 8:13 AM |
The oxygen products from this instrument are suspect, due to errors during vendor calibration. Until a correction can be applied, the oxygen data from this time range should not be used.
Id: 200
By: friedrich.knuth
|
CE04OSPS-PC01B-4A-CTDPFA109 Method: streamed Stream: ctdpf-optode-sample |
7/18/16, 8:00 PM | 7/18/17, 8:00 PM |
The derived O2 products (L1 Temperature Compensated and L2 Salinity Corrected Dissolved Oxygen) are suspect, due to errors during vendor calibration. Until a correction can be applied, they should not be used from 7/19/16 onwards. Id: 12 |
CE04OSPS-PC01B-4A-CTDPFA109 Method: streamed Stream: ctdpf_optode_sample |
7/19/16, 4:00 AM | 7/27/17, 8:00 PM |
Due to errors during vendor calibration, a calibration offset (CC_offset) of -19.55 is being applied during the on-demand creation of the L1 Seawater Pressure (dbar) data product from this instrument. For more information please contact help@oceanobservatories.org. Id: 206 By: friedrich.knuth |
CE04OSPS |
12/17/16, 1:00 PM | 12/17/16, 2:00 PM |
Note: Corvalis data center lost power Id: 1050 By: knuth |
CE04OSPS |
12/21/16, 8:50 PM | 12/23/16, 7:44 AM |
Note: Fiber break in Portland due to train crash Id: 1051 By: knuth |
CE04OSPS |
1/8/17, 2:58 PM | 1/8/17, 4:41 PM |
Note: Network outage during major Seattle utility power failure Id: 1052 By: knuth |
CE04OSPS |
1/9/17, 1:30 PM | 1/9/17, 3:25 PM |
Note: Lightning strike in Pacific City led to isolation of both cable lines from shore station equipment, when Power Feed Equipment High Voltage Opening Switches operated. All deployed infrastructure went offline. Id: 1053 By: knuth |
CE04OSPS-PC01B-4A-CTDPFA109 Method: streamed Stream: ctdpf_optode_sample |
1/9/17, 3:25 PM | 1/10/17, 8:02 PM |
CTD offline because of power interruption caused by lightning strike in Pacific City in close proximity to shore station.
Id: 1055
By: knuth
|
CE04OSPS |
2/7/17, 8:00 AM | 2/7/17, 10:00 AM |
Note: Intermittent data gaps. Outage during PNWGP 1-hour router-maintenance Id: 1057 By: knuth |
CE04OSPS |
2/15/17, 9:43 AM | 2/15/17, 12:16 PM |
Note: Power Feed Equipment failure during major utility power issues related to lightning strike on Pacific City electrical sub-station. All deployed infrastructure went offline. Power was restored on February 16. No hardware issue subsea was identified. Id: 1058 By: knuth |
CE04OSPS-PC01B-4A-CTDPFA109 Method: streamed Stream: ctdpf_optode_sample |
2/15/17, 9:43 AM | 2/15/17, 12:16 PM |
Power Feed Equipment failure during major utility power issues related to lightning strike on Pacific City electrical sub-station. All deployed infrastructure went offline. Power was restored on February 16. No hardware issue subsea was identified.
Id: 1061
By: knuth
|
CE04OSPS-PC01B-4A-CTDPFA109 Method: streamed Stream: ctdpf_optode_sample |
2/15/17, 12:16 PM | 2/16/17, 6:12 PM |
CTD offline because of power interruption caused by lightning strike in Pacific City in close proximity to shore station.
Id: 1062
By: knuth
|
CE04OSPS |
9/16/17, 7:30 AM | 9/16/17, 8:13 AM |
Data are suspect during this time range, due to the following event: On Saturday, September 16, 2017 at around 12:15 GMT, the CA Shallow Profiler at Endurance (CE04OSPS) went offline due to an overcurrent power event. Initial investigation indicated external aggression on one of the two anchor legs, pulling the platform that is normally fixed at 200m below the surface to 400m, and then rose to 100m before communications were lost. No data products are expected from CE04OSPS until the platform is re-deployed. For more information, please contact help@oceanobservatories.org
Id: 181
By: friedrich.knuth
|
CE04OSPS Method: streamed |
9/16/17, 8:13 AM | 7/17/18, 11:00 AM |
On Saturday, September 16, 2017 at around 12:15 GMT, the CA Shallow Profiler at Endurance (CE04OSPS) went offline due to an overcurrent power event. Initial investigation indicated external aggression on one of the two anchor legs, pulling the platform that is normally fixed at 200m below the surface to 400m, and then rose to 100m before communications were lost. No data products are expected from CE04OSPS until the platform is re-deployed. For more information, please contact help@oceanobservatories.org
Id: 221
By: friedrich.knuth
|
CE04OSPS |
8/22/18, 1:00 PM | 8/24/18, 4:00 PM |
On Wednesday Aug 22 2018, an automatic protective shutdown of primary power to the OOI Cabled Array occurred during installation of a new chiller system. Power was restored on Aug 24. Due to loss of power to the Cabled Array marine infrastructure, data were not collected by the instruments.
Id: 1485
By: lgarzio
|