Method | Data Stream | Content | Type | |
---|---|---|---|---|
recovered_host | velpt_ab_dcl_diagnostics_metadata_recovered | Diagnostics Metadata | Report M2M | Engineering |
recovered_host | velpt_ab_dcl_diagnostics_recovered | Diagnostics Data | Report M2M | Engineering |
recovered_host | velpt_ab_dcl_instrument_recovered | Data Products | Report M2M Stats | Science |
recovered_inst | velpt_ab_diagnostics_metadata_recovered | Diagnostics Metadata | Report M2M | Engineering |
recovered_inst | velpt_ab_diagnostics_recovered | Diagnostics Data | Report M2M | Engineering |
recovered_inst | velpt_ab_instrument_metadata_recovered | Metadata | Report M2M | Engineering |
recovered_inst | velpt_ab_instrument_recovered | Data Products | Report M2M Stats | Science |
telemetered | velpt_ab_dcl_diagnostics | Diagnostics Data | Report M2M | Engineering |
telemetered | velpt_ab_dcl_diagnostics_metadata | Diagnostics Metadata | Report M2M | Engineering |
telemetered | velpt_ab_dcl_instrument | Data Products | Report M2M Stats | Science |
Deployment | Cruise | Start Date | Stop Date | Mooring Asset | Node Asset | Sensor Asset | Latitude | Longitude | Deployment Depth | Water Depth |
---|---|---|---|---|---|---|---|---|---|---|
1 Review | KN-214 | 11/21/2013 | 04/18/2014 | CGMCP-01CNSM-00001 | CGINS-VELPTA-08550 | 40.1368 | -70.7698 | 132.5 | 133.5 | |
2 Review | KN-224 | 12/13/2014 | 12/15/2014 | CGMCP-01CNSM-00002 | CGINS-VELPTA-11386 | 40.1339 | -70.7789 | 134 | 135 | |
3 Review | AT-27 | 05/07/2015 | 10/23/2015 | CGMCP-01CNSM-00003 | CGINS-VELPTA-11386 | 40.1402 | -70.7713 | 134 | 135 | |
5 Review | AR-04 | 05/13/2016 | 10/13/2016 | CGMCP-01CNSM-00005 | CGINS-VELPTA-11397 | 40.1404 | -70.7713 | 133 | 134 | |
6 Review | AR-08 | 10/13/2016 | 06/09/2017 | CGMCP-01CNSM-00006 | CGINS-VELPTA-12203 | 40.1334 | -70.7785 | 133 | 134 | |
7 Review | AR-18 | 06/09/2017 | 11/01/2017 | CGMCP-01CNSM-00007 | CGINS-VELPTA-08532 | 40.1398 | -70.7711 | 133 | 134 | |
8 Review | AR-24 | 10/29/2017 | 03/29/2018 | CGMCP-01CNSM-00008 | CGINS-VELPTA-11386 | 40.1334 | -70.7783 | 133 | 134 | |
9 Review | AR-28 | 03/24/2018 | 10/29/2018 | CGMCP-01CNSM-00009 | CGINS-VELPTA-11417 | 40.1398 | -70.7713 | 133 | 134 | |
10 Review | AR-31 | 10/30/2018 | 04/07/2019 | CGMCP-01CNSM-00010 | CGINS-VELPTA-11402 | 40.1334 | -70.7777 | 133 | 134 | |
11 Review | AR-34 | 04/06/2019 | 09/26/2019 | CGMCP-01CNSM-00011 | CGINS-VELPTA-11377 | 40.1401 | -70.7714 | 132 | 133 | |
12 Review | AR-39 | 09/27/2019 | CGMCP-01CNSM-00012 | CGINS-VELPTA-11397 | 40.1332 | -70.7783 | 132 | 133 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CP01CNSM-MFD35-04-VELPTA000 |
recovered_inst data are not available for download from deployments 3 and 5 - the raw data files are available according to the ingest csv. The data should be ingested or annotated to indicate why they are not available. By Lori Garzio, on 6/5/19 |
||
CP01CNSM Deployment: 2 |
Annotation ID 709 "Short deployment due to the fuel cell not functioning correctly" should be updated to indicate that this refers to deployment 2, and data aren't expected from most instruments for this time period. By Lori Garzio, on 3/22/19 |
||
CP01CNSM-MFD35-04-VELPTA000 Deployment: 6 |
10/13/16, 6:36 PM | 6/9/17, 4:05 PM |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CP01CNSM-MFD35-04-VELPTA000 |
11/21/13, 1:15 PM |
According to the manufacturer, data are suspect when the instrument is tilted more than 20 degrees (measured by pitch and roll). Id: 813 By: lgarzio |
|
CP01CNSM-MFD35-04-VELPTA000 |
11/21/13, 1:15 PM | 4/17/14, 8:00 PM |
Recovered host data are not available. Id: 495 By: leila |
CP01CNSM |
2/16/14, 7:00 PM | 4/17/14, 8:00 PM |
Surface buoy exploded due to hydrogen build-up in well.
Id: 103
By: swhite
|
CP01CNSM |
12/13/14, 1:47 PM | 12/15/14, 3:58 PM |
Deployment 2: Short deployment due to the fuel cell not functioning correctly. No data expected. Id: 709 By: cdobson |
CP01CNSM-MFD35-04-VELPTA000 |
12/13/14, 1:47 PM | 12/15/14, 3:58 PM |
Data not recoverable. Id: 507 By: leila |
CP01CNSM-MFD35 |
5/21/15, 8:00 PM | 10/23/15, 3:40 PM |
Deployment 3: Seafloor Multi-Function Node failed to send data via telemetry. Id: 571 By: cdobson |
CP01CNSM-MFD35-04-VELPTA000 |
10/13/16, 2:36 PM | 6/9/17, 12:05 PM |
No recovered instrument data are available. Id: 547 By: leila |
CP01CNSM-MFD35 |
1/21/17, 7:00 PM | 6/9/17, 12:05 PM |
Multi-function Node was shut down due to low power.
Id: 104
By: lgarzio
|
CP01CNSM-MFD35 |
12/20/17, 3:00 AM | 3/24/18, 5:00 PM |
Deployment 8: Multi-Function Node was disabled due to shorting in the power.
Id: 336
By: leila
|
CP01CNSM-MFD35 Method: telemetered |
3/28/18, 6:59 AM | 10/29/18, 9:48 PM |
Deployment 9: An unexpected ground fault had occurred. Instruments with batteries will continue to collect data.
Id: 1363
By: leila
|
CP01CNSM-MFD35 Method: telemetered |
10/30/18, 9:00 AM | 4/7/19, 2:08 PM |
Deployment 10: Power to MFN was lost immediately after deployment. There will be no telemetered data for any MFN instruments for this deployment. Most impacted instruments will continue to collect data on battery power and be available as recovered data.
Id: 1562
By: cdobson
|
CP01CNSM-MFD35 |
9/26/19, 8:00 PM |
Deployment 12: Power issue hinders telemtered data transfer from all MFN instruments. Data from all internally logging instruments will be available on recovery. Id: 1741 By: cdobson |