Method | Data Stream | Content | Type | |
---|---|---|---|---|
recovered_host | parad_m_glider_recovered | Data Products | Report M2M Stats | Science |
telemetered | parad_m_glider_instrument | Data Products | Report M2M Stats | Science |
Deployment | Cruise | Start Date | Stop Date | Mooring Asset | Node Asset | Sensor Asset | Latitude | Longitude | Deployment Depth | Water Depth |
---|---|---|---|---|---|---|---|---|---|---|
1 Review | KN-222 | 10/07/2014 | 01/11/2015 | CGVCP-05MOAS-00000 | CGVEH-GLDRCP-00380 | CGINS-PARADM-50159 | 39.8253 | -70.5827 | 1000 | 1000 |
2 Review | SI20150722 | 07/23/2015 | 10/15/2015 | CGVCP-05MOAS-00000 | CGVEH-GLDRCP-00380 | CGINS-PARADM-50159 | 40.0949 | -70.6554 | 1000 | 1000 |
3 Review | AR-08 | 10/11/2016 | 01/16/2017 | CGVCP-05MOAS-00000 | CGVEH-GLDRCP-00380 | CGINS-PARADM-50195 | 39.8362 | -70.7289 | 1000 | 1000 |
4 Review | AR-18 | 06/07/2017 | 08/17/2017 | CGVCP-05MOAS-00000 | CGVEH-GLDRCP-00380 | CGINS-PARADM-50146 | 39.8393 | -70.7304 | 1000 | 1000 |
5 Review | AR-24 | 11/01/2017 | 11/24/2017 | CGVCP-05MOAS-00000 | CGVEH-GLDRCP-00380 | CGINS-PARADM-50163 | 39.8504 | -70.7247 | 1000 | 1000 |
6 Review | SI20180126 | 01/27/2018 | 02/03/2018 | CGVCP-05MOAS-00000 | CGVEH-GLDRCP-00380 | CGINS-PARADM-50163 | 39.8615 | -70.3956 | 1000 | 1000 |
7 Review | AR-31 | 10/25/2018 | 10/27/2018 | CGVCP-05MOAS-00000 | CGVEH-GLDRCP-00380 | CGINS-PARADM-50277 | 39.875 | -70.8847 | 1000 | 1000 |
8 Review | TS20191212 | 12/12/2019 | 03/02/2020 | CGVCP-05MOAS-00000 | CGVEH-GLDRCP-00380 | CGINS-PARADM-50151 | 39.9149 | -70.6661 | 1000 | 1000 |
9 Review | TS20200613 | 06/13/2020 | CGVCP-05MOAS-00000 | CGVEH-GLDRCP-00380 | CGINS-PARADM-50151 | 39.9285 | -70.3721 | 1000 | 1000 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CP05MOAS |
Bad altimeter pings are apparent in many deployments of the coastal gliders. A few example plots are attached - m_water_depth plotted as semi-transparent bathymetry. By Lori Garzio, on 5/10/19 |
||
CP05MOAS |
Glider optodes typically exhibit a sensor lag of 20-25 seconds. Example attached of several segments with consecutive down and up casts for CP05MOAS-GL335-04-DOSTAM000 on 10/26/2015 showing a typical measurement time lag. Profiles should be analyzed for individual time lags and data should be adjusted. OOI doesn't necessarily need to make the adjustment but users should be aware of the issue. By Lori Garzio, on 5/15/19 |
||
CP05MOAS-GL380-05-PARADM000 |
Annotation IDs 1572 and 1573 are duplicates of 1570 and 1571 By Lori Garzio, on 9/4/19 |
||
CP05MOAS-GL380-05-PARADM000 |
99% of the sci_bsipar_par values for deployments 1 and 3 are outside of global ranges. sci_bsipar_par is the unscaled L0 PAR data product. The global ranges for this parameter are the same as for the scaled L1 PAR data product [0.0, 2500.0]. The global range for sci_bsipar_par should be reviewed. By Lori Garzio, on 9/4/19 |
||
CP05MOAS-GL380-05-PARADM000 Deployment: 1 |
|||
CP05MOAS-GL380 Deployment: 2 |
|||
CP05MOAS-GL380-05-PARADM000 Deployment: 4 |
|||
CP05MOAS-GL380-05-PARADM000 Deployment: 5 |
Data are available in the telemetered data stream but are not in the recovered data stream from 2017-11-09T01:12:30 to 2017-11-09T08:07:26. These data should be in the recovered stream. By Lori Garzio, on 9/4/19 |
||
CP05MOAS-GL380 Deployment: 6 |
Short deployment should be annotated By Lori Garzio, on 9/4/19 |
Metadata | Start Date | End Date | Comment |
---|---|---|---|
CP05MOAS-GL380 Method: telemetered |
10/25/18, 4:26 PM | 10/26/18, 10:47 PM |
Glider was deployed for two days before it expereienced a leak and needed to be recovered. No further data expected. Id: 1570 By: cdobson |
CP05MOAS-GL380 Method: recovered_host |
10/25/18, 4:26 PM | 10/26/18, 10:47 PM |
Glider was deployed for two days before it expereienced a leak and needed to be recovered. No further data expected. Id: 1571 By: cdobson |
CP05MOAS-GL380-05-PARADM000 Method: recovered |
10/25/18, 4:26 PM | 10/26/18, 10:47 PM |
Glider was deployed for two days before it expereienced a leak and needed to be recovered. No further data expected. Id: 1572 By: cdobson |
CP05MOAS-GL380-05-PARADM000 Method: recovered_host |
10/25/18, 4:26 PM | 10/26/18, 10:47 PM |
Glider was deployed for two days before it expereienced a leak and needed to be recovered. No further data expected. Id: 1573 By: cdobson |
CP05MOAS-GL380 |
2/21/20, 7:00 AM | 3/2/20, 2:50 AM |
Deployment 8: Science sampling was disabled on this glider on 2/21/2020 to preserve battery power for recovery. No science data are expected after this date. Id: 2011 By: cdobson |