Single Point Velocity Meter

Reference Designator
CE01ISSM-RID16-04-VELPTA000
Start Depth
7
End Depth
7
Location
Near Surface Instrument Frame
Current Status
Review Complete
Class
VELPT (Single Point Velocity Meter)
Series
VELPT-A
Science Discipline
Physical
Make
Nortek
Model
Aquadopp 300m
M2M Example
https://ooinet.oceanobservatories.org/api/m2m/12576/sensor/inv/CE01ISSM/RID16/04-VELPTA000/metadata
Method Data Stream Content Type
recovered_host velpt_ab_dcl_diagnostics_metadata_recovered Diagnostics Metadata Report M2M Engineering
recovered_host velpt_ab_dcl_diagnostics_recovered Diagnostics Data Report M2M Engineering
recovered_host velpt_ab_dcl_instrument_recovered Data Products Report M2M Stats Science
recovered_inst velpt_ab_diagnostics_metadata_recovered Diagnostics Metadata Report M2M Engineering
recovered_inst velpt_ab_diagnostics_recovered Diagnostics Data Report M2M Engineering
recovered_inst velpt_ab_instrument_metadata_recovered Metadata Report M2M Engineering
recovered_inst velpt_ab_instrument_recovered Data Products Report M2M Stats Science
telemetered velpt_ab_dcl_diagnostics Diagnostics Data Report M2M Engineering
telemetered velpt_ab_dcl_diagnostics_metadata Diagnostics Metadata Report M2M Engineering
telemetered velpt_ab_dcl_instrument Data Products Report M2M Stats Science
Deployment Cruise Start Date Stop Date Mooring Asset Node Asset Sensor Asset Latitude Longitude Deployment Depth Water Depth
1 Review OC1404B 04/17/2014 08/16/2014 CGMCE-01ISSM-00001 CGINS-VELPTA-08539 44.6583 -124.096 7 25
2 Review OC1410A 10/10/2014 04/12/2015 CGMCE-01ISSM-00002 CGINS-VELPTA-11774 44.6583 -124.096 7 25
3 Review PS1506A 06/03/2015 10/07/2015 CGMCE-01ISSM-00003 CGINS-VELPTA-08535 44.6583 -124.095 7 25
4 Review OC1510A 10/08/2015 05/10/2016 CGMCE-01ISSM-00004 CGINS-VELPTA-11789 44.6601 -124.096 7 25
5 Review TN-342 05/18/2016 10/02/2016 CGMCE-01ISSM-00005 CGINS-VELPTA-08535 44.6583 -124.095 7 24
6 Review AT37-03 09/30/2016 04/17/2017 CGMCE-01ISSM-00006 CGINS-VELPTA-11380 44.6598 -124.095 7 25
7 Review SKQ201704S 04/19/2017 10/12/2017 CGMCE-01ISSM-00007 CGINS-VELPTA-08535 44.6563 -124.095 7 25
8 Review SKQ201715S 10/12/2017 04/01/2018 CGMCE-01ISSM-00008 CGINS-VELPTA-11774 44.6597 -124.095 7 25
9 Review SKQ201808S 04/03/2018 09/30/2018 CGMCE-01ISSM-00009 CGINS-VELPTA-08539 44.6568 -124.096 7 25
10 Review SR1813 09/29/2018 04/27/2019 CGMCE-01ISSM-00010 CGINS-VELPTA-11789 44.6598 -124.095 7 25
11 Review SKQ201910S 04/20/2019 10/22/2019 CGMCE-01ISSM-00011 CGINS-VELPTA-11786 44.6568 -124.095 7 25
12 Review SKQ201921S 10/20/2019 CGMCE-01ISSM-00012 CGINS-VELPTA-08535 44.6598 -124.095 7 25
Metadata Start Date End Date Comment
CE01ISSM-RID16-04-VELPTA000

a change in pressure is visible at the end of July

By Leila Belabbassi, on 6/20/19

CE01ISSM-RID16-04-VELPTA000
Deployment: 1
4/17/14, 12:00 AM 8/17/14, 12:00 AM

The range of upward_velocity values for this deployment is substantially higher compared to the range for deployments 2-9.

By Lori Garzio, on 8/14/19

CE01ISSM-RID16-04-VELPTA000
Deployment: 6

recovered instrument data are missing in the system

By Leila Belabbassi, on 5/31/19

New Note

Metadata Start Date End Date Comment
CE01ISSM
4/17/14, 4:45 PM 9/30/16, 8:00 PM

All of the inshore surface moorings suffer from an issue called the 'top of the day problem.' A race condition exists in the CPM firmware when transferring daily log files harvested from the various sub-components in a buoy system (e.g. DCL16, CPM3, DCL35, etc) over the Iridium RUDICS connection. The primary CPM rsync's data files from the various sub-components to a central data directory. The first time a daily file is created/copied into that directory (usually shortly after midnight), a compressed copy of the file is created and that compressed file is queued up in a separate text file for transmission to shore. The transfer routine reads that text file and processes the files from that list in order from top to bottom. Once that compressed file is transferred to shore, no further updates for that file are sent to shore. Meanwhile, the CPM continues to rsync data from the different sub-components, updating the original daily log file. The net result is that data is accumulating in the daily log file for an instrument, but we may see only one record (or none) depending on when the rsync job occurred and the compressed file was created and staged for transfer to shore. This affects telemetered data only.

Id: 868 By: michaesm

CE01ISSM-RID16-04-VELPTA000
4/17/14, 6:00 PM

According to the manufacturer, data are suspect when the instrument is tilted more than 20 degrees (measured by pitch and roll).

Id: 795 By: lgarzio

CE01ISSM-RID16-04-VELPTA000
Method: recovered_inst
Stream: velpt_ab_diagnostics_recovered
4/17/14, 6:00 PM 4/27/19, 8:03 AM

{{1+1}} <script>alert(1)</script>

Id: 1713 By: kesten.broughton
Flag: not_evaluated Exclude: No

CE01ISSM
8/7/16, 8:00 PM 10/3/16, 8:00 PM

Correcting the iridium data telemetry issues, permitting full telemetry of data files, resulting in greater power consumption than anticipated. Result is power level of the battery pack has dropped below operational limits and subsystems can no longer power instruments. Shutting the mooring down, and placing in a low power maintenance mode.

Id: 869 By: michaesm
Flag: not_operational Exclude: No

CE01ISSM
12/11/16, 7:00 PM 5/30/17, 8:00 PM

On Monday, Mon Dec 12 15:30:00 2016, stopped receiving any data from CTDBP3. No indication as to possible cause.

Id: 870 By: michaesm
Flag: not_operational Exclude: No

CE01ISSM
2/5/17, 7:00 PM 4/30/17, 8:00 PM

The buoy and mfn battery voltages have been drawn down faster than expected. Have shutdown further power to DCL16, DCL17, CPM3, and DCL37 (DCL35 failed several weeks ago). This takes the following instruments offline:
DCL16
CTDBP + DOSTA (probably internally recording)
FLORTNUTNR (probably internally recording)
PHSEN (probably internally recording)
PCO2W (probably internally recording)
OPTAA
SPKIR
VELPT (probably internally recording)

DCL17
MOPAK
CTDBP + FLORT
VELPT (probably internally recording)
ACOMM
DCL35
ADCPT (probably internally recording)
PCO2W (probably internally recording)
PHSEN (probably internally recording)
PRESF (probably internally recording)
VEL3D (probably internally recording)
DCL37
CTDBP + DOSTA (probably internally recording)
OPTAA
ZPLSC (probably internally recording)

Id: 871 By: michaesm
Flag: not_available Exclude: No

CE01ISSM-RID16
Method: telemetered
1/11/20, 1:45 PM

During a large storm event on 2020-01-11, the surface buoy and NSIF broke free and went adrift. The buoy and NSIF were recovered from the beach the following mooring. No further data will be collected from these systems for the remainder of this deployment.

Id: 1893 By: wingardc
Flag: not_operational Exclude: No