    CP02PMCO-WFP01-04-FLORTK000
    Deployment: 8
    9/10/17, 12:00 AM 11/7/17, 12:00 AM

    suspect data profiles

    By Leila Belabbassi, on 3/25/19

    CP02PMCO-WFP01-04-FLORTK000
    Deployment: 9
    1/1/18, 12:00 AM 4/11/18, 12:00 AM

    suspect data profiles

    By Leila Belabbassi, on 3/25/19

    CP01CNSM-MFD37-03-CTDBPD000
    Deployment: 7
    8/30/17, 12:00 AM 11/1/17, 8:33 PM

    Annotation ID 107 should be updated to span the entire time range the instrument was down.

    By Lori Garzio, on 3/25/19

    CP01CNSM
    Deployment: 2

    Annotation ID 709 "Short deployment due to the fuel cell not functioning correctly" should be updated to indicate that this refers to deployment 2, and data aren't expected from most instruments for this time period.

    By Lori Garzio, on 3/22/19

    CP01CNSM-MFD37

    Annotation IDs 1564 and 1565 are duplicates of annotation ID 1558.

    By Lori Garzio, on 3/25/19

    CP02PMCO-WFP01-04-FLORTK000

    the pressure_depth parameter is missing global ranges

    By Leila Belabbassi, on 3/25/19

    CP01CNSM-RID27-03-CTDBPC000

    Annotation ID 546 should be removed. Data are available from 10-13-2016 to 11-22-2016. Annotation ID 118 should be updated to include more information regarding the instrument failure, if known.

    By Lori Garzio, on 3/25/19

    CP02PMCO-WFP01-05-PARADK000

    Most invalid data in the PAR datasets are negative values. Is this expected?
    Also, PAR values below 100 or near 120 dbar are unrealistically high. Data quality is suspect (see example plot)

    By Leila Belabbassi, on 3/24/19

    CP02PMCO-WFP01-02-DOFSTK000
    Deployment: 1
    9/15/14, 12:00 AM 9/30/14, 12:00 AM

    suspect data profile

    By Leila Belabbassi, on 3/23/19

    CP02PMCO-WFP01-02-DOFSTK000
    Deployment: 1
    6/30/14, 12:00 AM 7/20/14, 12:00 AM

    suspect data profile

    By Leila Belabbassi, on 3/23/19

    CP02PMCO-WFP01-02-DOFSTK000
    Deployment: 6
    9/4/16, 12:00 AM 9/10/16, 12:00 AM

    suspect data profiles

    By Leila Belabbassi, on 3/24/19

    CP01CNSM-RID27-03-CTDBPC000
    Deployment: 3

    Annotation ID 362 "Instrument failed" is a duplicate of annotation ID 117. Annotation 117 should be updated to indicate that this refers to deployment 3 and no data are expected from this time period.

    By Lori Garzio, on 3/22/19

    CP01CNSM-RID27-03-CTDBPC000

    Sampling rates range from 10 - 900 seconds between deployments. Why is there such a wide range of sampling rates? The deployments that deviate from the sampling plan should be annotated.

    By Lori Garzio, on 3/22/19

    CP02PMCO-WFP01-03-CTDPFK000
    Deployment: 3
    5/13/15, 12:00 AM 5/30/15, 12:00 AM

    suspect profiles at the beginning and end of deployment

    By Leila Belabbassi, on 3/20/19

    GS01SUMO-RID16-02-FLORTD000
    Deployment: 1

    Deployment 1 data gaps should be annotated.

    By Lori Garzio, on 3/22/19

    GS01SUMO-RID16-02-FLORTD000

    pressure_depth (dbar) is an array of fill values in all files. This variable should contain valid pressure data from the collocated CTD.

    By Lori Garzio, on 3/22/19

    GS01SUMO-SBD12-02-FLORTD000
    Deployment: 2
    7/1/16, 12:00 AM 12/12/16, 7:58 AM

    chl-a concentrations towards the end of the deployment are unreasonable, possibly from biofouling? Issue should be investigated and annotated. Excluding from data range summary.

    By Lori Garzio, on 3/22/19

    GS01SUMO-SBD12-02-FLORTD000

    pressure_depth (dbar) is an array of fill values in all files. It's unclear if this variable should contain valid data, or if it's assumed that the pressure is 1 because this instrument is on the surface buoy.

    By Lori Garzio, on 3/22/19

    GS01SUMO-RII11-02-FLORDG032
    Deployment: 2
    1/22/16, 12:00 AM 12/12/16, 7:58 AM

    The missing data should be annotated (the CTD this instrument was attached to failed), and this instrument appeared to fail before the CTD failed (negative values at the end of the data record).

    By Lori Garzio, on 3/22/19

    GS01SUMO-RII11-02-FLORDG033
    Deployment: 2
    5/3/16, 4:00 AM 12/12/16, 7:58 AM

    The missing data should be annotated (the CTD this instrument was attached to failed).

    By Lori Garzio, on 3/22/19